1 April 2019 in World Neurosurgery
16 August 2018 in BMC Musculoskeletal Disorders
Lumbar intervertebral disc herniation is a common cause of lower back and leg pain, with surgical intervention (e.g. discectomy to remove the herniated disc) recommended after an appropriate period of conservative management, however the existing or increased breach of the annulus fibrosus persists with the potential of reherniation. Several prosthesis and techniques to reduce re-herniation have been proposed including implantation of an annular closure device (ACD) – Barricaid™ and an annular tissue repair system (AR) – Anulex-Xclose™. The aim of this meta-analysis is to assist surgeons determine a potential approach to reduce incidences of recurrent lumbar disc herniation and assess the current devices regarding their outcomes and complications. Four electronic full-text databases were systematically searched through September 2017. Data including outcomes of annular closure device/annular repair were extracted. All results were pooled utilising meta-analysis with weighted mean difference and odds ratio as summary statistics. Four studies met inclusion criteria. Three studies reported the use of Barricaid (ACD) while one study reported the use of Anulex (AR). A total of 24 symptomatic reherniation were reported among 811 discectomies with ACD/AR as compared to 51 out of 645 in the control group (OR: 0.34; 95% CI: 0.20,0.56; I2 = 0%; P < 0.0001). Durotomies were lower among the ACD/AR patients with only 3 reported cases compared to 7 in the control group (OR: 0.54; 95% CI: 0.13, 2.23; I2 = 11%; P = 0.39). Similar outcomes for post-operative Oswestry Disability Index and visual analogue scale were obtained when both groups were compared. Early results showed the use of Barricaid and Anulex devices are beneficial for short term outcomes demonstrating reduction in symptomatic disc reherniation with low post-operative complication rates. Long-term studies are required to further investigate the efficacy of such devices.
1 December 2018 in Journal of Spine Surgery
Age-related degenerative changes and non-spondylotic pathologies of the cervical spine such as trauma and tumor can lead to compression of neurological structures and result in substantial alteration of the structural anatomy. The end-goal of surgical intervention is to decompress the neural structures which can be achieved via an anterior or a posterior approach, and stabilization of segments to restore stability and alignment. Three-dimensional printing (3DP or Additive Manufacturing) has been applied to the field of medicine, in particular orthopedics and neurosurgery. Coupled with advances of medical imaging such as computed tomography (CT) scans and magnetic resonance imaging (MRI), accurate 3D models of patient anatomy can be produced, and patient-specific implants (PSIs) for complex anatomical reconstruction have all been applied with positive outcomes. 3D printed implants have been applied in particular to the cervical spine predominantly due to the complex and relatively small osteological anatomy and the proximity of important neurovascular structures to the surgical sites. The purpose of this review is to evaluate the current application of 3DP for cervical spinal implants. This includes a review on the available literature on 3D printed PSIs and current available 3D printed “off-the-shelf” (OTS) implants (3D-OTS). Suitable materials for 3DP of spinal implants and the future prospect of cervical implants will be discussed. The review will be concluded with a suggested guide for carrying future studies to evaluate the efficacy and safety of 3DP for cervical spinal implants.
15 June 2019 in BMC Musculoskeletal Disorders
The purpose of this systematic review was to evaluate the accuracy and reliability of wearable devices for objective gait measurement of Lumbar Spinal Stenosis (LSS) patients, with a focus on relevant gait metrics. Systematic searches were conducted of five electronic databases to identify studies that assessed gait metrics by wearable or portable technology. Data was collected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Four articles were identified for inclusion in this review. The objectives, methodology and quality of the studies varied. No single gait metric was investigated in all four studies, making comparison difficult. The most relevant metrics reported included gait cycle, gait velocity, step length and cadence, which were reported in two studies. Two studies explored gait symmetry. Differences between LSS patients and normal healthy subjects are demonstrable using wearable technology. The measurements of gait cycle, cadence, step length, gait velocity, and number of steps with wearable devices can be used in the gait measurement of LSS patients for initial assessment, and objective outcomes following interventions. However, data and analysis are limited, and further studies are necessary to comment on reliability.
1 October 2020 in World Neurosurgery
1 December 2018 in World Neurosurgery