Oliver Beuing

Oliver Beuing

Auto-generated profile, based on publicly available information

Oliver Beuing

Department of Neuroradiology, Otto-von-Guericke University, Magdeburg, Germany

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
PBPhilipp Berg
Philipp Berg
DSDaniel Stucht
Daniel Stucht
GJGabor Janiga
Gabor Janiga
OBOliver Beuing
Oliver Beuing
OSOliver Speck
Oliver Speck
DTDominique Thévenin
Dominique Thévenin
Computational fluid dynamics (CFD) opens up multiple opportunities to investigate the hemodynamics of the human vascular system. However, due to numerous assumptions the acceptance of CFD among physicians is still limited in practice and validation through comparison is mandatory. Time-dependent quantitative phase-contrast magnetic resonance imaging PC-MRI measurements in a healthy volunteer and two intracranial aneurysms were carried out at 3 and 7 Tesla. Based on the acquired images, three-dimensional (3D) models of the aneurysms were reconstructed and used for the numerical simulations. Flow information from the MR measurements were applied as boundary conditions. The four-dimensional (4D) velocity fields obtained by CFD and MRI were qualitatively as well as quantitatively compared including cut planes and vector analyses. For all cases a high similarity of the velocity patterns was observed. Additionally, the quantitative analysis revealed a good agreement between CFD and MRI. Deviations were caused by minor differences between the reconstructed vessel models and the actual lumen. The comparisons between diastole and systole indicate that relative differences between MRI and CFD are intensified with increasing velocity. The findings of this study lead to the conclusion that CFD and MRI agree well in predicting intracranial velocities when realistic geometries and boundary conditions are provided. Due to the considerably higher temporal and spatial resolution of CFD compared to MRI, complex flow patterns can be further investigated in order to evaluate their role with respect to aneurysm formation or rupture. Nevertheless, special care is required regarding the vessel reconstruction since the geometry has a major impact on the subsequent numerical results.

1 July 2011 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
SSSanthosh Seshadhri
Santhosh Seshadhri
GJGabor Janiga
Gabor Janiga
OBOliver Beuing
Oliver Beuing
MSMartin Skalej
Martin Skalej
DTDominique Thévenin
Dominique Thévenin
Cerebral aneurysms constitute a major medical challenge as treatment options are limited and often associated with high risks. Statistically, up to 3% of patients with a brain aneurysm may suffer from bleeding for each year of life. Eight percent of all strokes are caused by ruptured aneurysms. In order to prevent this rupture, endovascular stenting using so called flow diverters is increasingly being regarded as an alternative to the established coil occlusion method in minimally invasive treatment. Covering the neck of an aneurysm with a flow diverter has the potential to alter the hemodynamics in such a way as to induce thrombosis within the aneurysm sac, stopping its further growth, preventing its rupture and possibly leading to complete resorption. In the present study the influence of different flow diverters is quantified considering idealized patient configurations, with a spherical sidewall aneurysm placed on either a straight or a curved parent vessel. All important hemodynamic parameters (exchange flow rate, velocity, and wall shear stress) are determined in a quantitative and accurate manner using computational fluid dynamics when varying the key geometrical properties of the aneurysm. All simulations are carried out using an incompressible, Newtonian fluid with steady conditions. As a whole, 72 different cases have been considered in this systematic study. In this manner, it becomes possible to compare the efficiency of different stents and flow diverters as a function of wire density and thickness. The results show that the intra-aneurysmal flow velocity, wall shear stress, mean velocity, and vortex topology can be considerably modified thanks to insertion of a suitable implant. Intra-aneurysmal residence time is found to increase rapidly with decreasing stent porosity. Of the three different implants considered in this study, the one with the highest wire density shows the highest increase of intra-aneurysmal residence time for both the straight and the curved parent vessels. The best hemodynamic modifications are always obtained for a small aneurysm diameter.

1 November 2015 in Journal of Biomechanics
Verified
Journal Article
Closed access
GJGabor Janiga
Gabor Janiga
LDLászló Daróczy
László Daróczy
PBPhilipp Berg
Philipp Berg
DTDominique Thévenin
Dominique Thévenin
MSMartin Skalej
Martin Skalej
OBOliver Beuing
Oliver Beuing

1 March 2022 in Stroke
Verified
Journal Article
Open access
PDF file
OZOsama O. Zaidat
Osama O. Zaidat
JFJohanna T. Fifi
Johanna T. Fifi
ANAshish Nanda
Ashish Nanda
BABenjamin Atchie
Benjamin Atchie
KWKeith Woodward
Keith Woodward
AHAmeer E. Hassan
Ameer E. Hassan
Background and Purpose: The purpose of the COMPLETE (International Acute Ischemic Stroke Registry With the Penumbra System Aspiration Including the 3D Revascularization Device) registry was to evaluate the generalizability of the safety and efficacy of the Penumbra System (Penumbra, Inc, Alameda) in a real-world setting. Methods: COMPLETE was a global, prospective, postmarket, multicenter registry. Patients with large vessel occlusion–acute ischemic stroke who underwent mechanical thrombectomy using the Penumbra System with or without the 3D Revascularization Device as frontline approach were enrolled at 42 centers (29 United States, 13 Europe) from July 2018 to October 2019. Primary efficacy end points were successful postprocedure angiographic revascularization (modified Thrombolysis in Cerebral Infarction ≥2b) and 90-day functional outcome (modified Rankin Scale score 0–2). The primary safety end point was 90-day all-cause mortality. An imaging core lab determined modified Thrombolysis in Cerebral Infarction scores, Alberta Stroke Program Early CT Scores, clot location, and occurrence of intracranial hemorrhage at 24 hours. Independent medical reviewers adjudicated safety end points. Results: Six hundred fifty patients were enrolled (median age 70 years, 54.0% female, 49.2% given intravenous recombinant tissue-type plasminogen activator before thrombectomy). Rate of modified Thrombolysis in Cerebral Infarction 2b to 3 postprocedure was 87.8% (95% CI, 85.3%–90.4%). First pass and postprocedure rates of modified Thrombolysis in Cerebral Infarction 2c to 3 were 41.5% and 66.2%, respectively. At 90 days, 55.8% (95% CI, 51.9%–59.7%) had modified Rankin Scale score 0 to 2, and all-cause mortality was 15.5% (95% CI, 12.8%–18.3%). Conclusions: Using Penumbra System for frontline mechanical thrombectomy treatment of patients with large vessel occlusion–acute ischemic stroke in a real-world setting was associated with angiographic, clinical, and safety outcomes that were comparable to prior randomized clinical trials with stringent site and operator selection criteria. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03464565.

1 October 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
LSLisa Schneider
Lisa Schneider
ANAnnika Niemann
Annika Niemann
OBOliver Beuing
Oliver Beuing
BPBernhard Preim
Bernhard Preim
SSSylvia Saalfeld
Sylvia Saalfeld

10 January 2018 in European Journal of Human Genetics
Verified
Journal Article
Open access
PDF file
RAReza Asadollahi
Reza Asadollahi
JSJustin E Strauss
Justin E Strauss
MZMartin Zenker
Martin Zenker
OBOliver Beuing
Oliver Beuing
SESimon Edvardson
Simon Edvardson
ARAnita Rauch
Anita Rauch
Acrocallosal syndrome (ACLS) is an autosomal recessive neurodevelopmental disorder caused by KIF7 defects and belongs to the heterogeneous group of ciliopathies related to Joubert syndrome (JBTS). While ACLS is characterized by macrocephaly, prominent forehead, depressed nasal bridge, and hypertelorism, facial dysmorphism has not been emphasized in JBTS cohorts with molecular diagnosis. To evaluate the specificity and etiology of ACLS craniofacial features, we performed whole exome or targeted Sanger sequencing in patients with the aforementioned overlapping craniofacial appearance but variable additional ciliopathy features followed by functional studies. We found (likely) pathogenic variants of KIF7 in 5 out of 9 families, including the original ACLS patients, and delineated 1000 to 4000-year-old Swiss founder alleles. Three of the remaining families had (likely) pathogenic variants in the JBTS gene C5orf42, and one patient had a novel de novo frameshift variant in SHH known to cause autosomal dominant holoprosencephaly. In accordance with the patients’ craniofacial anomalies, we showed facial midline widening after silencing of C5orf42 in chicken embryos. We further supported the link between KIF7, SHH, and C5orf42 by demonstrating abnormal primary cilia and diminished response to a SHH agonist in fibroblasts of C5orf42-mutated patients, as well as axonal pathfinding errors in C5orf42-silenced chicken embryos similar to those observed after perturbation of Shh signaling. Our findings, therefore, suggest that beside the neurodevelopmental features, macrocephaly and facial widening are likely more general signs of disturbed SHH signaling. Nevertheless, long-term follow-up revealed that C5orf42-mutated patients showed catch-up development and fainting of facial features contrary to KIF7-mutated patients.