Loreto Quesada

Loreto Quesada

Auto-generated profile, based on publicly available information

Loreto Quesada

Research Institute of Health Sciences (IdISPa), Palma de Mallorca, Spain

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Forensic Science International
Verified
Journal Article
Closed access
IGIsabel Gomila
Isabel Gomila
VLVictoria López-Corominas
Victoria López-Corominas
MPManuela Pellegrini
Manuela Pellegrini
LQLoreto Quesada
Loreto Quesada
EMElena Miravet
Elena Miravet
BBBernardino Barcelò
Bernardino Barcelò

1 April 2017 in Therapeutic Drug Monitoring
Verified
Journal Article
Closed access
PDF file
IGIsabel Gomila
Isabel Gomila
LQLoreto Quesada
Loreto Quesada
VLVictoria López-Corominas
Victoria López-Corominas
JFJulia Fernández
Julia Fernández
MSMiguel Á. Servera
Miguel Á. Servera
BBBernardino Barcelò
Bernardino Barcelò
Chloroquine and hydroxychloroquine are medical drugs used to treat the chemoprophylaxis of malaria and a second-line anti-inflammatory drug. We performed a study of cross-reactivity of chloroquine and hydroxychloroquine in the DRI Amphetamine Assay inspired by a case report of a self-ingestion of chloroquine after a family dispute, that involved the following: (1) an in vitro study with control samples of healthy subjects, (2) an in vivo study with samples of patients with rheumatoid arthritis, and (3) an evaluation of the cross-reactivity of chloroquine and hydroxychloroquine in 3 additional immunoassays. In the case report, the Amphetamine DRI assay resulted positive both at 1000 ng/mL cutoff (1507 and 1137 ng/mL) and at 500 ng/mL cutoff (1178 and 642 ng/mL). Chloroquine urine levels were 103,900 and 100,900 ng/mL at 5 and 9 hours after ingestion. The results with control samples showed a positive cross-reactivity of chloroquine in the DRI Amphetamine Assay (approximately 0.74% and 0.89% at cutoff of 1000 and 500 ng/mL, respectively). Hydroxychloroquine did not cross-react with the DRI Amphetamine Assay up to 1,000,000 ng/mL. In patients treated with chloroquine or hydroxychloroquine, DRI Amphetamine did not produce false-positive results. The comparative assay study showed a positive cross-reactivity of chloroquine in the Emit II Plus Amphetamines Assay with control samples. Chloroquine can cause false-positive results in the DRI Amphetamine Assay when it is present at high concentrations. Hydroxychloroquine did not produce false-positive results neither in the DRI Amphetamine Assay nor in the others immunoassays evaluated.

1 November 2016 in Medicina Clinica
Verified
Journal Article
Closed access
IMIsabel Gomila Muñiz
Isabel Gomila Muñiz
JFJordi Puiguriguer Ferrando
Jordi Puiguriguer Ferrando
LRLoreto Quesada Redondo
Loreto Quesada Redondo