Jose Vera

Jose Vera

Auto-generated profile, based on publicly available information

Jose Vera

DNV Columbus Inc

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Cleaner Production
Verified
Journal Article
Closed access
GLGuanlan Liu
Guanlan Liu
FAFrancois Ayello
Francois Ayello
JVJose Vera
Jose Vera
RERick Eckert
Rick Eckert
PBPrabhas Bhat
Prabhas Bhat

14 March 2010
Verified
Conference Paper
Closed access
SHSandra E Hernandez
Sandra E Hernandez
ZZZiru Zhang
Ziru Zhang
JVJose Vera
Jose Vera
RWRichard C Woollam
Richard C Woollam
As part of an internal Research and Development effort, the company’s recommended CO2 corrosion model has been updated. The model is being updated from the semi-empirical models of de Waard et al. to a more mechanistic approach, which models each of the cathodic and anodic reactions within a common framework based on the developments of Gray, Nesic, and Nordsveen et al. Establishing a consistent internal framework allows the corrosion model to be expanded beyond the effects of just CO2 (H2CO3 and H+ reduction) to include the effects of acetic acid (HAc) and O2. All these effects are treated consistently within the water chemistry, flow and electrochemistry modules. Also, recommendations are made in terms of corrosion inhibition limits.

13 March 2011
Verified
Conference Paper
Closed access
ZZZiru Zhang
Ziru Zhang
SHSandra Hernandez
Sandra Hernandez
RWRichard Woollam
Richard Woollam
JVJose Vera
Jose Vera
YSYuhua Sun
Yuhua Sun
Previously the development and implementation of a new mechanistic model for oil and gas production environments was described. This initial development was a single point model that predicted the CO2 corrosion rate for a given set of conditions. The model has subsequently been further developed to simulate the change in water chemistry and associated corrosion rate along the length of a flow line. As a volume of water moves along the flow line the water chemistry is modified as a result of the flux of iron ions from the corroding pipe wall surface. The associated change in pH from the addition of ferrous ions further influences the CO2 equilibrium. These two effects, varying pH and CO2 equilibrium, combined in-turn to affect the predicted corrosion rate. The model simulates the changing water chemistry and corrosion rate by repeatedly recalculating the mechanistic corrosion rate model for small increments of time. The water chemistry and corrosion rate profiles for prototypical flow line conditions are presented and discussed.