Inderpreet Kaur

Inderpreet Kaur

Auto-generated profile, based on publicly available information

Inderpreet Kaur

Civil Engineering Department, Guru Nanak Dev Engineering College, Ludhiana, Punjab, India

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in Waste Management
Verified
Journal Article
Closed access
RSRafat Siddique
Rafat Siddique
Jamal M. KhatibJamal M. Khatib
Jamal M. Khatib
IKInderpreet Kaur
Inderpreet Kaur

12 August 2020 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
IDInderpreet Kaur Dhindsa
Inderpreet Kaur Dhindsa
HRHardeep Singh Rai
Hardeep Singh Rai
HSHarvinder Singh
Harvinder Singh
Reinforced concrete plates stiffened by the beams in the orthogonal directions are widely used in bridges and buildings. Local failure occurs due to stiff beams whereas shallow beams cause global collapse failure in the plate. A theoretical model using inelastic analysis (yield line analysis) has been formulated to predict the behaviour of the rectangular hybrid-reinforced concrete-stiffened-plate system which recognized the benefits of different types of fibre-reinforced polymer fabric and ferrocement in tension side. Parametric study was also conducted to capture the influence of different parameters such as number of panels, plate aspect ratio and beam strength parameter on the flexural capacity of plate system. Designer can select the proportionate hybrid-stiffened-plate system which fails globally to avoid negative yield lines through design chart. In the experimental study, four rectangular hybrid-stiffened-plate structural systems were developed with two internal beams in each perpendicular direction incorporating ferrocement and unidirectional carbon fibre–reinforced polymer fabric, unidirectional basalt fibre–reinforced polymer fabric and bidirectional glass fibre–reinforced polymer fabric sheet on the bottom side. The experimental ultimate load was recorded maximum in unidirectional carbon hybrid–stiffened-plate system, however, unidirectional basalt hybrid–stiffened-plate system gave the best performance with respect to the cost analysis. The numerical analysis had a reasonable consistency with experimental and analytical results.

21 December 2018 in Materials Today: Proceedings
Verified
Journal Article
Closed access
IKInderpreet Kaur
Inderpreet Kaur
HRHardeep Singh Rai
Hardeep Singh Rai
HSHarvinder Singh
Harvinder Singh