Chris Williams

Chris Williams

Auto-generated profile, based on publicly available information

Chris Williams

Queen's University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2017 in Nano Letters
Verified
Journal Article
Closed access
LWLuda Wang
Luda Wang
CWChristopher M. Williams
Christopher M. Williams
MBMichael S. H. Boutilier
Michael S. H. Boutilier
PKPiran R. Kidambi
Piran R. Kidambi
RKRohit Karnik
Rohit Karnik

1 October 2018 in APL Materials
Verified
Journal Article
Open access
PDF file
JAJack Alvarenga
Jack Alvarenga
YAYuki Ainge
Yuki Ainge
CWChris Williams
Chris Williams
AMAubrey Maltz
Aubrey Maltz
TBThomas Blough
Thomas Blough
JAJoanna Aizenberg
Joanna Aizenberg
Membrane filtration technology is widely used across several industries. But its efficiency is plagued by fouling, which ultimately deteriorates the membrane’s performance. This paper provides a research update on the biologically inspired liquid-enabled gating mechanism that acts as a novel filtration and separation approach offering reduction in transmembrane pressure (TMP), improved throughput, and reduced fouling. We study the performance of such Liquid Gated Membranes (LGMs) and present their benefits for filtration in the presence of model inorganic (nanoclay particles) fouling. We show over twofold higher throughput, nearly threefold longer time to foul, more than 60% reduction in irreversible fouling, ability to return to baseline pressures after backwashing along with reduction in use of backwash water, and 10%-15% reduction in TMP for filtration of nanoclay particles. Fouling models exhibit not only delayed onset of fouling for LGMs compared to the control but also different fouling characteristics. These results demonstrate the potential of the liquid gating mechanism, which can lead to breakthroughs in membrane technology applications in particle filtration, microfiltration, and ultrafiltration.

30 May 2021 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
AZAnan Zhang
Anan Zhang
ATAlexandre Tessier
Alexandre Tessier
CWChris Martin Williams
Chris Martin Williams
SAShideh Kabiri Ameri
Shideh Kabiri Ameri
The recent COVID-19 pandemic has proven that low-cost wireless wearable medical device which offer reliable continuous health monitoring can be extremely valuable and game changing tools in early diagnosis, control and management of contiguous disease. Current commercial wearables are not reliable and accurate enough for medical diagnosis, further they are rigid, bulky, and expensive. Here we present a skin-mounted, low-cost, soft and stretchable wearable electrocardiography (ECG) sensor-system which enables continuous and wireless ECG recording. The ECG sensor-system consists of low-cost, disposable, soft and stretchable, carbon-based electrodes patch; and a reusable, front-end and wireless circuits patch. The sensor patches are made by our developed low-cost scalable manufacturing method of spray-printing, on breathable, conformal, stretchable medical adhesives. The softness and thinness of electrodes patch ensure the conformability of electrodes to skin, maximizes the quality of sensing by decreasing the electrode-skin impedance and consequently improving the signal to noise ratio (SNR) and furthermore offer comfort to users. The reusable ECG circuit patch consists of three-dimensional stretchable/deformable interconnects (SDI) integrated with off-the-shelf integrated circuit components. SDI is made of microfluidic channels filled with liquid metal (LM). Unless other reported liquid metal based interconnects, SDI has been designed in 3D form to increase the stretchability and make it robust to deformations in all three x, y and z axis. The sensor-system is also waterproof and the developed disposable sensors are breathable and more comfortable than commercial wet gel electrodes. The recorded ECG signal can be sent to a personal device such as tablet and laptop wirelessly and be displayed in real-time. The developed sensor-system is a platform that can be applied for the construction of various types of sensor-systems with other sensing capabilities. Figure 1

9 October 2022 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
CWChris Williams
Chris Williams
SAShideh Kabiri Ameri
Shideh Kabiri Ameri
As performant and well-established as conventional silicon-based electronics have become, the era of wearable electronics and the Internet-of-Things has created a demand for robust electronic devices that can conform to the surfaces of the human body. Whereas the mechanical mismatch between rigid silicon electronics and the human body represents a fundamental limit to conventional non-invasive health sensing, wearable electronics and electrodes that can conform to the microscopic features of the skin1,2 can circumvent most of the motion artifacts inherent to conventional, rigid sensing devices, and facilitate continuous health monitoring as is required for modern, more proactive healthcare. Unfortunately, without addressing this fundamental mechanical incompatibility, devices that leverage the high density of transistors available in rigid silicon-based integrated circuits are handicapped by how well they can maintain contact with the body, and consequently are prone to failure at the sensor-circuit interface. The extraordinary properties of two-dimensional materials pose a unique opportunity for addressing this mechanical mismatch. Their unusual mechanical strength combined with their ultimate thinness, optical transparency, and favorable electronic transport properties3 makes them ideal candidates for the next generation of highly conformable wearable electronics free of the constraints of a rigid silicon circuit board—however, minimizing local strain in the vicinity of the active devices to ensure reliable operation remains a priority. Using a design informed by finite element method (FEM) simulations, our proposed strain-neutralizing 2D transistors are configured to resist applied strains on the order of the 30% strains human skin can withstand by redistributing strain away from active regions. Tight binding simulations of the transistor channels helps with further compensation of residual strain in the active regions, alongside careful consideration of materials and device architecture during fabrication. Together, these considerations help realize the possibility of fully integrated strain-neutralized 2D transistors compatible with state-of-the-art conformable wearable sensors. [1]S. Kabiri Ameri et al., “Graphene electronic tattoo sensors,” ACS Nano, 11, 7634–7641, 2017. [2] S. Kabiri Ameri et al., “Imperceptible electrooculography graphene sensor system for human–robot interface”, npj 2D Materials and Applications, 2, 1-7, 2018. [3] A. H. Castro Neto, F. Guinea, N. M. R. Peres, K. S. Novoselov, and A. K. Geim, “The electronic properties of graphene,” Rev. Mod. Phys., vol. 81, no. 1, pp. 109–162, Jan. 2009, doi: 10.1103/RevModPhys.81.109.

30 May 2021 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
CWChris Martin Williams
Chris Martin Williams
SAShideh Kabiri Ameri
Shideh Kabiri Ameri
The ability to fabricate incredibly sophisticated integrated circuits at low cost rendered modern electronics more affordable, efficient, and functional. This monumental advance in technology would usher in the age of the Internet-of-things and transform wearable electronics from a largely academic pursuit into an everyday reality around which a robust and rapidly growing industry has formed. However, even the highly connected wearable electronics of today leave much to be desired with respect to their compatibility with soft tissues such as skin. More specifically, the poor compliance of the rigid, silicon-based integrated circuits conventionally used in the construction of these devices with the soft, curvilinear surfaces of the human body can result in high impedances at the skin-sensor interface which in turn contribute to low signal-to-noise ratios as well as poor sensitivity and accuracy. Motion artifacts originating from the poor conformability of such devices only exacerbate these problems. This mechanical mismatch represents a significant hurdle in the effort to move away from the conventional reactive approach to healthcare towards a more proactive approach that leverages ‘truly’ wearable sensors to improve health outcomes. Transistors are the building blocks upon which the vast majority of modern electronics are built. Although single transistors can be used to amplify or otherwise control electronic signals using only a small input signal, most of their functionality comes in the form of integrated circuits (ICs) consisting of many connected transistors. Conventional techniques for fabricating ICs exploit the rigidity of the semiconducting silicon substrate to ensure the device performance is consistent throughout the circuit. In contrast, integrated circuits for highly compliant wearable electronics that can conform even to microscopic features of the skin[1,2] face the inherent challenge of maintaining their electrical performance under mechanical deformations. As is the case with most sensors, the front-end circuitry for these devices (responsible for conveying the information contained in the signal – either wirelessly or without wires – to the end user) requires reliable and performant integrated circuits. Of course, integrating soft, ultra-thin sensors with the rigid silicon-based integrated circuits results in a mechanical mismatch with mechanical failure at the interface where the two components meet being the most likely scenario. Instead, here we present an approach which uses two-dimensional (2D) transistors in a specially designed strain-neutralizing configuration which circumvents much of the difficulties associated with the aforementioned mismatch. The extraordinary properties of 2D materials—particularly their excellent mechanical flexibility, ultimate thinness, optical transparency, and favorable transport properties for realizing electronics—make them prime candidates for replacing conventional silicon-based transistor circuits in next-generation wearable applications. Using finite-element analysis we have designed and simulated a compliant, strain-insensitive substrate which can resist uniaxial applied strains upwards of 35%. Moreover, simulations of the electronic band structure of the transistors under applied strain is used to optimize the circuit design and further minimize the effect of strain in the transistors. These electronic and mechanical simulations are used together in the configuration and subsequent fabrication of fully integrated strain-neutralized 2D transistors compatible with state-of-the-art soft stretchable wearable sensors. [1]S. Kabiri Ameri et al., “Graphene electronic tattoo sensors,” ACS Nano, 11, 7634–7641, 2017. [2] S. Kabiri Ameri et al., “Imperceptible electrooculography graphene sensor system for human–robot interface”, npj 2D Materials and Applications, 2, 1-7, 2018.

9 October 2022 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
AZAnan Zhang
Anan Zhang
ATAlexandra Tessier
Alexandra Tessier
CWChris Williams
Chris Williams
SAShideh Kabiri Ameri
Shideh Kabiri Ameri
Electrocardiography (ECG) is a primary tool for diagnosis of various types of disease and disorders such as arrhythmias, coronary heart disease, heart attack, mental disorders, etc. Reliable wearable ECG devices can be a valuable tool in early diagnosis and effective treatment of such disease and disorders. Convention wearable ECG sensor-systems are rigid, bulky, expensive, and the recorded ECG signals using these wearable devices lack required accuracy for medical diagnosis mainly due to motion artifacts that is originated from slippage of sensors on skin and/or instable interface between the soft sensor and the rigid electronic circuits. Here, we report a low-modulus, soft and stretchable wearable electrocardiography (ECG) sensor-system patch which enables continuous and long-term recording of ECG signals with minimal motion artifacts. This system consists of two reusable, detachable-attachable patches: sensor patch and circuit patch, as shown in Figure 1a. The reusable multi-wall carbon nanotube (MWCNT) based sensor patch is fabricated on stretchable elastomer substrate by our developed cost and time-effective method. Reusable, front-end and wireless circuit patch is made by integration of the off-the-shelf integrated circuit components with three-dimensional (3D) stretchable-deformable interconnects (SDI). SDIs are 3D springs of liquid metal (EGaIn). Unlike other reported liquid metal based interconnects, SDI has been designed in 3D form to increase the stretchability and make it low-modulus and robust to deformations in all directions. The stretchability of SDI structure is beyond 500% (the limit of our measurement system) without any negligible change in electrical resistivity of the interconnects. With less than 1% change in the resistance of SDIs after 50,000 cycles of applied tensile strain of 200%, the SDI structure ensures reliable stretchability and durability of the circuit patch for long-term electrocardiography. The sensor patch is soft, stretchable and it is fabricated using a low-cost scalable method. This soft and stretchable ECG sensor-system shows comparable performance with respect to medical grade Ag/AgCl wet gel electrodes. Our CNT-PDMS sensors shows low electrode-skin interface impedance and low susceptibility to motion artifact which similar of it in medical grade Ag/AgCl wet gel sensors (Fig. 1b). Further, it is waterproof, reusable and comfortable to wear. The circuit patch includes a rechargeable battery and ECG signals is wirelessly sent to a personal device such as cellphone, tablet and laptop through Bluetooth low energy (BLE) and it is displayed in real-time (Fig. 1c) Our developed sensor-system is a multi-use platform which can be applied for the detection of EMG, EEG or EOG signals. Figure 1