This paper proposes an adaptive control architecture for maximum power point tracking (MPPT) in photovoltaic systems. MPPT technologies have been used in photovoltaic systems to deliver the maximum available power to the load under changes of the solar insolation and ambient temperature. To improve the performance of MPPT, this paper develops a two-level adaptive control architecture that can reduce complexity in system control and effectively handle the uncertainties and perturbations in the photovoltaic systems and the environment. The first level of control is ripple correlation control (RCC), and the second level is model reference adaptive control (MRAC). By decoupling these two control algorithms, the system achieves MPPT with overall system stability. This paper focuses mostly on the design of the MRAC algorithm, which compensates the underdamped characteristics of the power conversion system. The original transfer function of the power conversion system has time-varying parameters, and its step response contains oscillatory transients that vanish slowly. Using the Lyapunov approach, an adaption law of the controller is derived for the MRAC system to eliminate the underdamped modes in power conversion. It is shown that the proposed control algorithm enables the system to converge to the maximum power point in milliseconds.
This letter reports that the performance of organic solar cells made from blended films of regioregular poly 3-hexylthiophene and methanofullerene can be boosted by introducing single-walled carbon nanotubes (SWCNTs) into the active layer at low concentration. However, the performance degrades at higher SWCNTs concentration. The intensity dependent photocurrent measurement shows that the decreased performance at higher concentration of SWCNTs is attributed to bimolecular recombination in the presence of metallic SWCNTs. Meanwhile, it has been found that the increased performance at low concentration of SWCNTs is due to the increased carrier mobility as semiconducting SWCNTs provide lower resistance pathways.
Reported here is an analytical methodology for modeling the Cdv/dt induced false turn-on in SiC MOSFETs. A Cdv/dt test circuit is utilized to assess the influence of the parasitic device parameters on the magnitude of the induced gate-source voltage during false turn-on. The effect that each parasitic parameter has on the damping of the SiC MOSFET's drain-source voltage is also evaluated. Experimental results are provided to validate the analytical model. The methods presented here will enable design engineers to project the performance of next generation SiC MOSFETs in high dv/dt circuits like the synchronous buck converter.
A chip set for a 40-Gb/s fiber optical communication system has been designed and fabricated. On-wafer measurements have been performed to verify circuit operations. As far as available measurement capabilities show, all circuits are functionally fulfilling specifications for 40-Gb/s operation at less than or equal to 3-V supply voltage. During the design phase especially the influence of interconnects on signal integrity was investigated and the results were implemented for automatic extraction. All the circuits were operational after the first processing round. No redesign was necessary.