17 March 2021 in Journal of Neural Engineering
Bioelectronic medicine (BM) is an emerging new approach for developing novel neuromodulation therapies for pathologies that have been previously treated with pharmacological approaches. In this review, we will focus on the neuromodulation of autonomic nervous system (ANS) activity with implantable devices, a field of BM that has already demonstrated the ability to treat a variety of conditions, from inflammation to metabolic and cognitive disorders. Recent discoveries about immune responses to ANS stimulation are the laying foundation for a new field holding great potential for medical advancement and therapies and involving an increasing number of research groups around the world, with funding from international public agencies and private investors. Here, we summarize the current achievements and future perspectives for clinical applications of neural decoding and stimulation of the ANS. First, we present the main clinical results achieved so far by different BM approaches and discuss the challenges encountered in fully exploiting the potential of neuromodulatory strategies. Then, we present current preclinical studies aimed at overcoming the present limitations by looking for optimal anatomical targets, developing novel neural interface technology, and conceiving more efficient signal processing strategies. Finally, we explore the prospects for translating these advancements into clinical practice.
1 April 2020 in Journal of Neural Engineering
FPFrancesco Maria Petrini
+4
Objective. A major challenge in neuroprosthetics is the restoration of sensory-motor hand functions in upper-limb amputees. Neuroprostheses based on the direct re-connection of the peripheral nerves may be an interesting approach for re-establishing the natural and effective bidirectional control of hand prostheses. Recent results have shown that transverse intrafascicular multi-channel electrodes (TIMEs) can restore natural and sophisticated sensory feedback. However, the potential of using TIME-recorded motor intraneural signals to decode grasping tasks has not as yet been explored. Approach. In this study, we show that several hand-movement intentions can be decoded from intraneural signals recorded using four TIMEs implanted in the median and ulnar nerves of an upper limb amputee. Experimental sessions were performed over a week, from day 16 to day 23 after the surgical operation. Intraneural activity was recorded during several hand motor tasks imagined by the subject and processed offline. Main results. We obtained a very high decoding accuracy considering 11 class states (up to 83%). These results confirm that neural signals recorded by multi-channel intraneural electrodes can be used to decode several movement intentions with high accuracy. Moreover, we were able to use same TIME channels for decoding over one week within the first month, even if the stability has to be confirmed during long-term experiments. Significance. Therefore, TIMEs could be used in the future to achieve a complete bidirectional approach exploiting neural pathways, to make a more natural and intuitive new generation of hand prostheses that have a closer resemblance to a healthy hand.
23 September 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Recent studies showed that the carotid sinus nerve (CSN) and the sympathetic nervous system (SNS) are overactivated in type 2 diabetes and that restoring the correct CSN neural activity can re-establish the proper metabolism. However, a robust characterization of the relationship between CSN and SNS neural activities and metabolism in type 2 diabetes is still missing. Here, we investigated the relationship between neural activity of CSN and SNS in control rats and in rats with diet-induced type 2 diabetes and the animal condition during metabolic challenges. We found that the diabetic condition can be discriminated on the basis of CSN and SNS neural activities due to a high-frequency shift in both spectra. This shift is suppressed in the SNS in case of CSN denervation, confirming the role of CSN in driving sympathetic overactivation in type 2 diabetes. Interestingly, the Inter-Burst-Intervals (IBIs) calculated from CSN bursts strongly correlate with perturbations in glycaemia levels. This finding, held for both control and diabetic rats, indicates the possibility of detecting metabolic information from neural recordings even in pathological conditions. Our results suggest that CSN activity could serve as a marker to monitor glycaemic alterations and, therefore, it could be used for closedloop control of CSN neuromodulation. This paves the way to the development of novel and effective bioelectronic therapies for type 2 diabetes.
6 April 2021 in Journal of Neural Engineering
Objective . Recent results have shown the potentials of neural interfaces to provide sensory feedback to subjects with limb amputation increasing prosthesis usability. However, their advantages for decoding motor control signals over current methods based on electromyography (EMG) are still debated. In this study we compared a standard EMG-based method with approaches that use peripheral intraneural data to infer distinct levels of grasping force and velocity in a trans-radial amputee. Approach . Surface EMG (three channels) and intraneural signals (collected with transverse intrafascicular multichannel electrodes, TIMEs, 56 channels) were simultaneously recorded during the amputee’s intended grasping movements. We sorted single unit activity (SUA) from each neural signal and then we identified the most informative units. EMG envelopes were extracted from the recorded EMG signals. A reference support vector machine (SVM) classifier was used to map EMG envelopes into desired force and velocity levels. Two decoding approaches using SUA were then tested and compared to the EMG-based reference classifier: (a) SVM classification of firing rates into desired force and velocity levels; (b) reconstruction of covariates (the grasp cue level or EMG envelopes) from neural data and use of covariates for classification into desired force and velocity levels. Main results. Using EMG envelopes as reconstructed covariates from SUA yielded significantly better results than the other approaches tested, with performance similar to that of the EMG-based reference classifier, and stable over three different recording days. Of the two reconstruction algorithms used in this approach, a linear Kalman filter and a nonlinear point process adaptive filter, the nonlinear filter gave better results. Significance. This study presented a new effective approach for decoding grasping force and velocity from peripheral intraneural signals in a trans-radial amputee, which relies on using SUA to reconstruct EMG envelopes. Being dependent on EMG recordings only for the training phase, this approach can fully exploit the advantages of implanted neural interfaces and potentially overcome, in the medium to long term, current state-of-the-art methods. (Clinical trial’s registration number: NCT02848846).
8 August 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Rodent models are decisive for translational research in healthy and pathological conditions of motor function thanks to specific similarities with humans. Here, we present an upgraded version of the M-Platform, a robotic device previously designed to train mice during forelimb retraction tasks. This new version significantly extends its possibilities for murine experiments during motor tasks: 1) an actuation system for friction adjustment allows to automatically adapt pulling difficulty; 2) the device can be used both for training, with a retraction task, and for assessment, with an isometric task; and 3) the platform can be integrated with a neurophysiology systems to record simultaneous cortical neural activity. Results of the validation experiments with healthy mice confirmed that the M-Platform permits precise adjustments of friction during the task, thus allowing to change its difficulty and that these variations induce a different improvement in motor performance, after specific training sessions. Moreover, simultaneous and high quality (high signal-to-noise ratio) neural signals can be recorded from the rostral forelimb area (RFA) during task execution. With the novel features presented herein, the M-Platform may allow to investigate the outcome of a customized motor rehabilitation protocol after neural injury, to analyze task-related signals from brain regions interested by neuroplastic events and to perform optogenetic silencing or stimulation during experiments in transgenic mice.
1 January 2020 in Journal of Neuroscience Methods