19 February 2021 in PLOS Computational Biology
In tumor metastasis, the margination and adhesion of tumor cells are two critical and closely related steps, which may determine the destination where the tumor cells extravasate to. We performed a direct three-dimensional simulation on the behaviors of the tumor cells in a real microvascular network, by a hybrid method of the smoothed dissipative particle dynamics and immersed boundary method (SDPD-IBM). The tumor cells are found to adhere at the microvascular bifurcations more frequently, and there is a positive correlation between the adhesion of the tumor cells and the wall-directed force from the surrounding red blood cells (RBCs). The larger the wall-directed force is, the closer the tumor cells are marginated towards the wall, and the higher the probability of adhesion behavior happen is. A relatively low or high hematocrit can help to prevent the adhesion of tumor cells, and similarly, increasing the shear rate of blood flow can serve the same purpose. These results suggest that the tumor cells may be more likely to extravasate at the microvascular bifurcations if the blood flow is slow and the hematocrit is moderate.
1 March 2020 in Physics of Fluids
Blood plasma separation may be one of the most frequent operations in daily laboratory analysis so that a highly efficient separation could save time, cost, and labor for laboratory operators. A numerical technique is demonstrated in this work to design a highly efficient microfluidic chip that can separate 64% plasma from blood with 100% purity. Simulations are carried out for the blood flow by a hybrid method of smoothed dissipative particle dynamics and immersed boundary method (SDPD-IBM). SDPD is used to model the motion of blood flow, while IBM is used to handle the interaction between cells and plasma. A single bifurcation, as the elementary component of the microfluidic chip, is first examined to find an optimal parameter group of flow rate and branch angle, which can generate a maximum separation efficiency on the premise of 100% purity. Then, the microfluidic chip is designed based on the optimal parameter group and compared with the existing experimental chip to analyze its performance. It is shown that the designed chip has a separation efficiency about 40% larger than the experimental one. Finally, the performance of the designed chip is analyzed by investigating the parameter dependence, and two critical parameters are studied, the cell hematocrit and inflow rate. The results provide an optimal hematocrit of 10.4% and an optimal inflow rate of 13.3 μl/h in order to obtain a high efficiency and 100% purity, which provides guidance for the level of diluting blood and the speed of injecting blood in experiments.
21 October 2020 in Physical Review E
Numerically reproducing the process of thrombus formation is highly desired for understanding its mechanism but still remains challenging due to the polydisperse feature of blood components and their multiple biochemical or biomechanical behaviors involved. We numerically implemented a simplified version of the process from the perspective of biomechanics, using a mesoscale particle-based method, smoothed dissipative particle dynamics-immersed boundary method. This version covers the adhesion and aggregation of platelets (PLTs), the deformation and aggregation of red blood cells (RBCs), and the interaction between PLTs and RBCs, as well as the blockage of microvessels. Four critical factors that can affect thrombus formation were investigated: the velocity of blood flow, the adhesive ability of PLTs, the interaction strength between PLTs and RBCs, and the deformability of RBCs. Increasing the velocity of blood flow was found to be the most effective way to reduce the microvessel blockage, and reducing the adhesive ability of PLTs is also a direct and efficient way. However, decreasing the interaction strength between PLTs and RBCs sometimes does not alleviate thrombus formation, and similarly, increasing the deformability of RBCs does not have a significant improvement for the severely blocked microvessel. These results imply that maintaining high-rate blood flow plays a crucial role in the prevention and treatment of thrombosis, which is even more effective than antiplatelet or anticoagulant drugs. The drugs or treatments concentrating on reducing the PLT-RBC interaction or softening the RBCs may not have a significant effect on the thrombosis.
1 February 2023 in Physics of Fluids
Hematocrit, defined as the volume percentage of red blood cells in blood, is an important indicator of human health status, which demonstrates the capability of blood to deliver oxygen. It has been studied over many decades using in vivo, in vitro, and in silico experiments, and recent studies have shown that its major feature in microvascular networks is the temporal-spatial heterogeneity. The present work is a numerical study of such temporal-spatial heterogeneity, based on direct simulations of cellular-scale blood flow in complex microvascular networks. The simulations take into account the cell deformation and aggregation and thus are able to capture both the three-dimensional dynamics of each individual cell and the temporal-spatial distribution of cell population. The results showed that the temporal-spatial heterogeneity is more pronounced in the network that has the vessels with smaller diameters or with more complex geometry. Such heterogeneity is largely attributed to the existence of bifurcations, where the positively correlated hypotactic (feeding-branch) and paratactic (branch-branch) relations are generally observed in both the time-averaged hematocrit and temporal hematocrit ranges. This suggests that the successive bifurcations have a substantial impact on the temporal-spatial heterogeneity of hematocrit. However, these positive correlations may be broken up if the diameter of the feeding vessel is small enough or the bifurcation is asymmetric extremely, due to the vessel blockage. The present study is of great clinical significance to help doctors make more accurate diagnosis and treatment, by providing more information about the temporal-spatial distribution of the hematocrit in microvascular networks.
1 December 2022 in AIP Advances
During hematogenous metastasis, the arrest of tumor cells in the microvasculature is a prerequisite for extravasation from the circulation to a distant host organ. To reveal such arrest behavior, we implement three-dimensional numerical simulations on the motion of a single tumor cell in microvessels at the cellular scale and mainly investigate the interactions among mechanical entrapment, adhesion, and cell stiffness, and their effects on the tumor cell arrest. Two types of vascular configurations qualifying for mechanical entrapment are considered, the constriction and bifurcation structures that are comparable in diameter with the tumor cell. The main results indicate that in the constriction tube, as the constriction radius is increased, the tendency that number of adhesion bonds increases with increasing shear modulus becomes more and more obvious. However, the adhesion behavior has little effect on the tumor cell arrest in the constriction region, regardless of the number of adhesion bonds. The mechanical entrapment plays a more important role than the cell stiffness in the tumor cell arrest in the constriction tube. In the bifurcated tube, the tumor cell is more likely to be arrested in the bifurcation region with a small bifurcation angle. Moreover, as the bifurcation angle or shear modulus is decreased, the effect of adhesion behavior on the tumor cell arrest becomes increasingly obvious. These results are helpful in understanding the biomechanism of tumor metastasis.