In recent years, flexible strain sensors have attracted increasing interest, and accurate sensing and comfortable wearables are highly demanded. However, current flexible strain sensors fail to have wide linearity and high sensitivity simultaneously, and their adhesion is insufficient for convenient wear and precise motion monitoring. Herein, chitosan/poly(vinyl alcohol) hydrogels with phytic acid (PA) and boric acid (BA) as crosslinkers (CS/PVA–PA–BA hydrogels) were fabricated. The synergy of phytic acid and boric acid not only improved the mechanical properties of the obtained hydrogels (1070% of fracture strain and 0.83 MPa of fracture stress), but also provided them with outstandingly strong adhesion. Their adhesive strength was up to 527 kPa for a variety of materials, including glass, silica rubber, steel, polytetrafluoroethylene (PTFE), and skin. In addition, the hydrogel-based strain sensor demonstrated high sensitivity (gauge factor = 4.61), a wide linear strain range (up to 1000%, R2 = 0.996), fast response time (90 ms), and good stability. A flexible strain sensor with such high sensitivity and wide linear range simultaneously, to the best of our knowledge, has never been reported before. The development of CS/PVA–PA–BA hydrogels is expected to inspire a novel method for high-adhesive and high-sensing-performance wearable electronics.
Flexible strain sensors have attracted great interest in many fields, including wearable devices, healthcare monitoring, and electronic skin. However, their non-linearity and tardy response time severely influence their sensing precision, and their low toughness, inferior environmental adaptation and non-recyclability are bad for their durability and unfavorable for electronic waste management. Here, we designed and synthesized a wide linear range and fast response strain sensor based on ionic conductive hydrogels (PVA–CS–PA hydrogels) using biodegradable polyvinyl alcohol (PVA) and chitosan (CS) as the polymer backbone, and biogenic phytic acid (PA) as the crosslinker. PVA–CS–PA hydrogels are tough and ductile. The hydrogel with a volume ratio of 3 : 2 for PA : H2O (PVA–CS–3PA–2 hydrogel), had a stretchability of 915 ± 32.44%, strength of 6.02 ± 0.18 MPa, and fracture energy of 5.28 ± 0.24 kJ m−2. It was also thermoplastic and anti-drying (more than 90% water retention after 30 days). The hydrogel-based strain sensor displayed a wide linear working range up to 900% strain, a fast response time within 50 ms, and reliable stability to detect subtle and large motions. Moreover, its sensing performance is maintained well after a thermoplastic process and long-term storage, suggesting it has reusability and a long lifetime. This tough, wide linear range, fast response, green, and recyclable hydrogel-based strain sensor is expected to pave the way for the development of environmentally friendly and high-performance artificial intelligence in versatile electronic applications.
28 June 2019 in ACS Applied Materials & Interfaces