Satish C. Muluk

Satish C. Muluk

Auto-generated profile, based on publicly available information

Satish C. Muluk

Department of Thoracic and Cardiovascular Surgery, Allegheny Health Network, Allegheny General Hospital, Pittsburgh, PA 15212, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2025 in IEEE Access
Verified
Journal Article
Open access
MRMerjulah Roby
Merjulah Roby
Juan C. RestrepoJuan C. Restrepo
Juan C. Restrepo
HPHaehwan Park
Haehwan Park
SMSatish C. Muluk
Satish C. Muluk
MEMark K. Eskandari
Mark K. Eskandari
Ender A FinolEnder A Finol
Ender A Finol
Abdominal Aortic Aneurysm (AAA) is still a socially relevant public health challenge, evidenced by an 82.1% increase in associated fatalities from 1990 to 2019 (with 172,427 deaths in 2019 alone). In a clinical setting, computed tomography angiography (CTA) is the imaging modality of choice for monitoring and/or presurgical planning of AAA patients. However, manual segmentation of CTA images is labor intensive and time consuming. Hence, there is a growing need for automated segmentation algorithms, particularly when these influence treatment planning. The deep-learning pipeline proposed in this work is designed to automatically segment AAA CTA images. The framework adapted a fully developed patch-based dilated modified U-Net model, which shows remarkable efficiency in accurately delineating AAA regions within the CTA scans. During the prediction phase, the deep learning architecture demonstrates exceptional speed, requiring $17~\pm ~0.02$ milliseconds per frame to generate the final segmented output. Building upon this work, we included the application of Non-Uniform Rational B-Splines (NURBS) to enhance the segmentation process. This advancement is essential in addressing the critical need for clinical accuracy in medical image segmentation. NURBS enables the creation of continuous curves that seamlessly conform to the intricate contours of anatomical structures, offering a significant improvement in segmentation accuracy. Through the integration of advanced deep learning architectures and the precision of NURBS for segmentation refinement, coupled with the fast processing time and accurate segmentation, the the proposed model represents a promising clinical tool that can be used in the clinical management of AAAs.

1 January 2025 in IEEE Access
Verified
Journal Article
Open access
MRMerjulah Roby
Merjulah Roby
Abu Noman Md SakibAbu Noman Md Sakib
Abu Noman Md Sakib
ZZZijie Zhang
Zijie Zhang
SMSatish C. Muluk
Satish C. Muluk
MEMark K. Eskandari
Mark K. Eskandari
Ender A FinolEnder A Finol
Ender A Finol
This work presents an automated deep learning (DL) based framework for segmenting abdominal aortic aneurysm (AAA) in contrast-enhanced computed tomography angiography (CTA) images, which was developed to support AAA screening and analysis. The framework includes a dynamic router that assigns image regions to three specialized U-Net models, each trained to handle different aspects of the segmentation. It was trained and validated on 9,080 images and tested on 1,560 images representative of 22 unique patients. The model accurately segmented both the aortic lumen and the outer wall, achieving dice scores (DS) of 0.9648 and 0.9615, intersection over union (IoU) scores of 0.9324 and 0.9264, and Hausdorff distance (HD95) percentile values of 1.3490 mm and 1.3670 mm, respectively. The fully automated system processes each image frame in approximately 17 ± 1 milliseconds, making it suitable for real-time use. In certain complex cases where improved clinical accuracy is required, non-uniform rational B splines (NURBS) were used to manually refine the segmentation. In these cases, the NURBS correction time ranges from 3 to 20 seconds per frame. The framework’s training and validation demonstrate its potential as a reliable tool for AAA detection and clinical decision-making. Future work should focus on integrating multimodal imaging and optimization of NURBS to further improve its accuracy and efficiency.

23 January 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
TCTejas Canchi
Tejas Canchi
Sourav PatnaikSourav Patnaik
Sourav Patnaik
HNHong N. Nguyen
Hong N. Nguyen
Eddie YK NgEddie YK Ng
Eddie YK Ng
SNSriram Narayanan
Sriram Narayanan
Ender A FinolEnder A Finol
Ender A Finol
In the present work we provide a quantitative assessment of the biomechanical and geometric features that characterize abdominal aortic aneurysm (AAA) models generated from 19 Asian and 19 Caucasian diameter-matched AAA patients. 3D models were used to compute peak wall stress, 99th percentile wall stress (99thWS), and spatially averaged wall stress for each AAA. In addition, 51 global geometric indices were calculated, which quantify the wall thickness, shape, and curvature of each AAA. The indices were correlated to 99thWS (the only biomechanical metric that exhibited significant association with geometric indices) using Spearman's correlation and subsequently with multivariate linear regression using backward elimination. For the Asian AAA group, 99thWS was highly correlated (R2 = 0.77) with tortuosity, intraluminal thrombus volume, and area averaged Gaussian curvature. Similarly, 99thWS in the Caucasian AAA group was highly correlated (R2 = 0.87) with maximum AAA diameter, distal neck diameter, diameter-height ratio, minimum wall thickness variance, mode of the wall thickness variance, and area averaged Gaussian curvature. Significant differences were found between the groups for ten geometric indices; however, no differences were found for any of their respective biomechanical attributes. Assuming maximum AAA diameter as the most predictive metric for wall stress was found to be imprecise: 24% and 28% accuracy for the Asian and Caucasian groups, respectively. This investigation reveals that geometric indices other than maximum AAA diameter can serve as predictors of wall stress, and potentially for assessment of aneurysm rupture risk, in the Asian and Caucasian AAA populations.

7 February 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
MRMerjulah Roby
Merjulah Roby
Juan C. RestrepoJuan C. Restrepo
Juan C. Restrepo
DSDeepak K. Shan
Deepak K. Shan
SMSatish C. Muluk
Satish C. Muluk
MEMark K. Eskandari
Mark K. Eskandari
Ender A FinolEnder A Finol
Ender A Finol
Abdominal Aortic Aneurysm (AAA) remains a significant public health challenge, with an 82.1% increase in related fatalities from 1990 to 2019. In the United States alone, AAA complications resulted in an estimated 13,640 deaths between 2018 and 2021. In clinical practice, computed tomography angiography (CTA) is the primary imaging modality for monitoring and pre-surgical planning of AAA patients. CTA provides high-resolution vascular imaging, enabling detailed assessments of aneurysm morphology and informing critical clinical decisions. However, manual segmentation of CTA images is labor-intensive and time consuming, underscoring the need for automated segmentation algorithms, particularly when feature extraction from clinical images can inform treatment decisions. We propose a framework to automatically segment the outer wall of the abdominal aorta from CTA images and estimate AAA wall stress. Our approach employs a patch-based dilated modified U-Net model to accurately delineate the outer wall boundary of AAAs and Nonlinear Elastic Membrane Analysis (NEMA) to estimate their wall stress. We further integrate Non-Uniform Rational B-Splines (NURBS) to refine the segmentation. During prediction, our deep learning architecture requires 17±0.02 milliseconds per frame to generate the final segmented output. The latter is used to provide critical insight into the biomechanical state of stress of an AAA. This modeling strategy merges advanced deep learning architecture, the precision of NURBS, and the advantages of NEMA to deliver a robust and efficient method for computational analysis of AAAs.

6 May 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
Juan C. RestrepoJuan C. Restrepo
Juan C. Restrepo
MBMaria L. Bolanos
Maria L. Bolanos
SBSeungik Baek
Seungik Baek
SMSatish C. Muluk
Satish C. Muluk
MEMark K. Eskandari
Mark K. Eskandari
Ender A FinolEnder A Finol
Ender A Finol
Background/Objectives: Abdominal aortic aneurysm (AAA) surveillance is based largely on monitoring the maximum diameter, a single scalar metric that obscures regional remodeling and offers limited information on the location and time dependency of the growth rate. The present work addresses this limitation with a geometry-based patient-specific framework that learns local, linear evolution from longitudinal clinical imaging, yielding 3D forecasts of AAA geometry at arbitrary future times. Methods: Lumen and outer wall surfaces are represented on a centerline-anchored cylindrical grid, with subsequent implementation of individualized linear mixed-effects models. The model is explicitly interpretable as the fixed effects predict global trends and the random effects represent regional heterogeneity. In a multicenter cohort of 79 patients, we evaluated forecasts using spatial similarity (with the 95th percentile of the Hausdorff distance—HD95) and clinically relevant global geometric scalars such as maximum diameter and volume. Results: When forecasting a future AAA geometry, the model achieved sub-millimetric HD95 spatial errors and less than 6% error for the aforementioned global scalars. The model was deployed in an interactive application named the Aneurysm Forecasting Studio, which allows a user to visualize the AAA in an explorable forecast space. Conclusions: During typical clinical surveillance intervals, AAA geometric remodeling is reasonably approximated as locally linear in time, enabling transparent, fast forecasts that support surveillance optimization, threshold timing, and digital twin-based interventional planning.