Melvin Geubbelmans

Melvin Geubbelmans

Auto-generated profile, based on publicly available information

Melvin Geubbelmans

Data Science Institute, Hasselt University, Hasselt, Belgium

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
TBTomasz Burzykowski
Tomasz Burzykowski
MGMelvin Geubbelmans
Melvin Geubbelmans
ARAxel-Jan Rousseau
Axel-Jan Rousseau
Dirk ValkenborgDirk Valkenborg
Dirk Valkenborg

25 September 2023 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
TBTomasz Burzykowski
Tomasz Burzykowski
MGMelvin Geubbelmans
Melvin Geubbelmans
ARAxel-Jan Rousseau
Axel-Jan Rousseau
DVDirk Valkenborg
Dirk Valkenborg

9 September 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MGMelvin Geubbelmans
Melvin Geubbelmans
JCJari Claes
Jari Claes
KNKim NIJSTEN
Kim NIJSTEN
PGPascal Gervois
Pascal Gervois
SASimon Appeltans
Simon Appeltans
CFChristel Faes
Christel Faes
Digital pathology has become increasingly popular for research and clinical applications. Using high-quality microscopes to produce Whole Slide Images of tumor tissue enables the discovery of insights into biological aspects invisible to the human eye. These are acquired through downstream analyses using spatial statistics and artificial intelligence. Determination of the quality and consistency of these images is needed to ensure accurate outcomes when identifying clinical and subclinical image features. Additionally, the time-intensive process of generating high-volume images results in a trade-off that needs to be carefully balanced. This study aims to determine optimal instrument settings to generate representative images of pathological tissue using digital microscopy. Using various settings, an H&E stained sample was scanned using the ZEISS Axio Scan.Z1. Next, nucleus segmentation was performed on resulting images using StarDist. Subsequently, detections were compared between scans using a matching algorithm. Finally, nucleus-level information was compared between scans. Results indicated that while general matching percentages were high, similarity between information from replicates was relatively low. Additionally, settings resulting in longer scanning times and increased data volume did not increase similarity between replicates. In conclusion, the scan setting ultimately deemed optimal combined consistent and qualitative performance with low throughput time.