Elise Ivarsen

Elise Ivarsen

Auto-generated profile, based on publicly available information

Elise Ivarsen

Eurofins Vitamin Testing , Ladelundvej 85 , DK-6600 Vejen

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2011 in Organic & Biomolecular Chemistry
Verified
Journal Article
Closed access
PDF file
AJAnna S. Jørgensen
Anna S. Jørgensen
KSKhalil I. Shaikh
Khalil I. Shaikh
GEGerald Enderlin
Gerald Enderlin
EIElise Ivarsen
Elise Ivarsen
SKSurender Kumar
Surender Kumar
PNPoul Nielsen
Poul Nielsen
Four double-headed nucleosides were prepared by the CuAAC reaction. Hereby, a triazole-containing linker connects an additional thymine or adenine to the 2′-position of 2′-deoxyuridine, a thymine to the 5′-position of thymidine and a thymine to the 6′-position of an LNA-thymidine monomer. Whereas no conclusive recognition effects of the additional thymines were found when introduced in LNA or at the 5′-position, both thymine and adenine in the 2′-position were found to stabilise three-way junctions in both dsDNA and DNA : RNA contexts and to give cross-strand interactions in a DNA-duplex, when specifically introduced in a so-called (+1)-zipper motif.

24 November 2012 in Planta
Verified
Journal Article
Closed access
PDF file
AKAnders Kjær
Anders Kjær
FVFrancel Verstappen
Francel Verstappen
HBHarro Bouwmeester
Harro Bouwmeester
EIElise Ivarsen
Elise Ivarsen
XFXavier Fretté
Xavier Fretté
MJMartin Jensen
Martin Jensen

19 March 2021 in Acta Chromatographica
Verified
Journal Article
Open access
EIElise Ivarsen
Elise Ivarsen
CAChristoffer P. Andersen
Christoffer P. Andersen
SJSabine M. Jensen
Sabine M. Jensen
CPCarsten T. Pedersen
Carsten T. Pedersen
ASAnders K. Svaneborg
Anders K. Svaneborg
This study presents the optimization and validation of methods for the analysis of retinol, thiamine, niacin, pyridoxine, folic acid, cyanocobalamin, zinc, and iron in fortified kernels (coated and extruded) and in fortified rice. The analyses were performed by HPLC-UV/FLD/MS and ICP-OES. The optimized methods showed good resolution of the analyte peaks, excellent recovery (87–108%), reproducibility with relative standard deviation (SD) of analyte content between 1.8 and 11% and high correlation coefficient of the calibration curves (R2 > 0.997). Limit of detection was from 2.8 E-4 mg/kg for pyridoxine to 1.26 mg/kg for zinc and limit of quantification was from 9.2 E-4 mg/kg for pyridoxine to 4.21 mg/kg for zinc. Thereby the optimized methods demonstrated reliability and sensitivity in the detection and quantification of these micronutrients and that they are suitable for routine analysis of fortified kernels (coated and extruded) and fortified rice.

17 February 2025 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Open access
MAMarleen van Aardt
Marleen van Aardt
AKAndrew R Komarek
Andrew R Komarek
MRMichael Roche
Michael Roche
EIElise Ivarsen
Elise Ivarsen
Background: The isolation and purification of vitamins A, E, D, and cholesterol from food and feed test materials, for quantitation, is currently a time-consuming and labor-intensive process. It includes separate steps for saponification, extraction, purification, and solvent evaporation. A new instrument (FLEX) was developed that improves and automates all steps involved, and which uses solid-phase extraction (SPE). This study validates the FLEX automated method. Objectives: The objective of this study was to validate the automated method by recovery of standards, analysis of reference materials, comparison against proficiency test materials, and comparison against manual reference methods. Methods: The FLEX instrument automatically adds reagents, mixes, and heats to saponify test materials, filters the digestate, extracts with SPE, and evaporates solvent. Results: The accuracy of the automated FLEX instrument method was confirmed by the agreement with National Institute of Standards and Technology (NIST) reference materials for retinol, α-tocopherol, cholecalciferol, ergocalciferol, and cholesterol. Accuracy was also compared against manual reference methods on 11 different food types that ranged from 4–100% fat, 0–75% protein, and 0–85% carbohydrate. The automated and manual methods were highly correlated with no bias or distortion over the range of test materials. Precision was similar to the manual methods for retinol recovery but improved for α-tocopherol and cholecalciferol analysis. The accuracy of the automated method also was confirmed for feed analysis. Eleven different animal feeds were analyzed in the FLEX instrument and results were highly correlated with Association of American Feed Control Officials proficiency test results. Conclusion: The automated method accurately and efficiently performed the multiple analytical steps necessary for the isolation and purification of the analytes in preparation for chromatographic analysis. Highlights: The automated method was compared against industry standard methods and yielded equivalent results and improved precision. SPE technology was optimized to efficiently elute non-polar analytes, while retaining protein and other medium-polar analytes.