Second Dental Clinic, Department of Oral Implantology Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University, School of Medicine, National Clinical Research Center for Oral Disease, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology Shanghai China
Auto-generated profile, based on publicly available information
Kai Zhao
Second Dental Clinic, Department of Oral Implantology Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University, School of Medicine, National Clinical Research Center for Oral Disease, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology Shanghai China
Objectives: The purpose of this retrospective study was to evaluate the long‐term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT).Material and methods: Twenty‐five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded.Results: In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter‐quartile range: 1.57 mm) to 1.33 mm (inter‐quartile range: 1.98 mm) after a median follow‐up time of 23.00 months (inter‐quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49).Conclusions: Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement.
Background: Abnormalities of some facial bones derived from the ectomesenchyme have been found in ectodermal dysplasia (ED) patients, but the characteristics of the zygoma are unknown.Purpose: Comparison between ED patients and normal individuals to understand the anatomical features of the zygoma in ED patients.Materials and Methods: Thirty patients diagnosed with ED based on clinical features and/or gene sequence tests and 80 normal individuals were recruited from 2016 to 2018. The thickness of the zygomatic body at 12 points on the superior, middle, and inferior areas and the length of four lines were measured on a three‐dimensional cone beam computed tomography image. Differences between ED patients and normal individuals were then compared.Results: The zygomatic thicknesses and lengths were smaller in ED patients than in normal individuals. For ED patients, the largest thicknesses on the superior, middle, and inferior areas of the zygoma were 8.47 ± 1.49, 7.03 ± 1.56, and 5.99 ± 1.22 mm.Conclusion: The development of zygomatic thickness on the inferior area and the zygomatic length were insufficient in ED patients with oligodontia. Consequently, zygomatic hypoplasia presented difficulties for the “quad approach” to zygomatic implants in this group of patients.