24 May 2019 in Pediatric Cardiology
4 February 2021 in Artificial Organs
1 January 2018 in HeartRhythm Case Reports
18 March 2022 in Interactive CardioVascular and Thoracic Surgery
Atrial function in Fontan patients is unknown. Our goal was to report the relationship of atrial function with the cardiac index and atrial function and clinical outcome through longer follow-up periods. Twelve patients were followed up for over 20 years after their first Fontan operation. Atrial function, including the expansion index, atrial ejection fraction, passive ejection fraction and active ejection fraction, was examined using cardiac computed tomography. The relationship of atrial function with the cardiac index and failing Fontan patients was analysed. Twelve Fontan patients were included. The median follow-up period after the first Fontan operation was 27 (range, 21-33) years, and the median age of those examined was 33.5 (range, 24-60) years. There were 6 male patients (50%). The cardiac index showed a significant positive correlation with the expansion index (P = 0.02), the atrial ejection fraction (P = 0.035), and the active ejection fraction (P = 0.013). The expansion index (39.2 ± 19.6 vs 64.1 ± 3.9), atrial ejection fraction (26.6 ± 10.9 vs 39.0 ± 1.5%), booster pump (15.6 ± 9.0 vs 31.3 ± 3.5) and cardiac index (2.1 ± 0.3 vs 2.5 ± 0.2 L/min/m2) were significantly lower in patients with a history of arrhythmia than in patients without a history of arrhythmia (P < 0.05). The expansion index (23.5 ± 13.5 vs 59.5 ± 8.7), atrial ejection fraction (18.1 ± 8.6 vs 37.1 ± 3.7) and active ejection fraction (7.3 ± 2.7 vs 27.7 ± 5.2) were significantly lower in failing Fontan patients than in non-failing Fontan patients (P < 0.01). Patients with atrial arrhythmia and signs of Fontan failure have lower atrial function than those without.
11 July 2020 in Surgical Case Reports
Background: Diaphragmatic hernia is a rare complication of ventricular assist device (VAD), mainly developing after explantation of the device. We herein report a case of diaphragmatic hernia that developed following the implantation of VAD. Case presentation: A 4-month-old girl with a diagnosis of dilated cardiomyopathy underwent VAD implantation for a bridge to heart transplantation. Three months later, intermittent vomiting developed, and left-sided diaphragmatic hernia was confirmed on plain X-ray and computed tomography. Without any findings of ischemia, we performed elective thoracoscopic repair of the diaphragmatic hernia. In the right decubitus position, thoracoscopy revealed the small intestine to be herniated into the left thorax. After reduction of the herniated intestine, the defect of the diaphragm (3 × 2 cm in size) was directly closed with interrupted non-absorbable sutures. Her postoperative course was uneventful. Conclusion: Thoracoscopic repair of diaphragmatic hernia associated with VAD implantation may be a safe approach.
24 January 2025 in Cardiology in the Young
A 50-year-old man presented with shortness of breath. The patient underwent ventricular septation for a single ventricle with L-malposition of the great arteries at 6 years of age. Examinations revealed that the calcified patch for septation was torn and perforated, resulting in a left-to-right shunt. We report a rare case of a single ventricle who survived after septation 40 years ago and underwent the reoperation due to a torn calcified patch.