A method to traceably calibrate wideband code-division multiple-access (WCDMA) error vector magnitude (EVM) contributions of a source or a receiver is described using a real-time digital oscilloscope as the reference receiver. The results and uncertainties are presented for a receiver calibrated using four WCDMA sources from different manufacturers. The weighted mean EVM of the receiver at 900 MHz is 0.35 $\pm$ 0.03% at 95% confidence. Measurement results at 1780 and 2510 MHz are also reported.

1 May 2010
Verified
Conference Paper
Closed access
DADavid Adamson
David Adamson
JMJames Miall
James Miall
JHJohn Howes
John Howes
MHMatthew Harper
Matthew Harper
RTRichard Thompson
Richard Thompson
Primary power standards are required to provide traceability for measurements. NPL has recently built a new primary power standard for use in the 75 GHz to 110 GHz band. Compared to NPL's older standard (which has been used for several decades) the new system has a reduced thermal mass and improved thermal isolation. This gives slightly reduced overall uncertainties and an improvement in usability. Improvements in manufacturing technique offer the promise of using a similar design in the 110 GHz to 170 GHz band and work on a calorimeter for this band has begun.

1 December 2008
Verified
Conference Paper
Closed access
DHDavid A. Humphreys
David A. Humphreys
GWGavin Watkins
Gavin Watkins
KMKevin A. Morris
Kevin A. Morris
JMJames Miall
James Miall
Radio Frequency Waveform metrology (RFWM), based on real-time digital oscilloscopes, was used to evaluate the performance of a non-linear E-class amplifier optimized for WCDMA at 840 MHz. A timing error in the modulation signal gave abnormally high EVM values when measured using commercial equipment. The EVM of the source and amplifier were estimated as 0.4% and 2% respectively using RFWM. Simple RFWM evaluation tools show amplifier distortion and may offer insights over parametric measures.

1 July 2012
Verified
Conference Paper
Closed access
DHDavid Humphreys
David Humphreys
JMJames Miall
James Miall
A method to traceably calibrate Wideband Code Division Multiple Access (WCDMA) Error Vector Magnitude (EVM) contributions of a source or receiver is described using a Real-Time Digital Oscilloscope as the reference receiver. The results and uncertainties are presented for a receiver calibrated using four WCDMA sources from different manufacturers. The weighted mean EVM of the receiver at 900 MHz is 0.35 ±0.03 % at 95% confidence.

1 January 2007
Verified
Book Chapter
Closed access
JMJames Miall
James Miall
This is a brief introduction to guided-wave power measurements in the approximate range of a few MHz to several hundreds of GHz, some devices that can be used to measure RF power and the techniques for calibrating these devices.