Wenjie Chen

Wenjie Chen

Auto-generated profile, based on publicly available information

Wenjie Chen

School of Mechanical and Aerospace Engineering, Nanyang Technological University, Nanyang Ave, Singapore

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2023 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
WCWenjie Chen
Wenjie Chen
KTKang Tai
Kang Tai
MLMichael Lau
Michael Lau
Ahmed AbdelhakimAhmed Abdelhakim
Ahmed Abdelhakim
RCRicky R. Chan
Ricky R. Chan
TTTegoeh Tjahjowidodo
Tegoeh Tjahjowidodo
The all-electric ship (AES) with DC-grid configuration has demonstrated advantages compared to the traditional AC system and has become the state-of-the-art for ships with electric propulsion in the low to medium power range during the past decade. However, the integration with different power sources, such as fuel cells, batteries and diesel gen-sets, increases the system complexity and requires an advanced power management system (PMS) to handle vessel operation and to achieve optimal power control. This paper presents an optimized power management strategy to reduce the total cost of ownership of such vessels, considering not only the fuel cost and emission penalty, but also the power device degradation and equipment replacement cost. In this study, Model Predictive Control (MPC) and Reinforcement Learning (RL)-based PMS control methods are approached respectively. In order to demonstrate the performance of MPC and RL techniques, a typical tugboat load profile is simulated. The testing results are also compared with a traditional rule-based power management control.

31 December 2021 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
WCWenjie Chen
Wenjie Chen
KTKang Tai
Kang Tai
MLMichael Lau
Michael Lau
Ahmed AbdelhakimAhmed Abdelhakim
Ahmed Abdelhakim
RCRicky R. Chan
Ricky R. Chan
TTTegoeh Tjahjowidodo
Tegoeh Tjahjowidodo
Environmentally driven regulations are significantly affecting shipping in recent years, where the shipbuilding industry is required to comply with upcoming restrictions concerning polluting emissions. The all-electric ship (AES) is one of the most promising technologies for complying with the increasingly strict environmental regulations, improving fuel efficiency, and enhancing system dynamic performance. In this study, the dc-distributed power grid of an AES integrated with fuel cells and batteries has been configured using extensive electrification technology, where the system-level shipboard power plant has been modeled with the average modeling method. The model not only incorporates the hybrid power source integration but also the primary and secondary power management as a whole. In addition, a hardware-in-the-loop (HIL) has been set up to replicate the real-time system behavior, which is essential for the verification of any optimal power management control algorithms to be developed in future work. Finally, both the mathematical and real-time models are validated against the full-scale hybrid shipboard power system.

4 October 2023 in IEEE Access
Verified
Journal Article
Open access
WCWenjie Chen
Wenjie Chen
KTKang Tai
Kang Tai
MLMichael Lau
Michael Lau
AAAhmed Abdelhakim
Ahmed Abdelhakim
RCRicky R. Chan
Ricky R. Chan
TTTegoeh Tjahjowidodo
Tegoeh Tjahjowidodo
The electrified hybrid shipboard power system with high-level integration of renewable energy resources and energy storage system has become the new trend for the all-electric ship (AES) configuration. However, the traditional energy management system (EMS) is not able to fulfill the increasingly complex control requirements, and a more advanced EMS control algorithm is required to handle the multiple power sources and even achieve optimal energy management control. This paper proposes supervisory energy management with an improved adaptive model predictive control (AMPC) strategy to optimize the power split of the hybrid power sources and to reduce the total cost of ownership (TCO) of vessel operation, which considers not only the fuel and emission cost but also the power source degradation. In order to achieve real-time implementation, the AMPC-based EMS software has been developed and deployed to a programmable logic controller (PLC) hardware.Ahybrid fuel cell-fed shipboard power system with a DC-grid configuration is modeled and operated on a hardware-in-the-loop (HIL) setup. The prototyping controller verification tests have been performed with this HIL plant in the lab environment. Three typical tugboat load profiles with power fluctuations are implemented as case studies. Lastly, a cost study was carried for a ten-year long-term vessel operational cycle. The proposed AMPC-based EMS can achieve up to 12.19% TCO savings compared to those of a traditional rule-based control strategy.

18 October 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
NSNastaran Shakeri
Nastaran Shakeri
WCWenjie Chen
Wenjie Chen
MZMehdi Zadeh
Mehdi Zadeh
Ahmed AbdelhakimAhmed Abdelhakim
Ahmed Abdelhakim
ASAsgeir J. Sørensen
Asgeir J. Sørensen
KTKang Tai
Kang Tai
This article proposes a framework for stability analysis of hydrogen fuel cell-based hybrid power systems (HPS) for zero-emission propulsion. An analytical model is developed and a comprehensive modal analysis is performed to address the HPS dynamic interactions. Sensitivity analysis assesses the impact of operating conditions, control parameters of the governor and converter controllers, and different control strategies. The case studies focus on how the parameters of the HPS state variables are coupled with the HPS modes through participation factors (PFs), thereby emphasizing which system state participates in determining the system’s dynamics. The modal analysis characterizes the influence of control parameters on poorly damped modes, and enables expanding the stable operating region of the HPS by appropriate control parameter selection. The results indicate a notable impact of the voltage control loop parameters on the system stability, a strong coupling between the subsystems’ current state variables and dc bus voltage dynamics, and a strong coupling between the governor dynamics and the FC current state. Additionally, the study demonstrates a PF of 0.9 between the dc bus voltage and the HPS’s critical modes within 15% deviation by changes in the voltage controller’s proportional gain. Finally, analytical analysis and time-domain simulations are validated with a real-time hardware-in-the-loop (HIL) test setup.