27 January 2022 in Physical Review A
A modified weak-value-amplification (MWVA) technique to measure a mirror's velocity based on the Vernier effect is proposed. To demonstrate its enhanced sensitivity and higher signal-to-noise ratio (SNR), we use two cascaded Michelson interferometers with similar optical structures. One has a fixed mirror and acts as a fixed part of the Vernier scale, while the other, with a moving mirror, acts as a sliding part of the Vernier scale for velocity sensing. The envelope of the cascaded interferometers shifts much more than a single one with a certain enhancement factor, which is related to the free space range difference between them. In addition, we calculate the SNR based on the Fisher information with both the MWVA and traditional weak-value-amplification (TWVA) techniques. The results show that both the SNR and the sensitivity with our MWVA technique is greater than that of the TWVA technique within the range of our time measurement window. In particular, MWVA can present a viable and effective alternative to the TWVA technique out of the limit of resolution. Furthermore, by using the principles of the Vernier effect, it is applicable and convenient to improve the sensitivity and SNR in measuring other quantities with the TWVA technique.
27 February 2025 in Physical Review Letters
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
29 March 2021 in The European Physical Journal D
3 November 2022 in Physical Review A
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.
6 March 2020 in Physical Review D
We calculate the variation of the chiral condensate in medium with respect to the quark chemical potential and evaluate the pion-nucleon sigma term via the Hellmann-Feynman theorem. The variation of the chiral condensate in medium is obtained by solving the truncated Dyson-Schwinger equation for the quark propagator at finite chemical potential, with various ansätz for the quark-gluon vertex and gluon propagator. We obtain the value of the sigma term , where the (1) represents the systematic error due to our different ansätz for the quark-gluon vertex and gluon propagator. Our result favors a relatively large value and is rather consistent with the recent data obtained by analyzing pion-nucleon scattering and pionic-atom experiments.
29 September 2023 in Physical Review A
The achievement of a larger magneto-optical Kerr effect (MOKE) in nanoscale layered structures is extremely important for both theoretical understandings and practical applications. However, nanoscale layered structures may not always exhibit enhanced MOKE under certain geometries. In this paper, we present a scheme based on weak-value amplification (WVA) for simultaneously detecting and enhancing the Kerr signals in nanoscale layered structures. The Kerr signals can be effectively amplified as the parameters of the preselection in WVA. We numerically investigate the dependence of the thickness of Co in the sample and the sample in the range of 5 nm 50 nm. Our results indicate that the combination of the cavity and WVA can simultaneously amplify the MOKE signals when compared to the application of WVA on the sample and the application of traditional MOKE setup (TMOKES) on the two samples. Importantly, our results highlight that WVA maintains its ability to amplify MOKE signals even in cases where the cavity in the TMOKES scheme fails to enhance the Kerr signals. This signifies the exceptional advantage of WVA in amplifying Kerr signals over TMOKES, regardless of the sample structures and specific MOKE geometries employed.