4 December 2024 in Nature
New particle formation (NPF) in the tropical upper troposphere is a globally important source of atmospheric aerosols1–4. It is known to occur over the Amazon basin, but the nucleation mechanism and chemical precursors have yet to be identified2. Here we present comprehensive in situ aircraft measurements showing that extremely low-volatile oxidation products of isoprene, particularly certain organonitrates, drive NPF in the Amazonian upper troposphere. The organonitrates originate from OH-initiated oxidation of isoprene from forest emissions in the presence of nitrogen oxides from lightning. Nucleation bursts start about 2 h after sunrise in the outflow of nocturnal deep convection, producing high aerosol concentrations of more than 50,000 particles cm− 3. We report measurements of characteristic diurnal cycles of precursor gases and particles. Our observations show that the interplay between biogenic isoprene, deep tropical convection with associated lightning, oxidation photochemistry and the low ambient temperature uniquely promotes NPF. The particles grow over time, undergo long-range transport and descend through subsidence to the lower troposphere, in which they can serve as cloud condensation nuclei (CCN) that influence the Earth’s hydrological cycle, radiation budget and climate1,4–8.
4 December 2024 in Nature
Aircraft observations have revealed ubiquitous new particle formation in the tropical upper troposphere over the Amazon1,2 and the Atlantic and Pacific oceans3,4. Although the vapours involved remain unknown, recent satellite observations have revealed surprisingly high night-time isoprene mixing ratios of up to 1 part per billion by volume (ppbv) in the tropical upper troposphere5. Here, in experiments performed with the CERN CLOUD (Cosmics Leaving Outdoor Droplets) chamber, we report new particle formation initiated by the reaction of hydroxyl radicals with isoprene at upper-tropospheric temperatures of −30 °C and −50 °C. We find that isoprene-oxygenated organic molecules (IP-OOM) nucleate at concentrations found in the upper troposphere, without requiring any more vapours. Moreover, the nucleation rates are enhanced 100-fold by extremely low concentrations of sulfuric acid or iodine oxoacids above 105 cm−3, reaching rates around 30 cm−3 s−1 at acid concentrations of 106 cm−3. Our measurements show that nucleation involves sequential addition of IP-OOM, together with zero or one acid molecule in the embryonic molecular clusters. IP-OOM also drive rapid particle growth at 3–60 nm h−1. We find that rapid nucleation and growth rates persist in the presence of NOx at upper-tropospheric concentrations from lightning. Our laboratory measurements show that isoprene emitted by rainforests may drive rapid new particle formation in extensive regions of the tropical upper troposphere1,2, resulting in tens of thousands of particles per cubic centimetre.
1 May 2014 in Annals of Forest Science
7 November 2025 in Atmospheric Chemistry and Physics
We present measurements from the aircraft-based TPEx (Tropopause composition gradients and mixing Experiment) mission in June 2024 over Europe. The measurement platform, a Learjet 35A, was equipped with in-situ trace gas and aerosol measurements and filter samplers for offline analysis. For vertical gradient measurements of trace species and aerosol, we conducted redundant measurements on a fully automated towed sensor shuttle (TOSS) 200 m below the aircraft. On 17 June 2024, we observed a filament with elevated aerosol number concentrations of up to 800 particles cm−3 between 100 nm and 1 µm. This is higher by a factor of two to four than the local background. Carbon monoxide (CO) mixing ratios were larger than 100 ppbv. Single particle analysis of impactor samples using electron microscopy show characteristic biomass burning (BB) aerosol in the tropopause region. The TOSS measurements also allow the calculation of the potential temperature gradient ( ). Within the polluted filament, we observe changes towards smaller gradients, which is presumably due to an increase of potential temperature at lower altitudes by radiative heating as a consequence of the transported BB aerosol. Trajectory analysis show air mass origin over Canada with low-level long-range transport and subsequent uplift by a warm conveyor belt (WCB) over Europe as additional pathway of pollution into the UTLS. Furthermore, this analysis yields that BB aerosol can be transported in a WCB into the UTLS there it can be mixed with stratospheric air masses.
15 December 2022 in Aerosol Science and Technology
The SARS-CoV-2 pandemic forced many restrictions upon the public, such as the closing of schools, affecting social development and education of children. Here we tested air purifiers with HEPA filters as a measure to reduce the infection risk via airborne transmission during classes. We evaluated the efficiency and long-term performance of three devices over six month of operation at two schools by monitoring the particle decay from 0.003 µm to 10 µm. We found that the particle concentration was reduced reliably and spatially homogenously by 85 – 95% throughout the whole observed particle spectrum within ∼20 minutes for air exchange rates between 4.8 h−1 and 6.7 h−1. During the study we did not observe a clear decline in efficiency or performance of the air purifiers. We complemented our particle measurements with model calculations to estimate the virus concentration and inhaled dose of a susceptible person, assuming one infectious person was present. We calculated that the additional use of air purifiers reduced the number of potentially inhaled viruses at the end of the day by a factor of 2.65 relative to the case without air purifiers. Further, school-wide surveys indicated that the disturbance by the noise level of the air purifiers is to be considered and that the acceptance of air purifiers can be improved when the noise level is reduced. Overall, our study suggests that a combination of air purifiers and venting is a well-suited measure to reduce the potential indoor viral-load while still introducing fresh air into the room.
17 November 2025 in Atmospheric Measurement Techniques
In this paper we introduce the new TropoPause Composition TOwed Sensor Shuttle (TPC-TOSS), which constitutes an advanced development of the AIRcraft TOwed Sensor Shuttle (AIRTOSS), introduced by Frey et al. (2009). As part of a tandem measurement platform with a Learjet 35A, both platforms were equipped with redundant instruments for co-located measurements of aerosol size distribution (Ultra-High Sensitivity Aerosol Spectrometer, UHSAS), ozone (2BTech model 205), cloud particles (Back-Scatter Cloud Probe, BCP), as well as relative humidity, temperature and pressure. To measure the exact position of the two platforms as well as the relative distance of the TPC-TOSS to the Learjet a Global Positioning System (GPS) is installed on both platforms. Two identical Inertial Navigation Systems (INS) further allow to monitor attitude angles (roll, pitch, and heading) and accelerations. Laboratory tests before and ground tests as well as in-flight tests during the intensive operation period show a good agreement of the ozone and temperature measurements of better than 4.2 ppbv +1.1 % (ozone) and 0.5 °C (temperature) at a noise level of ± (2 ppbv + 0.5 %) for 2 s data (ozone) and ± 0.1 K for 1 Hz data (temperature). Stability of the ozone monitor mounted in the TPC-TOSS has been tested and is estimated to be 2.2 ppbv (offset, 1σ) and 0.7 % (gain, 1σ), respectively, based on the drift of offset and gain during regular calibrations between measurement flights in the two weeks operation period. The new TPC-TOSS was successfully flown during the TPEx I (TropoPause composition gradients and mixing Experiment) mission in June 2024 and performed four flights covering the altitude range between 6.4 and 10.9 km. The tropopause was crossed several times as evident from different temperature and ozone gradients as well as gradients of the aerosol number concentration. With the setup we are able to resolve transient stability and composition gradients ranging from almost zero or even negative to strong positive gradients of up to 25 K km−1 for potential temperature and from inverted to strong positive vertical gradients of ozone of up to 800 ppbv km−1, respectively. These gradients are caused by transport and mixing due to convection or shear induced turbulence at the tropopause.