24 November 2017 in Earthquake Engineering & Structural Dynamics
3 November 2018 in Journal of Intelligent Material Systems and Structures
Base isolation system is widely used to protect important and essential buildings from seismic hazards. The use of high damping is effective in reducing the resonance effect under long-period earthquake ground motions. However, high damping increases the acceleration demand under short-period ground motions, leading to a higher risk of damage of nonstructural components. Actually, low damping is beneficial to reduce the acceleration demand under short-period ground motions, suggesting the use of adaptive damping control, that is, high damping under long-period motions and low damping under short-period motions. In order to implement this concept, a semi-actively controlled base isolation system is provided in this article along with a new control law based on the transmissibility theory. Unlike existing studies, the proposed method enables a systematic design procedure for base isolated structures with semi-active dampers, which is called the simplified design procedure in this article. The performance of the proposed system is evaluated with numerical simulations for a base isolated three-story building with magneto-rheological dampers. It was shown that the proposed system achieves a high level of performance under long-period ground motions, while maintaining the exceptional performance of a conventional base isolation system with low damping under short-period ground motions.
15 April 2018 in Earthquake Engineering & Structural Dynamics
27 April 2023 in Earthquake Engineering & Structural Dynamics
11 January 2024 in Earthquake Engineering & Structural Dynamics
8 February 2022 in Journal of Intelligent Material Systems and Structures
The transmissibility-based semi-active (TSA) controller was developed in the existing study by the authors, which can effectively enhance the performance of base-isolated buildings under both strong long- and short-period earthquake ground motions. Since the performance of the TSA controller was only evaluated with numerical simulation in the existing study, this paper further validates its performance experimentally by conducting real-time hybrid simulation (RTHS). A three-story base isolated building was designed based on a simplified design procedure, where the base isolation system of the building consisted of three different devices, that is, a magneto-rheological (MR) damper, rubber bearing, and linear bearings. The base isolation system was experimentally tested with the MR damper controlled by the TSA controller, and the building superstructure was analytically modeled. It was shown that the TSA controller makes the system damping high under long-period ground motions and low under short-period ground motions, which performed uniquely as intended. As a result, the isolator displacement was effectively reduced under long-period ground motions, while the story drift and acceleration responses were also reduced under short-period ground motions, all of which are difficult to achieve at the same time using passive damping only.