Laurent Fiorina

Laurent Fiorina

Auto-generated profile, based on publicly available information

Laurent Fiorina

Institut Cardiovasculaire Paris Sud (ICPS), Hôpital privé Jacques Cartier, Ramsay Santé, Massy, France

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2025 in European Heart Journal
Verified
Journal Article
Open access
LFLaurent Fiorina
Laurent Fiorina
TCTanner Carbonati
Tanner Carbonati
KNKumar Narayanan
Kumar Narayanan
JLJia Li
Jia Li
CHChristine Henry
Christine Henry
EMEloi Marijon
Eloi Marijon
Background and Aims: Accurate near-term prediction of life-threatening ventricular arrhythmias would enable pre-emptive actions to prevent sudden cardiac arrest/death. A deep learning–enabled single-lead ambulatory electrocardiogram (ECG) may identify an ECG profile of individuals at imminent risk of sustained ventricular tachycardia (VT). Methods: This retrospective study included 247 254, 14 day ambulatory ECG recordings from six countries. The first 24 h were used to identify patients likely to experience sustained VT occurrence (primary outcome) in the subsequent 13 days using a deep learning–based model. The development set consisted of 183 177 recordings. Performance was evaluated using internal (n = 43 580) and external (n = 20 497) validation data sets. Saliency mapping visualized features influencing the model’s risk predictions. Results: Among all recordings, 1104 (.5%) had sustained ventricular arrhythmias. In both the internal and external validation sets, the model achieved an area under the receiver operating characteristic curve of .957 [95% confidence interval (CI) .943–.971] and .948 (95% CI .926–.967). For a specificity fixed at 97.0%, the sensitivity reached 70.6% and 66.1% in the internal and external validation sets, respectively. The model accurately predicted future VT occurrence of recordings with rapid sustained VT (≥180 b.p.m.) in 80.7% and 81.1%, respectively, and 90.0% of VT that degenerated into ventricular fibrillation. Saliency maps suggested the role of premature ventricular complex burden and early depolarization time as predictors for VT. Conclusions: A novel deep learning model utilizing dynamic single-lead ambulatory ECGs accurately identifies patients at near-term risk of ventricular arrhythmias. It also uncovers an early depolarization pattern as a potential determinant of ventricular arrhythmias events.

6 July 2024 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
PDF file
LFLaurent Fiorina
Laurent Fiorina
PCPascale Chemaly
Pascale Chemaly
JCJoffrey Cellier
Joffrey Cellier
MSMina Ait Said
Mina Ait Said
CCCharlène Coquard
Charlène Coquard
BLBaptiste Lefebvre
Baptiste Lefebvre
Aims: Smartwatch electrocardiograms (SW ECGs) have been identified as a non-invasive solution to assess abnormal heart rhythm, especially atrial arrhythmias (AAs) that are related to stroke risk. However, the performance of these tools is limited and could be improved with the use of deep neural network (DNN) algorithms, particularly for specific populations encountered in clinical cardiology practice. Methods and results: A total of 400 patients from the electrophysiology department of one tertiary care hospital were included in two similar clinical trials (respectively, 200 patients per study). Simultaneous ECGs were recorded with the watch and a 12-lead recording system during consultation or before and after an electrophysiology procedure if any. The SW ECGs were processed by using the DNN and with the Apple watch ECG software (Apple app). Corresponding 12-lead ECGs (12L ECGs) were adjudicated by an expert electrophysiologist. The performance of the DNN was assessed vs. the expert interpretation of the 12L ECG, and inconclusive rates were reported. Overall, the DNN and the Apple app presented, respectively, a sensitivity of 91% [95% confidence interval (CI) 85–95%] and 61% (95% CI 44–75%) with a specificity of 95% (95% CI 91–97%) and 97% (95% CI 93–99%) when compared with the physician 12L ECG interpretation. The DNN was able to provide a diagnosis on 99% of ECGs, while the Apple app was able to classify only 78% of strips (22% of inconclusive diagnosis). Conclusion: In this study, by including patients from a cardiology department, a DNN-based algorithm applied to an SW ECG provided an accurate diagnosis for AA detection on virtually all tracings, outperforming the SW algorithm.

8 September 2022 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
LFLaurent Fiorina
Laurent Fiorina
CMCarole Maupain
Carole Maupain
CGChristophe Gardella
Christophe Gardella
VMVladimir Manenti
Vladimir Manenti
FSFiorella Salerno
Fiorella Salerno
EMEloi Marijon
Eloi Marijon
Background: Holter analysis requires significant clinical resources to achieve a high‐quality diagnosis. This study sought to assess whether an artificial intelligence (AI)‐based Holter analysis platform using deep neural networks is noninferior to a conventional one used in clinical routine in detecting a major rhythm abnormality. Methods and Results: A total of 1000 Holter (24‐hour) recordings were collected from 3 tertiary hospitals. Recordings were independently analyzed by cardiologists for the AI‐based platform and by electrophysiologists as part of clinical practice for the conventional platform. For each Holter, diagnostic performance was evaluated and compared through the analysis of the presence or absence of 5 predefined cardiac abnormalities: pauses, ventricular tachycardia, atrial fibrillation/flutter/tachycardia, high‐grade atrioventricular block, and high burden of premature ventricular complex (>10%). Analysis duration was monitored. The deep neural network–based platform was noninferior to the conventional one in its ability to detect a major rhythm abnormality. There were no statistically significant differences between AI‐based and classical platforms regarding the sensitivity and specificity to detect the predefined abnormalities except for atrial fibrillation and ventricular tachycardia (atrial fibrillation, 0.98 versus 0.91 and 0.98 versus 1.00; pause, 0.95 versus 1.00 and 1.00 versus 1. 00; premature ventricular contractions, 0.96 versus 0.87 and 1.00 versus 1.00; ventricular tachycardia, 0.97 versus 0.68 and 0.99 versus 1.00; atrioventricular block, 0.93 versus 0.57 and 0.99 versus 1.00). The AI‐based analysis was >25% faster than the conventional one (4.4 versus 6.0 minutes; P <0.001). Conclusions: These preliminary findings suggest that an AI‐based strategy for the analysis of Holter recordings is faster and at least as accurate as a conventional analysis by electrophysiologists.

1 November 2016 in Annales de Cardiologie et d'Angéiologie
Verified
Journal Article
Closed access
MCMoini Cyrus
Moini Cyrus
BSB. Sidia
B. Sidia
DPD. Poindron
D. Poindron
LFL. Fiorina
L. Fiorina
AFA. Farge
A. Farge
MIM. El Issa
M. El Issa

1 January 2018 in Archives of Cardiovascular Diseases Supplements
Verified
Journal Article
Closed access
FBF. Bouvier
F. Bouvier
CMC. Maupain
C. Maupain
NRN.C. Roche
N.C. Roche
LFL. Fiorina
L. Fiorina
DPD. Poindron
D. Poindron
EGE. Gandjbakhch
E. Gandjbakhch

26 August 2025 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
LFLaurent Fiorina
Laurent Fiorina
TCTanner Carbonati
Tanner Carbonati
BMBaptiste Maille
Baptiste Maille
KNKumar Narayanan
Kumar Narayanan
PPPauline Porquet
Pauline Porquet
JDJean Claude Deharo
Jean Claude Deharo
BACKGROUND: Bradyarrhythmia is a common and potentially serious cause of syncope, often difficult to detect due to its intermittent nature. Traditional ECG monitoring methods either provide low diagnostic accuracy or delay diagnosis, increasing the risk of recurrence. We hypothesized that a deep learning–enabled, 24-hour, single-lead ECG could detect past episodes of bradyarrhythmia. METHODS: Using unselected 14-day single-lead ambulatory ECG recordings, we developed a deep learning model to identify patients with prior asystole from sinus arrest or complete heart block. The model was trained using the last 24 hours of each recording, free of bradyarrhythmias, to identify daytime sinus pause of ≥3 s, anytime sinus pause of ≥6 s, complete heart block, or a composite of these bradyarrhythmias from the previous 13 days. RESULTS: A total of 320 959 unselected 14-day ambulatory ECG recordings (mean age, 60.5±17.8 years; 60% female) were split into training (n=189 414), tuning (n=45 982), internal validation (n=43 390), and external validation (n=42 173) sets. External validation of prior daytime sinus pause ≥3 s, anytime sinus pause ≥6 s, complete heart block, and a composite end point demonstrated an area under the receiver operating characteristic curve of 0.89, 0.87, 0.93, and 0.89, respectively, with negative predictive values between 97.9 and 99.9%. In addition to this approach of uncovering past events, our model was also tested for its ability to predict bradyarrhythmias within the following 13 days using the first 24 hours of ECG data, achieving an AUC of 0.88 for the composite end point. CONCLUSIONS: A deep learning–enabled ambulatory ECG is capable of unmasking underlying conduction tissue system disease. This tool may help identify patients with significant intermittent bradyarrhythmia, potentially improving timely diagnosis and management.