Oskar Neumann

Oskar Neumann

Auto-generated profile, based on publicly available information

Oskar Neumann

Institute of Continuum Mechanics and Biomechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Egerlandstraße 5, Erlangen, 91058, Germany

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
ONOskar Neumann
Oskar Neumann
HSHarsh Vardhan Surana
Harsh Vardhan Surana
SMStephen Melly
Stephen Melly
PSPaul Steinmann
Paul Steinmann
SBSilvia Budday
Silvia Budday
The mechanical properties of brain and spinal cord tissue have proven to be extremely complex and difficult to assess. Due to the heterogeneous and ultra-soft nature of the tissue, the available literature shows a large variance in mechanical parameters derived from experiments. In this study, we performed a series of indentation experiments to systematically investigate the mechanical properties of porcine spinal cord tissue in terms of their sensitivity to indentation tip diameter, loading rate, holding time, ambient temperature along with cyclic and oscillatory dynamic loading. Our results show that spinal cord white matter tissue is more compliant than grey matter tissue with apparent moduli of 128.7 and 403.8 Pa, respectively. They show similar viscoelastic behavior with stress relaxation time constants of τ1=1.38s and τ2=36.29s for grey matter and τ1=1.46s and τ2=46.10s for white matter, while the initial peak force decreased by 54 % for grey and 59 % for white matter tissue. An increase of the applied loading rate by two orders of magnitude led to an approximate doubling of the apparent modulus for both tissue types. Thermal variations showed a decrease in apparent modulus of up to 30 % after heating from 20 to 37.0 °C. Our dynamic tests revealed a significant influence of cyclic preload on the stiffness, with a drop of up to 20 % and a relative decrease of up to 60 % after the first cycle compared to the total modulus drop after five cycles for spinal cord grey matter tissue. Oscillatory indentation experiments identified similar loss moduli for spinal cord grey and white matter tissue and a higher storage modulus for white matter tissue. This work provides systematic insights into the mechanical properties of spinal cord tissue under different loading scenarios using nanoindentation.

30 April 2026 in Acta Biomaterialia
Verified
Journal Article
Open access
ONOskar Neumann
Oskar Neumann
RRRahul Gopalan Ramachandran
Rahul Gopalan Ramachandran
HSHarsh Vardhan Surana
Harsh Vardhan Surana
Friedrich  PaulsenFriedrich Paulsen
Friedrich Paulsen
MSMichael Scholz
Michael Scholz
SBSilvia Budday
Silvia Budday
The ultrasoft nature and intricate geometry of the 'butterfly-shaped' spinal cord gray matter, surrounded by white matter, pose major challenges for experimental and computational characterization of tissue mechanics. With growing interest in modeling spinal cord injury, disease, and regeneration, reliable mechanical data are increasingly needed. To meet this demand, we developed a multimodal characterization pipeline, combining mesoscale spherical indentation of gray and white matter, macroscale rheometer-based compression-tension tests, nonlinear continuum mechanics modeling, and inverse finite element simulations, using Hertzian, neo-Hookean, and Ogden constitutive laws. Both testing modalities were applied sequentially on samples extracted along the cranio-caudal axis of porcine spinal cords to assess regional variations in mechanical properties. Compared with Hertzian and neo-Hookean models, Ogden models more accurately captured the nonlinear material response. For comparable loading rates, shear moduli from mesoscale indentation are consistent with those from macroscale large-strain testing, demonstrating the robustness of the multimodal approach. Based on these observations, we demonstrate the effectiveness of identifying nonlinear material parameters for spinal cord gray and white matter tissue through the simultaneous integration of indentation and large-strain data. Like this, we for the first time include information on both, tissue-type-specific properties as well as large-strain nonlinear effects. Our results demonstrate that a multimodal characterization pipeline can yield a more robust and representative material parameters with important implications for advanced treatment strategies for spinal cord injuries and disease. Statement of Significance: In the growing body of research on the mechanical characterization of brain and spinal cord tissue, discrepancies between measured properties obtained from different testing modalities remain a major challenge. In this study, we use two complementary testing methods - spherical indentation and large-strain compression-tension loading - applied to the same samples. We demonstrate that when the experimental data are analyzed using nonlinear material modeling and finite element simulations, the results from both methods agree well. We for the first time integrate both indentation and large-strain testing data to identify reliable individual material parameters for spinal cord gray and white matter tissue. Our results highlight the robustness of the presented multimodal characterization pipeline for central nervous system tissue.

20 October 2026 in Biophysical Journal
Verified
Journal Article
Open access
ONOskar Neumann
Oskar Neumann
MKMathar Kravikass
Mathar Kravikass
NJNora John
Nora John
RRRahul Gopalan Ramachandran
Rahul Gopalan Ramachandran
PSPaul Steinmann
Paul Steinmann
SBSilvia Budday
Silvia Budday
Functional spinal cord repair in zebrafish is governed by regeneration-favorable biochemical and mechanical cues within the lesion microenvironment. Alterations in extracellular matrix composition and stiffness are closely associated with axon regeneration and its failure. However, experimentally dissecting the interplay between mechanical signals and axonal regrowth in vivo remains technically challenging. Here, we present an agent-based modeling framework to simulate stiffness-mediated axonal growth trajectories across the lesion. We use this model to explore potential mechanisms underlying the characteristic growth patterns observed during zebrafish spinal cord regeneration. Experimental growth profiles of regenerated axons were averaged and compared with mean simulation profiles obtained using different mechanosensing parameter sets. Among the tested parameter combinations, a common parameter set yielded the highest profile overlap at 48 hours post lesion. These exploratory comparisons demonstrate that the model can generate selected features of the observed spatial signal distributions of regenerated axons. Hence, our computational framework provides an in silico platform for investigating the role of mechanical cues in axon regeneration in the injured zebrafish spinal cord.

21 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
ONOskar Fabian Neumann
Oskar Fabian Neumann
MKMathar Kravikass
Mathar Kravikass
NJNora John
Nora John
RRRahul Gopalan Ramachandran
Rahul Gopalan Ramachandran
PSPaul Steinmann
Paul Steinmann
SBSilvia Budday
Silvia Budday
Functional spinal cord repair in zebrafish is governed by regeneration-favorable biochemical and mechanical cues within the lesion microenvironment. Alterations in extracellular matrix composition and stiffness are closely associated with axon regeneration. However, experimentally dissecting the interplay between mechanical signals and axonal regrowth in vivo remains technically challenging. Here, we present an agent-based modeling framework to simulate stiffness-mediated axonal growth trajectories across the lesion. We use this model to explore potential mechanisms underlying the characteristic growth patterns observed during zebrafish spinal cord regeneration. Computational predictions were qualitatively compared with confocal imaging data obtained from larval zebrafish. These phenomenological comparisons revealed a close agreement between simulated and experimentally observed axon growth, indicating that experimentally observed patterns could be governed by transient changes in the stiffness profile of the spinal cord and lesion microenvironment. Hence, our computational framework provides an in silico platform for investigating the role of mechanical cues in axon regeneration in the injured spinal cord.

23 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
ONOskar Neumann
Oskar Neumann
HSHarsh Vardhan Surana
Harsh Vardhan Surana
MHMaik Hintze
Maik Hintze
SKStefanie Kuerten
Stefanie Kuerten
TFThomas Franz
Thomas Franz
SBSilvia Budday
Silvia Budday
The structural integrity of spinal cord tissue and the transmission of mechanical stimuli across the different levels of tissue microarchitecture and varying spatial scales of mechanical loading challenge experimental and computational efforts to accurately model, simulate and interpret tissue mechanics, leading to conflicting findings in existing literature. Here, we demonstrate that the bead size used in spherical indentation tests significantly affects the stiffness ratio of spinal cord gray to white matter, a dependence which we only observe on the transverse plane and not the coronal plane of the tissue. Our study reveals a shift in stiffness ratio such that for smaller spherical indenters gray matter is stiffer than white matter, while for larger indenters, white matter is stiffer than gray matter. The mean relative change from the 100 µ m bead to the 500 µ m bead differed between anatomical planes, with transverse sections showing a decrease in gray matter (−13.3%) and an increase in white matter stiffness (+26.9%), accompanied by a reduction in the gray-to-white matter stiffness ratio from 1.07 to 0.76, whereas coronal sections exhibited increases in both gray (+21.0%) and white matter (+33.8%), along with a change in the ratio from 0.99 to 1.14. These findings contribute to explaining previously contradictory results in the literature and underscore the relevance of spatial scales in mechanical characterization studies.