1 January 2002 in Diseases of Aquatic Organisms
Monoclonal antibodies specific to 22, 67 and 135 kDa proteins of yellow-head virus (YHV) were produced from a mouse immunized with partially purified YHV isolated from the haemolymph of experimentally YHV-infected Penaeus monodon. Four groups of monoclonal antibodies were identified. One group of antibodies bound only to native protein of YHV while the others were specific to 135, 67 and 22 kDa proteins in both native and denatured forms. All antibodies could be used to detect YHV infection by means of dot blot and immunohistochemistry. However, antibodies specific to the 22 kDa protein gave the best immunohistochemistry results in terms of intensity and sharpness of staining.
4 January 2002 in Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology
CKChatchadaporn Krungkasem
+1
1 January 2000 in Diseases of Aquatic Organisms
A monoclonal antibody specific to yellow head virus (YHV) was produced from a mouse immunized with gill extracts prepared from laboratory-reared Penaeus monodon dually infected with YHV and white spot syndrome virus (WSSV). One clone designated V3-2B specifically bound to native and SDS-treated viral specific antigens. Immunocytochemical studies of infected gills revealed viral specific immunoreactivities in the cytoplasm of gill tissue and in haemocytes. No antibody binding was observed in gills from non-infected shrimp. In addition, immunocytochemical examination of tissues from shrimp experimentally infected with YHV gave a positive reaction, while tissues from uninfected control shrimp or shrimp experimentally infected with WSSV did not. Western blot analysis indicated that the antibody reacted with a protein of approximately 135 kD that was present only in shrimp infected with YHV. In dot-blot indirect immunoperoxidase assays, the antibody was able to detect viral associated antigen in diluted haemolymph up to 1:50 dilution and in an ammonium sulfate precipitate of haemolymph up to 1:1000 dilution. The results suggested that this antibody might be useful for development of effective diagnostic techniques for both heavy and mild YHV infections in shrimp.
20 August 2013 in Aquaculture Research
Vibrio harveyi is a causative agent of the Vibriosis or luminescent bacterial disease in worldwide aquaculture industry. A reliable assay for identification of V. harveyi infection is important to prevent the bacterial spread. In this study, biotinylated loop-mediated isothermal amplification (LAMP) amplicons were produced by a set of four designed primers that recognized specifically the V. harveyi vhhP2 gene, encoding a putative outer membrane protein with unknown function, followed by hybridization with an fluorescein isothiocyanate (FITC)-labelled probe and lateral flow dipstick (LFD) detection. A novel set of PCR primer was also designed specifically to vhhP2 gene and appear to be a species-specific tool for V. harveyi detection. The optimized time and temperature conditions for the LAMP assay were 90 min at 65°C. The LAMP-LFD and PCR methods accurately identified 22 isolates of V. harveyi but did not detect 16 non-harveyi Vibrio isolates, and 34 non-Vibrio bacterial isolates. The sensitivity of LAMP-LFD for V. harveyi detection in pure culture was 1.1 × 102 CFU mL−1 or equivalent to 0.6 CFU per reaction, while that of PCR was 6 CFU per reaction. For spiked shrimp sample, the sensitivity of LAMP was 1.8 × 103 CFU g−1 or equivalent to 5 CFU per reaction, while that of PCR was 50 CFU per reaction. In conclusion, the established LAMP-LFD methods provided a valuable tool for rapid identification of V. harveyi and can be used to distinguish V. harveyi from V. campbellii.
1 February 2001 in Peptides
7 September 1999 in Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology