This paper presents a chipless radio frequency identification (RFID) sensor tag having both identification and sensing capabilities. It is based on one resonant scatterer operating as a signal processing antenna in the 3-7.5 GHz band. The scatterer is used to monitor a physical parameter variation, as well as to identify the remote sensor. To make a resonator sensitive to the humidity, silicon nanowires are deposited on the tag surface using a simple process. The tag needs only one conductive layer so that it can be directly printed on the product to sense and to identify. Measurements done using a bistatic radar configuration in the frequency domain validate this concept. To demonstrate the reliability of such an application, two chipless RFID sensors placed in various environments are simultaneously detected using an anticollision technique based on spectral separation.
This article reports the first results of a Nafion®-based, solid state, non-volatile, electronically reconfigurable Radio Frequency (RF)-switch integrated to a co-planar waveguide transmission line (CPW) in shunt mode, on a flexible paper substrate. The switch is based on a metal–insulator–metal structure formed respectively using Silver–Nafion–aluminum switching layers. The presented device is fully passive and shows good performance till 3 GHz, with an insertion loss less than 3 dB in the RF-on state and isolation greater than 15 dB in the RF-off state. Low-power direct current pulses in the range 10 V/0.5 mA and −20 V/0.15 A are used to operate the switch. The device was fabricated in an ambient laboratory condition, without the use of any clean room facilities. A brief discussion of the results and potential application of this concept in a re-configurable chipless RFID tag is also given in this article. This study is a proof of concept of fabrication of electronically re-configurable and disposable RF-electronic switches on low cost and flexible substrates, using a process feasible for mass production.
In this letter, we demonstrate the possibility to design a compact and ultralow power wireless node for environment sensing operating in the UHF band at 868 MHz. The wireless device is based on an ultralow power 8 b microcontroller associated with a digital temperature and relative humidity sensor. It communicates according to the backscattering principle to a software-defined radio (SDR) controlled by a graphical user interface developed in GNU Radio. The wireless node features a power consumption of 5 μA under 1.8 V, which is good enough for communicating data with a packet error rate of 10% at 110 b/s over a range of 30 m in an indoor environment for a transmitting power of 20 dBm. The design of the wireless node and its SDR-based detection system is validated with wireless measurements both in an anechoic chamber and in the indoor environment.
19 July 2023 in IEEE Journal of Radio Frequency Identification
This paper presents a novel long-term electronic implant enabled by passive UHF RFID technology to detect early signs of loosening between orthopedic knee prostheses and bones. It is composed of an AMS SL900A chip, connected to a miniaturized antenna matched to a bio-tissue environment. The implant embeds an external capacitive membrane sensor to detect force variation correlated with a loss of adhesion between the tibia component of the total knee prosthesis and the prosthesis. This stainless steel membrane sensor features high endurance and can detect the first signs of loosening from an applied compression force of 1.25 N. It corresponds to a measured capacitance change of 10fF. The overall size of the RFID implant inserted in the tibial tray is 12.65mm x 12.3mm with a thickness of 2.63 mm, including the casing. Both simulations and practical measurements validate this novel work for various simulated bio-tissue environments in the presence of metal. Besides, a theoretical study on SAR exposure confirms the compatibility with regulatory constraints. Finally, a test bench composed of a force bench, an external RFID reader, and the RFID implant inserted within the tibial component of a knee prosthesis provides proof of concept for the proposed system.
In this paper, a simple solution allowing continuous actimetry with an uniaxial magnetometer is presented. Worn on the wrist to monitor the forearm tilt, it can estimate the instantaneous metabolic-equivalent-of-task during physical activity. Autonomous acquisition and data transfer are managed by a radio frequency identification chip supporting the near field communication (NFC) standard. Thus, the solution can transfer measurements to an NFC-enabled device (computer and smartphone) that runs a custom algorithm. The algorithm output signal was indirectly calibrated to an accurate calorimetry device to display the real energy expenditure of the user during the physical activity session.
Pressure sensors are essential across a wide range of application domains, each requiring tailored performance characteristics. In this work, we propose a novel passive and wireless pressure sensor featuring a compact sandwich structure composed of a metasurface (MTS) layer, a compressible Polydimethylsiloxane (PDMS) substrate, and a metallic ground plane. When pressure is applied, the PDMS layer undergoes mechanical deformation, leading to both a reduction in thickness and an increase in relative permittivity, which in turn causes a measurable shift in the resonance frequency. A detailed theoretical model based on a pressure-dependent Debye formulation is presented to describe the influence of mechanical compression on the electromagnetic response. The model is validated through full-wave simulations and experimental results. The sensor operates around 22 GHz and can be interrogated wirelessly from a distance of up to 25 cm. It is capable of measuring pressures up to 55 kPa, maintaining stable performance across multiple loading cycles. Thanks to its battery-free operation, compact size, and ease of fabrication, the proposed sensor is well-suited for remote pressure monitoring in environments where conventional wired or active sensors may not be viable.