Nur Hartini Mohd Taib

Nur Hartini Mohd Taib

Auto-generated profile, based on publicly available information

Nur Hartini Mohd Taib


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Edrine DamuliraEdrine Damulira
Edrine Damulira
MYMuhammad Nur Salihin Yusoff
Muhammad Nur Salihin Yusoff
AOAhmad Fairuz Omar
Ahmad Fairuz Omar
NTNur Hartini Mohd Taib
Nur Hartini Mohd Taib
Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) are used to measure and monitor radiation in medical applications. Of recent, photonic devices have also been adopted. This article evaluates recent research and advancements in the applications of photonic devices in medical radiation detection primarily focusing on four types; photodiodes – including light-emitting diodes (LEDs), phototransistors—including metal oxide semiconductor field effect transistors (MOSFETs), photovoltaic sensors/solar cells, and charge coupled devices/charge metal oxide semiconductors (CCD/CMOS) cameras. A comprehensive analysis of the operating principles and recent technologies of these devices is performed. Further, critical evaluation and comparison of their benefits and limitations as dosimeters is done based on the available studies. Common factors barring photonic devices from being used as radiation detectors are also discussed; with suggestions on possible solutions to overcome these barriers. Finally, the potentials of these devices and the challenges of realizing their applications as quintessential dosimeters are highlighted for future research and improvements.

24 June 2023 in Cancers
Verified
Journal Article
Open access
PDF file
AMAIMAN ABDUL MANAN
AIMAN ABDUL MANAN
NYNoorazrul Yahya
Noorazrul Yahya
NTNur Hartini Mohd Taib
Nur Hartini Mohd Taib
Zamzuri IdrisZamzuri Idris
Zamzuri Idris
HMHanani Abdul Manan
Hanani Abdul Manan
Alteration in the surrounding brain tissue may occur in the presence of a brain tumor. The present study aims to assess the characteristics and criteria of the pattern of white matter tract microstructure integrity alteration in brain tumor patients. The Scopus, PubMed/Medline, and Web of Science electronic databases were searched for related articles based on the guidelines established by PRISMA. Twenty-five studies were selected on the morphological changes of white matter tract integrity based on the differential classification of white matter tract (WMT) patterns in brain tumor patients through diffusion tensor imaging (DTI). The characterization was based on two criteria: the visualization of the tract—its orientation and position—and the DTI parameters, which were the fractional anisotropy and apparent diffusion coefficient. Individual evaluations revealed no absolute, mutually exclusive type of tumor in relation to morphological WMT microstructure integrity changes. In most cases, different types and grades of tumors have shown displacement or infiltration. Characterizing morphological changes in the integrity of the white matter tract microstructures is vital in the diagnostic and prognostic evaluation of the tumor’s progression and could be a potential assessment for the early detection of possible neurological defects that may affect the patient, as well as aiding in surgery decision-making.

31 January 2017 in Sains Malaysiana
Verified
Journal Article
Closed access
NTNur Hartini Mohd Taib
Nur Hartini Mohd Taib
WAWan Ahmad Kamil Wan Abdullah
Wan Ahmad Kamil Wan Abdullah
ISIbrahim Lutfi Shuaib
Ibrahim Lutfi Shuaib
EMEnrico Magosso
Enrico Magosso
SISuzana Mat Isa
Suzana Mat Isa

12 April 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Edrine DamuliraEdrine Damulira
Edrine Damulira
MYMuhammad Nur Salihin Yusoff
Muhammad Nur Salihin Yusoff
AOAhmad Fairuz Omar
Ahmad Fairuz Omar
NTNur Hartini Mohd Taib
Nur Hartini Mohd Taib
Light-emitting diodes (LEDs) could be a potential dosimetry candidate because they are radiation hard, spectrally selective, direct band gap, and low-cost devices. Thus, an LED-based detector prototype was designed and characterized for dosimetry. A 20 × 20 cm 2 array of surface mount device LED chips was sandwiched in photovoltaic mode between two intensifying screens to form a dosimetric system. The system was enclosed in a light-tight air cavity using black vinyl tape. The screens converted diagnostic x-ray beams into fluorescent blue light. LEDs, applied in detector mode, converted the fluorescent light into radiation-induced currents. A digital multimeter converted the analog currents into digital voltage signals. Prototype characterization was executed using (a) IEC 61267’s RQR 7 (90 kVp) and RQR 8 (100 kVp) beam qualities, and (b) low (25 mAs) and high (80 mAs) beam quantities. A standard dosimeter probe was simultaneously exposed with the prototype to measure the prototype’s absorbed dose. In all exposures, the x-ray beams were perpendicularly incident on both the dosimeter and prototype, at a fixed source to detector distance-60 cm. The LED array prototype’s minimum detectable dose was 0.139 mGy, and the maximum dose implemented herein was ∼13 mGy. The prototype was 99.18% and 98.64% linearly sensitive to absorbed dose and tube current–time product (mAs), respectively. The system was ±4.69% energy, ±6.8% dose, and ±7.7% dose rate dependent. Two prototype data sets were 89.93% repeatable. We fabricated an ultrathin (5 mm), lightweight (130 g), and a relatively low-cost LED-based dosimetric prototype. The prototype executed a simple, efficient, and accurate real-time dosimetric mechanism. It could thus be an alternative to the current passive dosimetric systems.

26 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Edrine DamuliraEdrine Damulira
Edrine Damulira
MYMuhammad Nur Salihin Yusoff
Muhammad Nur Salihin Yusoff
SSSuharti Sulaiman
Suharti Sulaiman
NZNur Farah Huda Zulkafli
Nur Farah Huda Zulkafli
NZNur Amiela Zulkifli
Nur Amiela Zulkifli
NANik Kamarullah Ya Ali
Nik Kamarullah Ya Ali
Light-emitting diodes (LEDs) have miscellaneous applications owing to their low cost, small size, flexibility, and commercial availability. Furthermore, LEDs have dual applicability as light emitters and detectors. This study explores the current–voltage (C–V) response of LED strips exposed to diagnostic x-rays. Cold white, warm white, red, green, and blue LED strip colors were tested. Each strip consisted of 12 LED chips and was connected to a multimeter. The variable diagnostic x-ray parameters evaluated were kilovoltage peak (kVp), milliampere-seconds (mAs), and source-to-image distance (SID). The radiation dose was also measured using a dosimeter simultaneously exposed to x-rays perpendicularly incident on the strips. Lastly, the consistency of C–V responses, and any possible degradation after 1–2 months was also analyzed. Each LED strip color was ranked according to its C–V response in each of the investigated parameters. The LED strip color with the best cumulative rank across all the tested parameters was then examined for reproducibility. Our findings revealed that the C–V responses of LED strips are (a) generally low but measurable, (b) inconsistent and fluctuating as a consequence of kVp variations, (c) positively correlated to mAs, (d) negatively correlated to SID, and (e) positively correlated to dose. Overall results suggested cold white LED strip as most feasible for x-ray detection—in comparison to examined colors. Additionally, the reproducibility study using the cold white LED strip found a similar trend of C–V response to all variables except kVp. Outcomes indicate that LED strips have the potential to be exploited for detecting low dose (~0–100 mGy) diagnostic x-rays. However, future studies should be carried out to increase the low C–V signal.

20 March 2018 in International Journal of Current Research in Science, Engineering & Technology
Verified
Journal Article
Closed access
AZAsmat Zahariman
Asmat Zahariman
MAMohd Ibrohim Abdullah
Mohd Ibrohim Abdullah
MRMohammad Khairul Azhar Abdul Razab
Mohammad Khairul Azhar Abdul Razab
NTNur Hartini Mohd Taib
Nur Hartini Mohd Taib
NANik Kamarullah Ya Ali
Nik Kamarullah Ya Ali
WAWan Ahmad Kamil Wan Abdullah
Wan Ahmad Kamil Wan Abdullah