Lucas Paixão

Lucas Paixão

Auto-generated profile, based on publicly available information

Lucas Paixão

Federal University of Minas Gerais

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
TFT.C.F. Fonseca
T.C.F. Fonseca
BMB.M. Mendes
B.M. Mendes
MLM.A.S. Lacerda
M.A.S. Lacerda
LSL.A.C. Silva
L.A.C. Silva
LPL. Paixão
L. Paixão
JJJ.P. R. Junior
J.P. R. Junior

1 February 2020 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
TFT.C.F. Fonseca
T.C.F. Fonseca
PAP.C.G. Antunes
P.C.G. Antunes
MBM.C.L. Belo
M.C.L. Belo
FBF. Bastos
F. Bastos
TCT.P. Campos
T.P. Campos
HYH. Yoriyaz
H. Yoriyaz

23 October 2018 in Medical Physics
Verified
Journal Article
Closed access
PDF file
ASAbner D. Soares
Abner D. Soares
LPLucas Paixão
Lucas Paixão
AFAlessandro Facure
Alessandro Facure

1 December 2015 in Radiologia Brasileira
Verified
Journal Article
Open access
PDF file
LPLucas Paixão
Lucas Paixão
BOBruno Beraldo Oliveira
Bruno Beraldo Oliveira
CVCarolina Viloria
Carolina Viloria
MOMarcio Alves de Oliveira
Marcio Alves de Oliveira
MTMaria Helena Araújo Teixeira
Maria Helena Araújo Teixeira
MNMaria Do Socorro Nogueira
Maria Do Socorro Nogueira
Key words: Mammography; X-ray spectra; HVL; Monte Carlo

10 May 2012 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
LPLucas Paixão
Lucas Paixão
AFAlessandro Facure
Alessandro Facure
ASAna Maria M. Santos
Ana Maria M. Santos
ASAdriano Márcio dos Santos
Adriano Márcio dos Santos
SGSuely Epsztein Grynberg
Suely Epsztein Grynberg
In prostate cancer treatment, there is an increasing interest in the permanent radioactive seeds implant technique. Currently, in Brazil, the seeds are imported with high prices, which prohibit their use in public hospitals. A ceramic matrix that can be used as a radioisotope carrier and radiographic marker was developed at our institution. The ceramic matrix is distinguished by the characteristic of maintaining the radioactive material uniformly distributed in its surface. In this work, Monte Carlo simulations were performed in order to assess the dose distributions generated by this prototype seed model, with the ceramic matrix encapsulated in titanium, in the same way as the commercial 6711 seed. The obtained data was assessed, as described in the TG-43U1 report by the American Association of Physicists in Medicine, for two seed models: (1) the most used model 6711 source — for validation and comparison, and (2) for the prototype model with the ceramic matrix. The dosimetric parameters dose rate constant, Λ, radial dose function, gL(r) , and anisotropy function, F(r,θ), were derived from simulations by the Monte Carlo method using the MCNP5 code. A Λ 0.992 ( ?2.33% ) cGyh?1U?1 was found for the prototype model. In comparison with the 6711 model, a lower dose fall-off on transverse axis was found, as well as a lower dose anisotropy for the radius r=?0.25?cm . In general, for all distances, the prototype seed model presents a slightly larger anisotropy between 0??????<?50? and anisotropy similar to the 6711 model for ????50? . The dosimetric characteristics of the prototype model presented in this study suggest that its use is feasible. Because of the model's characteristics, seeds of lower specific activity iodine might be necessary which, on the other hand, would help to reduce costs. However, it has to be emphasized that the proposed source is a prototype, and the required (AAPM prerequisites) experimental study and tolerance manufacturer values are pending for future studies. PACS numbers: 87.53.Jw, 87.55.K

28 January 2019 in Brazilian Journal of Radiation Sciences
Verified
Journal Article
Open access
PDF file
LPLucas Paixão
Lucas Paixão
BMBruno Melo Mendes
Bruno Melo Mendes
TFTelma Cristina Ferrera Fonseca
Telma Cristina Ferrera Fonseca
The aim of this work is to validate an in-house tool which writes voxel phantoms input files according to EGSnrc C++ class library (egspp) for Monte Carlo simulations. This tool was developed to read a phantom binary file and write a voxel phantom input deck file according to egspp structures. For the validation of the new tool, three voxel phantoms from literature considering different levels of complexity were used. They are the DM_BRA mouse phantom, Golem anthropomorphic phantom, and Case 5 XCAT model phantom from AAPM TG 195 report. For the different cases of study, internal and external photon sources were set and the energy deposition for different source and target tissue/organs were calculated. The results showed good agreement when comparing to dose calculates obtained with other Monte Carlo codes and published in the literature. The new tool was then validated for the egspp Monte Carlo studies with voxel phantoms.