Austin MacDonald

Austin MacDonald

Auto-generated profile, based on publicly available information

Austin MacDonald

Brooke Army Medical Center

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
DSDarren L. De Sa
Darren L. De Sa
NHNolan S. Horner
Nolan S. Horner
AMAustin MacDonald
Austin MacDonald
NSNicole Simunovic
Nicole Simunovic
GSGerard Slobogean
Gerard Slobogean
OAOlufemi R. Ayeni
Olufemi R. Ayeni

12 May 2025 in Military Medicine
Verified
Journal Article
Closed access
CNCraig D Nowadly
Craig D Nowadly
JMJoseph K Maddry
Joseph K Maddry
CVCollin R Vargas
Collin R Vargas
AMAustin G MacDonald
Austin G MacDonald
YMYevgeniy M Maksimenko
Yevgeniy M Maksimenko
BLBrit J Long
Brit J Long
Introduction: The widespread adoption of unmanned aircraft systems (UAS) has fundamentally altered modern combat, expanding beyond reconnaissance to include offensive strikes. Their affordability and accessibility have enabled both state and nonstate actors to integrate UAS into military operations. Despite their increasing use, the impact of UAS on military medical operations remains underrepresented in the literature. This review contextualizes current UAS capabilities and examines their implications for military medicine. Materials and Methods: The authors conducted a narrative review using PubMed, Google Scholar, and open-source materials to evaluate UAS applications in military medicine. Search terms included “drone,” “unmanned aircraft system,” “UAV,” “UAS,” “medical,” “military,” and “resuscitation.” Resources published through December 2024 were screened for relevance. Given limited availability of peer-reviewed research involving the implications of UAS in combat, additional data were drawn from military leadership interviews, media reports, and third-party conflict analyses. Results: This review identified 5 thematic areas: adversarial UAS impacts on force protection and medical evacuation; UAS use for medical resupply; UAS applications in casualty evacuation; integration challenges with airspace control systems; and risks of interference with medical systems from electronic warfare and counter-UAS measures. Discussion: The rapid proliferation of UAS has created both challenges and opportunities across the military medical continuum. UAS have demonstrated effectiveness in delivering medical supplies, including blood products, critical medications, and portable medical equipment. Deployment of this technology onto the battlefield could significantly reduce logistical constraints in austere environments. Early casualty evacuation (CASEVAC) applications have shown promise, but there are numerous operational limitations including payload capacity, lack of onboard medical personnel, and the need for triage protocols tailored to autonomous evacuation. Additionally, adversarial UAS use presents significant risks to medical operations. Persistent aerial surveillance compromises force protection, while precision strikes and the coordinated use of large numbers of UAS threaten the ability to safely provide point-of-injury care, prolonged field care, CASEVAC, and medical evacuation. These emerging threats challenge long-held assumptions about air superiority and rapid evacuation capabilities. Counter-UAS technologies, electronic warfare, and emerging ethical considerations introduce further complexities to medical operations. Conclusions: As UAS continue to shape the battlefield, military healthcare systems must adapt to both the capabilities and threats they present. Ongoing research, operational testing, and regulatory developments will be critical in integrating UAS into military medicine while mitigating their risks to patient care and medical logistics.

1 January 2022 in Journal of Orthopaedic Business
Verified
Journal Article
Open access
JHJoshua Hansen
Joshua Hansen
CLCorbin Lee
Corbin Lee
BHBryson Hewins
Bryson Hewins
AMAustin MacDonald
Austin MacDonald
ARAustin Rasmussen
Austin Rasmussen
BFBrenton Franklin
Brenton Franklin
Objectives: To compare objective costs between an in-house developed arthroscopy simulator and commercially available options. Design: Cost analysis. Setting: Orthopaedic graduate medical education. Patients/Participants: Eight board-certified orthopaedic surgeons and nineteen novice learners. Intervention: Simulation Training. Main outcome measurement: Cost difference between an in-house developed simulator and a commercially available simulator. Results and conclusions: Significant price differences exist between in-house simulator production cost and commercially available simulators. Low-cost, in-house simulators improve access to arthroscopic simulation training for novice learners by reducing up front cost by 29% and reducing recurring costs by over 90% when compared to a similar commercially available option. Level of Evidence: IV; Cost Analysis Keywords: Education; Simulation; Orthopaedics; Arthroscopy; Simulation Based Learning Theory (J Ortho Business Jan 2022;2(1):7-9)

18 March 2026 in Wilderness & Environmental Medicine
Verified
Journal Article
Closed access
HBHayley N. Brawley
Hayley N. Brawley
JRJohn F. Reichard
John F. Reichard
KSKhaled Shennara
Khaled Shennara
DLDennis Lovett
Dennis Lovett
LBLyle Babcock
Lyle Babcock
CNCraig Nowadly
Craig Nowadly
Introduction: Pharmaceutical stability is a key concern for space missions, where radiation, microgravity, and prelaunch repackaging may accelerate drug degradation. While prior studies examined medications in environmentally controlled spacecraft, data on vacuum exposure are limited. The Polaris Dawn mission provided an opportunity to evaluate drug content following depressurization of the Dragon spacecraft and exposure to the vacuum of space during extravehicular activity. Methods: Nineteen medications (13 repackaged solid, 6 liquid) flew as part of the SpaceX medical kit and were analyzed with lot-matched terrestrial controls. All samples underwent ultra-performance liquid chromatography mass spectrometry analysis upon return. The primary outcome was the percent difference in active pharmaceutical ingredient (API) between vacuum exposure and ground controls. A secondary outcome was the absolute API content expressed as a percentage of labeled dosage. Results: Seventeen of the 19 flown medications demonstrated a < 5% mean API difference between spaceflight and lot-matched terrestrial controls, remaining within the prespecified threshold for clinical significance. Seven medications showed statistically significant differences ( p < 0.05) between the 2 groups, yet all but one medication remained within this 5% range. Against the narrow 95%–105% of labeled dosage criterion, 10 ground controls and 11 spaceflight-exposed medications fell outside this range. Expanding to the broader 80%–120% range, nearly all medications were within acceptable limits. Conclusions: Short-duration spaceflight with vacuum exposure resulted in modest differences in drug content between spaceflight and terrestrial samples. However, high concordance suggests no clinically meaningful degradation, supporting the feasibility of repackaged pharmaceuticals for commercial and exploratory missions.

1 October 2022 in Journal of Orthopaedic Business
Verified
Journal Article
Open access
JHJoshua Hansen
Joshua Hansen
CLCorbin Lee
Corbin Lee
BHBryson Hewins
Bryson Hewins
AMAustin MacDonald
Austin MacDonald
ARAustin Rasmussen
Austin Rasmussen
BFBrenton Franklin
Brenton Franklin
Objectives: To develop and validate a novel, low-cost shoulder arthroscopy partial task trainer. Study Design: Cross-sectional study Methods: A low-cost arthroscopy model was created to simulate navigation and triangulation skills in conjunction with ABOS-certified Orthopaedic surgeons' input. Each participant performed three trials of simulated labral repair and performance data was compared between experienced surgeons and novice medical students. Results: A total of 8 orthopaedic surgeons in the experienced group and 18 medical students in the novice group participated in the study. The average age of the experienced group was 43.1 years old, with 8.3 years of post-residency experience. The average age of the novice group was 24.3 years. The experienced group completed the simulation task faster than the novice group (16.6±7.6 vs. 96.4 ±102.2 seconds; p<0.001). Conclusion: The shoulder arthroscopy model demonstrated significant differences in performance between experienced orthopaedic surgeons and novices when used to assess a standardized basic arthroscopic technical skill. This low-cost trainer discriminates between varying skill levels and may be an effective option for simulation training of arthroscopic fundamentals to novice learners. Level of Evidence: III, Case Control Keywords: Arthroscopy, Simulation, Validity Evidence, Orthopaedics, Graduate Medical Education (J Ortho Business 2022; Volume 2, Issue 4:pages 1-4)