Maurilio Marcacci

Maurilio Marcacci

Auto-generated profile, based on publicly available information

Maurilio Marcacci

IRCCS Humanitas Research Hospital Rozzano Milan Italy

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2016 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
Elizaveta KonElizaveta Kon
Elizaveta Kon
GFGiuseppe Filardo
Giuseppe Filardo
Alberto GobbiAlberto Gobbi
Alberto Gobbi
MBMassimo Berruto
Massimo Berruto
LALuca Andriolo
Luca Andriolo
MMMaurilio Marcacci
Maurilio Marcacci
Background: Cartilage lesions of the patellofemoral joint are a challenging condition. Hyaluronan-based matrix-assisted autologous chondrocyte transplantation (MACT) has been shown to offer a significant improvement in the short term but has a tendency to worsen at midterm follow-up. Hypothesis: Patients treated with MACT for lesions of the articular surface of the patellofemoral joint will present further clinical worsening at long-term follow-up. Study Design: Case series; Level of evidence, 4. Methods: Thirty-two patients with full-thickness chondral lesions in the patellofemoral joint were treated with hyaluronan-based MACT and were prospectively evaluated preoperatively and at 2-, 5-, and 10-year follow-up. The mean defect size was 4.45 cm 2 . There were 20 lesions located on the patella and 8 on the trochlea, and 4 patients had multiple lesions: 3 with patellar and trochlear lesions and 1 with patellar and lateral femoral condyle lesions. Results were evaluated using International Knee Documentation Committee (IKDC) subjective scores, EuroQol visual analog scale (EQ VAS) scores, and Tegner scores. Surgical and clinical failures were documented. Results: All scores showed a statistically significant improvement at 2-, 5-, and 10-year follow-up with respect to the preoperative level. No worsening was observed at the last follow-up, and results were stable up to 10 years. The improvement in mean (±SD) outcome scores from preoperatively to 2-, 5-, and 10-year follow-up was as follows: IKDC, from 46.0 ± 19.8 to 77.1 ± 17.4, 72.0 ± 20.4, and 78.6 ± 16.4, respectively; Tegner, from 2.5 ± 1.4 to 4.7 ± 1.8, 4.7 ± 1.6, and 4.4 ± 1.5, respectively; and EQ VAS, from 56.9 ± 18.4 to 81.7 ± 13.2, 79.2 ± 17.9, and 78.9 ± 1.7, respectively. Four patients did not achieve significant clinical improvement, and 1 of these patients required further surgical treatment. All failures were female patients with patellar defects, and 3 of them had degenerative lesions and underwent a previous or combined realignment procedure. Conclusion: The clinical results of hyaluronan-based MACT treatment of chondral lesions of the patellofemoral joint do not worsen over time but remain stable and show a low rate of failure at long-term follow-up.

1 January 2022
Verified
Journal Article
Closed access
GAGiuseppe Anzillotti
Giuseppe Anzillotti
PCPietro Conte
Pietro Conte
BMB Di Matteo
B Di Matteo
EBE M Bertolino
E M Bertolino
MMM Marcacci
M Marcacci
Elizaveta KonElizaveta Kon
Elizaveta Kon

1 April 2008 in Orthopedics
Verified
Journal Article
Closed access
MZMaria L. Zampagni
Maria L. Zampagni
DCDaniela Casino
Daniela Casino
SZStefano Zaffagnini
Stefano Zaffagnini
AVANDREA VISANI
ANDREA VISANI
MMMaurilio Marcacci
Maurilio Marcacci
The carrying angle value and its pathological variations are important in the management of elbow fractures and in the diagnosis of diseases of lateral and medial epicondyles. Few investigators have studied the carrying angle in-vivo. In clinical practice, the carrying angle of the elbow is assessed by radiographs or goniometers, to evaluate reduction of distal humerus or radial head fractures and epicondyles pathologies. This article presents a noninvasive procedure to estimate the carrying angle in full-extension by a 3D digitizer suitable for orthopedic applications. We also performed an experimental analysis of reliability, by comparing repeated acquisitions both by the same operator and by two different operators. Two operators performed the acquisitions on 37 healthy patients. Mean carrying angle was 12.7°±3.8°. Women and men presented a mean carrying angle value of 12.90°±3.95° and 12.40°±3.64°, respectively. Right and left carrying angle values were respectively 12.55°±3.50° and 12.81°±4.11°. Neither limb side ( P =0.76) nor gender significant differences ( P =.57) were found. Mean values were consistent to the literature, interoperator repeatability was good (ICC=0.7) and intraoperator repeatability excellent (ICC=0.85). A further advantage of this methodology is the automatic inclusion of the calculation of the flexion and pronation angle. This evaluation was never included in previous approaches and it could be useful in clinical and rehabilitative fields.

12 October 2015 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Closed access
MBMichele Bianchi
Michele Bianchi
MBMarco Boi
Marco Boi
Nicola Francesco LopomoNicola Francesco Lopomo
Nicola Francesco Lopomo
MMMaria Cristina Maltarello
Maria Cristina Maltarello
FLFABIOLA LISCIO
FABIOLA LISCIO
MMMaurilio Marcacci
Maurilio Marcacci

19 January 2013 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
BMBerardo Di Matteo
Berardo Di Matteo
VTVittorio Tarabella
Vittorio Tarabella
GFGiuseppe Filardo
Giuseppe Filardo
AVAnna Viganò
Anna Viganò
PTPatrizia Tomba
Patrizia Tomba
MMMaurilio Marcacci
Maurilio Marcacci

1 January 2016 in Materials Science and Engineering: C
Verified
Journal Article
Open access
Gregorio MarchioriGregorio Marchiori
Gregorio Marchiori
Nicola Francesco LopomoNicola Francesco Lopomo
Nicola Francesco Lopomo
MBMarco Boi
Marco Boi
MBMatteo Berni
Matteo Berni
MBM. Bianchi
M. Bianchi
MMM. Marcacci
M. Marcacci
Realizing hard ceramic coatings on the plastic component of a joint prosthesis can be strategic for the mechanical preservation of the whole implant and to extend its lifetime. Recently, thanks to the Plasma Pulsed Deposition (PPD) method, zirconia coatings on ultra-high molecular weight polyethylene (UHMWPE) substrates resulted in a feasible outcome. Focusing on both the highly specific requirements defined by the biomedical application and the effective possibilities given by the deposition method in the perspectives of technological transfer, it is mandatory to optimize the coating in terms of load bearing capacity. The main goal of this study was to identify through Finite Element Analysis (FEA) the optimal coating thickness that would be able to minimize UHMWPE strain, possible insurgence of cracks within the coating and stresses at coating-substrate interface. Simulations of nanoindentation and microindentation tests were specifically carried out. FEA findings demonstrated that, in general, thickening the zirconia coating strongly reduced the strains in the UHMWPE substrate, although the 1 μm thickness value was identified as critical for the presence of high stresses within the coating and at the interface with the substrate. Therefore, the optimal thickness resulted to be highly dependent on the specific loading condition and final applications.