Emre Iseri

Emre Iseri

Auto-generated profile, based on publicly available information

Emre Iseri

KTH Royal Institute of Technology, Stockholm, Sweden

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2021 in Nature Physics
Verified
Journal Article
Closed access
PDF file
HHHiroki Hiroki
Hiroki Hiroki
EIEmre Iseri
Emre Iseri
XWXi Wei
Xi Wei
KKKerem Kaya
Kerem Kaya
GDGiacomo Di Dio
Giacomo Di Dio
WWWouter van der Wijngaart
Wouter van der Wijngaart

10 November 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
EIEmre Iseri
Emre Iseri
MBMichael Biggel
Michael Biggel
HGHerman Goossens
Herman Goossens
PMPieter Moons
Pieter Moons
WWWouter van der Wijngaart
Wouter van der Wijngaart
Established digital bioassay formats, digital PCR and digital ELISA, show extreme limits of detection, absolute quantification and high multiplexing capabilities. However, they often require complex instrumentation, and extensive off-chip sample preparation. In this study, we present a dipstick-format digital biosensor (digital dipstick) that detects bacteria directly from the sample liquid with a minimal number of steps: dip, culture, and count. We demonstrate the quantitative detection of Escherichia coli (E. coli) in urine in the clinically relevant range of 102–105 CFU ml−1 for urinary tract infections. Our format shows 89% sensitivity to detect E. coli in clinical urine samples (n = 28) when it is compared to plate culturing (gold standard). The significance and uniqueness of this diagnostic test format is that it allows a non-trained operator to detect urinary tract infections in the clinically relevant range in the home setting.

11 January 2024 in Microbiology Spectrum
Verified
Journal Article
Open access
EIEmre Iseri
Emre Iseri
SNSara Nilsson
Sara Nilsson
ABAlex Van Belkum
Alex Van Belkum
WWWouter van der Wijngaart
Wouter van der Wijngaart
VÖVolkan Özenci
Volkan Özenci
UTI-lizer is a recent digital format for easy-to-use culture-based detection, preliminary identification, and quantification of bacteria in urine at the point of care (PoC). This study aimed to evaluate the diagnostic accuracy of UTI-lizer tests for detection of bacteriuria caused by five common bacterial species: Escherichia coli , Klebsiella pneumoniae , Enterococcus faecalis , Proteus mirabilis , and Staphylococcus saprophyticus . We evaluated the accuracy of UTI-lizer tests by comparing test results of UTI-lizer with those of current standard bacterial culture-based diagnostics in clinical microbiology laboratories in a retrospective and a prospective study. Comparator methods were classical bacterial culture in combination with matrix-assisted laser desorption/ionization-time of flight mass spectrometry mediated bacterial identification. In the retrospective study, we tested 104 urine samples with in-panel microorganisms, plain urethral microbiota, and culture-negative samples. In the prospective study, we used 137 urine samples within 10 hours of their collection at general practitioner clinics. The retrospective study demonstrated 100% sensitivity and specificity in the detection of bacteriuria, and 98.6% sensitivity and 96.8% specificity in identifying primary pathogens with UTI-lizer when compared to clinical standards. S. saprophyticus and E. coli could not be distinguished. The combined nitrite and esterase test predicted the presence of bacteriuria in only 36.5% of cases. The prospective study demonstrated 100% sensitivity and 89.6% specificity in the detection of significant bacteriuria for in-panel microorganisms with a coverage rate of 88.3% (121/137). This study indicates that digital dipsticks are a promising alternative for the detection of the five main pathogens that cause the vast majority of urinary tract infections (UTIs). The results demonstrate that digital dipsticks have the potential to uniquely provide—in primary care or at the point of care—a UTI diagnostic quality on par with that of current gold-standard testing. The ease of testing, rapid test handling time, and time to result as well as simple test equipment make digital dipsticks an attractive solution for decentralized testing for bacteriuria and with that improvement in UTI diagnostics. These results motivate future studies to validate the use of UTI-lizer at the PoC setting. IMPORTANCE: In this study, we explore the transformative potential of UTI-lizer, an emerging technology not yet commercially available. Our manuscript shows that UTI-lizer is a promising alternative for detecting the five main pathogens that cause urinary tract infections (UTIs). The results also indicate that digital dipsticks have the potential to uniquely provide UTI diagnostic quality on par with that of gold-standard testing, with the added benefits of ease of testing, rapid test handling time, and simple test equipment. This technology can be helpful in quickly ruling out bacterial infections and reducing the unnecessary use of antibiotics, especially in primary care settings or at the point of care. Moreover, the UTI-lizer test can reduce the number of negative urine samples sent to central laboratories, thus easing the burden of UTI diagnostics on the healthcare system. We believe our study, as well as current and upcoming research based on this technology, is highly relevant for clinical microbiologists, microbiology scientists, general practitioners, and urologists.

6 May 2022 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
FMFilipe Marques
Filipe Marques
JHJanosch Hauser
Janosch Hauser
EIEmre Iseri
Emre Iseri
ISIgor Schliemann
Igor Schliemann
WWWouter van der Wijngaart
Wouter van der Wijngaart
NRNiclas Roxhed
Niclas Roxhed
A portable microfluidic sample preparation device that allows inexperienced personnel to perform ROSE of FNA samples.

24 December 2023 in Advanced Functional Materials
Verified
Journal Article
Open access
KKKerem Kaya
Kerem Kaya
AKAlexander Kravberg
Alexander Kravberg
CSClaudia Scarpellini
Claudia Scarpellini
EIEmre Iseri
Emre Iseri
DKDanica Kragic
Danica Kragic
WWWouter van der Wijngaart
Wouter van der Wijngaart
“hot flow in the cold changes shape in a dead world comes matter to life”Programmable matter that allows free shape transfiguration and locomotion on command promises ubiquitous access to objects or functions of interest. Current approaches for the autonomous reshaping of solid objects (smart materials, soft actuators, modular robotics) are limited in spatial resolution and shape. Solid‐liquid phase change pumping as a mechanism for the contactless transfiguring and locomotion of solid objects is introduced. Thin objects are deformed into any intended shape with sub‐millimeter resolution and the ability to freely change their topology is demonstrated, including adding or removing holes, splitting and merging. The unique locomotion of objects through millimeter‐sized constrictions narrower than their body size is demonstrated, followed by restoring the original shape. This approach opens up avenues for developing autonomous programmable matter with free shape transfiguration.