Nethra Venkatayogi

Nethra Venkatayogi

Auto-generated profile, based on publicly available information

Nethra Venkatayogi

Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
ASAshikuzzaman
Ashikuzzaman
ASArunima Sharma
Arunima Sharma
NVNethra Venkatayogi
Nethra Venkatayogi
EOEniola Oluyemi
Eniola Oluyemi
KMKelly Myers
Kelly Myers
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
Energy-based displacement tracking of ultrasound images can be implemented by optimizing a cost function consisting of a data term, a mechanical congruency term, and first- and second-order continuity terms. This approach recently provided a promising solution to two-dimensional axial and lateral displacement tracking in ultrasound strain elastography. However, the associated second-order regularizer only considers the unmixed second derivatives and disregards the mixed derivatives, thereby providing suboptimal noise suppression and limiting possibilities for total strain tensor imaging. We propose to improve axial, lateral, axial shear, and lateral shear strain estimation quality by formulating and optimizing a novel L 1-norm-based second-order regularizer that penalizes both mixed and unmixed displacement derivatives. We name the proposed technique L 1-MixTURE, which stands for L 1-norm Mixed derivative for Total UltRasound Elastography. When compared to simulated ground truth results, the mean structural similarity (MSSIM) obtained with L 1-MixTURE ranged 0.53 to 0.86 and the mean absolute error (MAE) ranged 0.00053 to 0.005. In addition, the mean elastographic signal-to-noise ratio (SNR) achieved with simulated, experimental phantom, and in vivo breast datasets, ranged 1.87 to 52.98, and the mean elastographic contrast-to-noise ratio (CNR) ranged 7.40 to 24.53. When compared to a closely related existing technique that does not consider the mixed derivatives, L 1-MixTURE generally outperformed the MSSIM, MAE, SNR, and CNR by up to 37.96%, 67.82%, and 25.53% in the simulated, experimental phantom, and in vivo datasets, respectively. These results collectively highlight the ability of L 1-MixTURE to deliver highly accurate axial, lateral, axial shear, and lateral shear strain estimates and advance the state-of-the-art in elastography-guided diagnostic and interventional decisions.

1 January 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
MGMardava R. Gubbi
Mardava R. Gubbi
AKAravindan Kolandaivelu
Aravindan Kolandaivelu
NVNethra Venkatayogi
Nethra Venkatayogi
JZJiaxin Zhang
Jiaxin Zhang
PWPankaj Warbal
Pankaj Warbal
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
Objective: To develop the first known deep learning-based photoacoustic visual servoing system utilizing point source localization and hybrid position-force control to track catheter tips in three dimensions in real-time. Methods: We integrated either object detection or instance segmentation-based localization with hybrid position-force control to create our novel system. Cardiac catheter tips were then tracked across distances of 40 mm in a plastisol phantom and 25-64 mm in an in vivo swine in real-time in nine visual servoing trials total. Results: Object detection-based localization identified the cardiac catheter tip in 88.0-91.7% and 66.7-70.4% of phantom and in vivo channel data frames, respectively. Instance segmentation detection rates ranged 86.4-100.0% in vivo. These catheter tips were tracked with errors as low as 0.5 mm in phantom trials and 0.8 mm in the in vivo trials. The mean inference times were ≥145.3 ms and ≥516.3 ms with object detection-based and instance segmentation-based point source localization, respectively. Hybrid position-force control system enabled contact with the imaging surface during ≥99.43% of each visual servoing trial. Conclusion: Our novel deep learning-based photoacoustic visual servoing system was successfully demonstrated. Object detectionbased localization operated with inference times that are more suitable for real-time implementations while instance segmentation had lower tracking errors. Significance: After implementing suggested optimization modifications, our novel system has the potential to track catheter tips, needle tips, and other surgical tool tips in real-time during surgical and interventional procedures.

11 March 2025 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
NVNethra Venkatayogi
Nethra Venkatayogi
ASArunima Sharma
Arunima Sharma
EAEmily B. Ambinder
Emily B. Ambinder
KMKelly S. Myers
Kelly S. Myers
EOEniola T. Oluyemi
Eniola T. Oluyemi
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
To perform the first known investigation of differences between real-time and offline B-mode and short-lag spatial coherence (SLSC) images when evaluating fluid or solid content in 60 hypoechoic breast masses. Real-time and retrospective (i.e., offline) reader studies were conducted with three board-certified breast radiologists, followed by objective, reader-independent discrimination using generalized contrast-to-noise ratio (gCNR). The content of 12 fluid, solid and mixed (i.e., containing fluid and solid components) masses were uncertain when reading real-time B-mode images. With real-time and offline SLSC images, 15 and 5, respectively, aggregated solid and mixed masses (and no fluid masses) were uncertain. Therefore, with real-time SLSC imaging, uncertainty about solid masses increased relative to offline SLSC imaging, while uncertainty about fluid masses decreased relative to real-time B-mode imaging. When assessing real-time SLSC reader results, 100% (11/11) of solid masses with uncertain content were correctly classified with a gCNR<0.73 threshold applied to real-time SLSC images. The areas under receiver operator characteristic curves characterizing gCNR as an objective metric to discriminate complicated cysts from solid masses were 0.963 and 0.998 with real-time and offline SLSC images, respectively, which are both considered excellent for diagnostic testing. Results are promising to support real-time SLSC imaging and gCNR application to real-time SLSC images to enhance sensitivity and specificity, reduce reader variability, and mitigate uncertainty about fluid or solid content, particularly when distinguishing complicated cysts (which are benign) from hypoechoic solid masses (which could be cancerous).

24 October 2025 in Radiology Advances
Verified
Journal Article
Open access
ASArunima Sharma
Arunima Sharma
EOEniola T Oluyemi
Eniola T Oluyemi
MTMadhavi Tripathi
Madhavi Tripathi
EAEmily B Ambinder
Emily B Ambinder
LMLisa A Mullen
Lisa A Mullen
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
Background: Benefits of ultrasound in breast cancer detection are often limited by the similar appearance of complicated cysts and solid hypoechoic masses with B-mode imaging, which can lead to false positive diagnoses. Purpose: To evaluate the diagnostic performance of generalized contrast-to-noise ratio (gCNR) on short-lag spatial coherence (SLSC) ultrasound images as an objective tool to improve complicated cyst vs solid mass classification. Materials and Methods: For this secondary analysis of a prospective recruitment for the Advanced Ultrasound Signal Processing of Suspicious Breast Images (AUSPICIOUS) observational study (NCT07206888), women scheduled for ultrasound-guided procedures or follow-up of at least 1 breast mass were enrolled from March 2018 to October 2023. Raw ultrasound data were acquired with an Alpinion ECUBE12R research scanner, then post-processed with our custom software. The primary evaluation indicator was gCNR applied to SLSC images with regions of interest determined by 6 radiologists. Outcomes were compared to the same radiologists classifying mass contents as solid, fluid, mixed, or uncertain using B-mode images. The reference standard was determined by aspiration, pathology, or characterization of image features. Areas under receiver operating characteristic curves (AUCs) with 95% confidence intervals (CIs) and inter-reader agreement (Fleiss’ κ) were assessed. Results: Among 175 cases, 145 breast masses from 115 women (age: 52 ± 17 years) were analyzed, including 16 complicated cysts and 96 solid masses. The mean AUC for complicated cyst vs solid mass characterization was 0.96 (95% CI: 0.94, 0.97) with gCNR applied to SLSC images, relative to a mean lower-bound AUC of 0.67 (range: 0.54-0.76) with readings of B-mode images (P < .05). Inter-reader agreement improved from fair with B-mode (κ = 0.40) to moderate with gCNR applied to SLSC images with a 0.76 threshold (κ = 0.59, P < .00001). Conclusion: Applying an objective gCNR metric to SLSC images improved the differentiation of complicated cysts from solid masses when compared to subjective readings of B-mode images.

1 March 2026 in Journal of Biomedical Optics
Verified
Journal Article
Open access
JAJunior Arroyo
Junior Arroyo
JZJunhao Zhang
Junhao Zhang
JZJiaxin Zhang
Jiaxin Zhang
NVNethra Venkatayogi
Nethra Venkatayogi
MKManik Kakkar
Manik Kakkar
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
SignificanceUreteral injuries represent a major concern during a range of surgical procedures, due to the proximity of the ureter to target surgical structures. Intraoperative identification of the ureter is critical to prevent this accidental damage.AimWe demonstrate the first known in vivo photoacoustic imaging of the ureter in swine following intravenous administration of FDA-approved methylene blue, enabled by a software-hardware integration that has not been previously reported in the literature.ApproachPhotoacoustic channel data from the ureters of two swine were acquired using a Vevo F2 ultrasound system and an Opotek Phocus Mobile laser. Images were beamformed using a delay-and-sum algorithm. Photoacoustic image quality was evaluated using contrast, signal-to-noise ratio (SNR), and generalized contrast-to-noise ratio (gCNR) metrics, measured 10 to 80 min after methylene blue injection.ResultsAcross the 10- to 80-min imaging window, median contrast (3.46–11.43 dB), SNR (2.84–6.99), and gCNR (0.27–0.64) confirmed sustained ureter visibility with methylene blue. Maximum image quality was observed 20- to 30-min after methylene blue injection, with significantly higher contrast, SNR, and gCNR values compared with earlier or later time points (p<0.05).ConclusionsIn vivo results demonstrate that methylene-blue-enhanced photoacoustic imaging can visualize the ureter over a time duration that is consistent with the length of surgical procedures, providing initial feasibility for real-time photoacoustic-guided surgery applications.

23 May 2026 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
NVNethra Venkatayogi
Nethra Venkatayogi
KWKaren C. Wang
Karen C. Wang
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
Purpose: Photoacoustic imaging has the potential to provide real-time surgical guidance to avoid ureteral injury during hysterectomies, including photoacoustic-based distance measurements and auditory alerts to warn surgeons of unsafe proximity. Validation of tool tip tracking performance and assessments of surgeon interaction with multiple feedback options derived from photoacoustic-based tool tip tracking are essential to assess the expected impact. Methods: Tracked tool tip positions were compared with ground-truth data acquired to validate our recently proposed velocity-based tracking approach. A user study with gynecological surgeons, OB/GYN residents, and a control group of non-medical professionals was then performed to determine the extent of improvements that can be achieved with multiple photoacoustic-based feedback techniques derived from the proposed velocity-based tracking approach. Results: The average mean tracking errors across various programmed tool motions were 0.24 mm and 0.56 mm in the lateral and axial dimensions, respectively. Combinations of photoacoustic-based distance measurements, auditory feedback, and photoacoustic video display improved correct classifications of tool-to-ureter distances by 11.1% to 48.1% and reduced the aggregated response times among users by 1.72–2.15 s (i.e., 37–47% improvement) relative to camera videos. Conclusion: Results are promising for the continued development of a photoacoustic surgical guidance system that successfully mitigates ureteral injuries during hysterectomies, simultaneously enabling reduced reliance on subjective camera-based visualization and addressing limitations of depth perception in conventional surgical imaging. This integration of photoacoustic image guidance into intraoperative workflows has the potential to enhance surgical safety.