17 June 2022 in Journal of Patan Academy of Health Sciences
Introduction: Non-contrasted computed tomography scan for kidney, ureter, and bladder (CT KUB) for diagnosis of urolithiasis is important for accurate diagnosis, followup, and management. Unlike USG, CT KUB has more diagnostic yield in urolithiasis and other incidental findings. This study aims to evaluate the use of the CT KUB in suspected urolithiasis, presented with severe flank pain. Method: A retrospective observational study was carried out in the Department of Radiology and Imaging, Patan Hospital, Nepal.TheCT KUB reports of patients with suspected urolithiasis from a period of 3 years from Jan 2017 to Jan 2020 were analyzed for evidence of urolithiasis and secondary signs of obstruction as ‘diagnostic’ of CT KUB. Other incidental radiological findings were further analysed and categorized into urinary and extra-urinary. Ethical approval was obtained.Association of USG and CT KUBwas analysed using Chi-square test,with p value<0.05considered statistically significant. Result: Total of 414 CT KUB reports were analysed, 230(55.6%) males, 314 patients had USG before CT KUB. Considering CT KUB as a gold standard for diagnois of urolithiasis, the accuracy of ultrasound was found to be 85.03% and sensitivity is 94.09% and specificity of 27.9%. Conclusion: Majority of the patients included in the study had ultrasound done before CT KUB. The sensitivity of ultrasound was significant considering CT KUB as a gold standard in diagnosis of urolithaisis.
30 December 2022 in Journal of Patan Academy of Health Sciences
Introduction: There are many potential anatomic configurations of celiac axis and hepatic artery. Michel’s classified hepatic arterial variations in 10 categories. Knowledge about these variations in patient is invaluable before surgery. Multidetector computed tomography (MDCT) can accurately depict the vascular anatomy of celiac axis and hepatic artery non-invasively. The aim of this study was to find out the prevalence of different types of anatomical variation of celiac axis and hepatic artery in patients undergoing multiphase CT. Method: Cross-sectional, prospective study was done in Department of Radiology, Patan Hospital, Patan Academy of Health Sciences. MDCT of abdomen of 178 patients with arterial phase images done between December 2021 and March 2022 were evaluated for arterial anatomy of celiac axis and hepatic artery. Arterial anatomy was categorized according to Michel’s classification. Prevalence of each variant anatomy and gender wise prevalence were calculated. Results: CT scans of 178 patients were evaluated out of which 94 were male and 84 were female. Among these individuals 133 (74.7%) had normal anatomy (Type I) and 45 (25.3%) had some sort of variant anatomy. Type III was commonest type of variant anatomy seen in 18 (10.1%) individuals. We found 6(3.4%) individuals with the anatomy other than classified by Michel. Conclusion: There are multiple variation in of celiac axis and hepatic artery anatomy in our population. Knowledge of such anatomical variation will be of great importance for surgeon and interventional radiologist for planning of surgical or vascular procedures and to prevent vascular complication.
22 September 2025 in Nepalese Journal of Radiology
Introduction: Pulmonary Tuberculosis is a common health problem in our country. It is one of the top 10 causes of death in Nepal. The diagnostic guidelines are primarily based on Acid Fast Baccili (AFB) smear on sputum and Gene Xpert test. The objective of this study is to determine the diagnostic accuracy of HRCT chest in pulmonary tuberculosis.Methods: This was a retrospective study conducted in Patan Hospital from January 2020 to December 2024who underwent HRCT chest in the radiology department for suspected tuberculosis and its findings were correlated with AFB smear and Gene Xpert test.Results: A Total of 486 cases underwent HRCT chest for suspected cases of Pulmonary Tuberculosis. Diagnostic accuracy of HRCT chest in diagnosing active PTB was 69.75% with sensitivity (95.8%), specificity (54.63%), positive predictive value (55%), and negative predictive value (95.73%).Conclusions: This study concluded that HRCT chest has high diagnostic accuracy in diagnosing disease activity of pulmonary tuberculosis.
31 December 2025 in Journal of Patan Academy of Health Sciences
Introduction: Nephrolithiasis is most common cause of renal colic encountered. Computed Tomography of kidneys, ureters and bladder (CT-KUB) was found to be extremely sensitive and specific for ureteric calculi. This study aimed to compare the diagnostic performance of ultrasonography ( USG) and CT-KUB in patients presenting with renal colic based on previous studies by Sharad Kondekar, Iqbal Minne & Doaa N Anas, Khaled Elshafey et.al. Method: This is a retrospective study. The USG and CT-KUB findings of 2574 patients were retrospectively analyzed over four years. The data was compiled using XLSX Spreadsheet. Sensitivity, specificity, diagnostic accuracy, positive predictive value and negative predictive values of USG were calculated taking CT-KUB as the gold standard. Result: In 2574 sets of data, the majority of patients were ≤ 30 years old with males predominating. In 2269 cases, renal calculi were detected in both USG and CT-KUB and CT-KUB alone detected renal calculi in 2554 cases. USG detected maximum 1435 cases with 5-10mm sized renal calculi and CT-KUB too detected maximum of 5-10 mm calculi in 1430 cases. The sensitivity, specificity, diagnostic accuracy, positive predictive value and negative predictive values of USG taking CT-KUB as the gold standard, were 88.21%, 17.6%. 87.75%, 99.38% and 0.98% respectively. Conclusion: Although CT-KUB exposes patients to ionizing radiation, it remains the gold standard due to its higher diagnostic accuracy. USG, while less specific, may serve as an initial, no-invasive screening tool.
1 October 2026 in BMJ Open
Objectives: To evaluate the diagnostic accuracy of a publicly available DenseNet-121 convolutional neural network (TorchXRayVision) for triaging chest radiographs of health assessment applicants at a tertiary hospital in Nepal. Design: Prospective, single-centre, shadow-mode diagnostic accuracy validation study. Reported in accordance with the Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015 checklist and STARD-Artificial Intelligence (AI)/Developmental and Exploratory Clinical Investigations of DEcision support systems driven by Artificial Intelligence (DECIDE-AI) guidelines. Setting: Department of Radiology and Imaging, Patan Academy of Health Sciences/Patan Hospital, Lalitpur, Nepal. Participants: 826 consecutive health assessment applicants (foreign employment predeparture medical examination and student migration) undergoing chest radiography from 5 June 2026 to 20 June 2026 inclusive (16 days). Two cases were excluded due to Digital Imaging and Communications in Medicine technical failure. Index test: DenseNet-121 algorithm (TorchXRayVision library, densenet121-res224-all pretrained weights). A maximum aggregated pathology probability score was derived per radiograph and compared against a post hoc derived threshold of 0.6258 (selected as the highest threshold achieving the prespecified ≥95% sensitivity criterion). Reference standard: Single-reader-per-case review by one of three radiologists—two board-certified radiodiagnosticians (LS: 276 cases; DM: 275 cases) and one radiology resident (UB: 275 cases)—each blinded to AI output, using a standardised data collection worksheet capturing binary classification (abnormal/normal) and free-text findings. Results: Of 826 radiographs, 41 (4.97%) were classified as abnormal by the reference standard. At the post hoc derived threshold of 0.6258, the DenseNet-121 algorithm achieved: sensitivity 95.12% (95% CI 83.9% to 98.7%), specificity 77.2% (95% CI 74.1% to 80.0%), area under the receiver operating characteristic curve 0.9583 (95% bootstrap CI 0.9225 to 0.9843), negative predictive value (NPV) 99.67% (95% Wilson CI 98.8% to 99.9%), positive predictive value 17.89% (95% Wilson CI 13.4% to 23.5%) and Cohen’s κ 0.237 (95% bootstrap CI 0.174 to 0.304). Brier score was 0.3621 (null Brier 0.0472) and expected calibration error was 0.564, confirming calibration failure due to score compression (range 0.52–0.72) despite preserved discrimination. The sensitivity estimate should be interpreted with caution given the relatively small number of reference-standard positives (n=41); the Wilson CI width of 14.8 percentage points (83.9–98.7%) reflects substantial uncertainty around this point estimate. Cross-validated results: 10-fold cross-validation yielded bias-corrected sensitivity 95.12% (95% Wilson CI 83.9% to 98.7%; optimism 0.00 pp) and specificity 75.80% (95% Wilson CI 72.7% to 78.7%; optimism+1.40 pp), confirming by internal validation that primary metrics are not materially inflated by circular optimisation; independent external validation was not performed. Conclusions: The DenseNet-121 algorithm demonstrated high point-estimate sensitivity and excellent discrimination for chest radiograph triage in a Nepali health-assessment population, supporting its potential as a radiographic abnormality rule-out triage tool (NPV 99.67%); this does not constitute microbiological exclusion of active pulmonary tuberculosis. Systematic score compression—preserved discrimination despite calibration shift—is a quantifiable marker of low- and middle-income country distributional shift. Prospective local calibration studies and independent external validation are warranted before operational deployment.