1 August 2016 in Computers & Operations Research
In accordance with Basel Capital Accords, the Capital Requirements (CR) for market risk exposure of banks is a nonlinear function of Value-at-Risk (VaR). Importantly, the CR is calculated based on a bank’s actual portfolio, i.e. the portfolio represented by its current holdings. To tackle mean-VaR portfolio optimization within the actual portfolio framework (APF), we propose a novel mean-VaR optimization method where VaR is estimated using a univariate Generalized AutoRegressive Conditional Heteroscedasticity (GARCH) volatility model. The optimization was performed by employing a Nondominated Sorting Genetic Algorithm (NSGA-II). On a sample of 40 large US stocks, our procedure provided superior mean-VaR trade-offs compared to those obtained from applying more customary mean-multivariate GARCH and historical VaR models. The results hold true in both low and high volatility samples
1 March 2017 in European Journal of Operational Research
1 January 2014 in Computer Science and Information Systems
In this paper we solve the problem of static portfolio allocation based on historical Value at Risk (VaR) by using genetic algorithm (GA). VaR is a predominantly used measure of risk of extreme quantiles in modern finance. For estimation of historical static portfolio VaR, calculation of time series of portfolio returns is required. To avoid daily recalculations of proportion of capital invested in portfolio assets, we introduce a novel set of weight parameters based on proportion of shares. Optimal portfolio allocation in the VaR context is computationally very complex since VaR is not a coherent risk metric while number of local optima increases exponentially with the number of securities. We presented two different single-objective and a multiobjective technique for generating mean-VaR efficient frontiers. Results document good risk/reward characteristics of solution portfolios while there is a trade-off between the ability to control diversity of solutions and computation time.
1 November 2011 in Journal of Biomechanical Engineering
Low Reynolds number airflow in the pulmonary acinus and aerosol particle kinetics therein are significantly conditioned by the nature of the tidal motion of alveolar duct geometry. At least two components of the ductal structure are known to exhibit stress-strain hysteresis: smooth muscle within the alveolar entrance rings, and surfactant at the air-tissue interface. We hypothesize that the geometric hysteresis of the alveolar duct is largely determined by the interaction of the amount of smooth muscle and connective tissue in ductal rings, septal tissue properties, and surface tension-surface area characteristics of surfactant. To test this hypothesis, we have extended the well-known structural model of the alveolar duct by Wilson and Bachofen (1982, “A Model for Mechanical Structure of the Alveolar Duct,” J. Appl. Physiol. 52 (4), pp. 1064–1070) by adding realistic elastic and hysteretic properties of (1) the alveolar entrance ring, (2) septal tissue, and (3) surfactant. With realistic values for tissue and surface properties, we conclude that: (1) there is a significant, and underappreciated, amount of geometric hysteresis in alveolar ductal architecture; and (2) the contribution of smooth muscle and surfactant to geometric hysteresis are of opposite senses, tending toward cancellation. Quantitatively, the geometric hysteresis found experimentally by Miki (1993, “Geometric Hysteresis in Pulmonary Surface-to-Volume Ratio during Tidal Breathing,” J. Appl. Physiol. 75 (4), pp. 1630–1636) is consistent with little or no smooth muscle tone in anesthetized rabbits in control conditions, and with substantial smooth muscle activation following methacholine challenge. The observed local hysteretic boundary motion of the acinar duct would result in irreversible acinar flow fields, which might be important mechanistic contributors to aerosol mixing and deposition deep in the lung.
24 April 2008 in Journal of Biochemical and Biophysical Methods
1 March 2011 in Acta Physiologica Hungarica
In this study we performed laboratory treadmill protocols of increasing load. Heart rate was continuously recorded and blood lactate concentration was measured for determination of lactate threshold by means of LTD-max and LT4.0 methods.Our results indicate that the shape of heart rate performance curve (HRPC) during incremental testing depends on the applied exercise protocol (change of initial speed and the step of running speed increase, with the constant stage duration). Depending on the applied protocol, the HRPC can be described by linear, polynomial (S-shaped), and exponential mathematical expression.We presented mathematical procedure for estimation of heart rate threshold points at the level of LTD-max and LT4.0, by means of exponential curve and its relative deflection from the initial trend line (tangent line to exponential curve at the point of starting heart rate). The relative deflection of exponential curve from the initial trend line at the level of LTD-max and/or LT4.0 can be defined, based on the slope of the initial trend line. Using originally developed software that allows mathematical analysis of heart rate-load relation, LTD-max and/or LT4.0 can be estimated without direct measurement of blood lactate concentration