Jiahan Wang

Jiahan Wang

Auto-generated profile, based on publicly available information

Jiahan Wang

Haikou Marine Geological Survey Center, China Geological Survey, Haikou 571127, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2024 in RSC Advances
Verified
Journal Article
Open access
PDF file
WJWang Jiahan
Wang Jiahan
LXLiu Xiaowei
Liu Xiaowei
YFYang Feng
Yang Feng
YXYang Xiujiu
Yang Xiujiu
JWJinli Wang
Jinli Wang
CYChen Yan
Chen Yan
Microplastics, defined as small pieces of plastic with a size less than 5 millimeters, constitute a significant sink for microplastics in marine sediments. Given the potential harm to nature and human beings, accurate detection of microplastics in marine sediments is of the utmost importance. The separation of microplastics from marine sediments represents a pivotal step in the quantitative detection of microplastics. This paper presents a high-efficiency extraction device for microplastics in marine sediments, with the objective of enhancing the effectiveness and efficiency of microplastics extraction. The device employs an air pump to thoroughly mix the samples and incorporates metal perforated plate fillers to achieve efficient sedimentation, thus facilitating the separation of microplastics from the surrounding marine sediments. Subsequently, the separated microplastics are passed through a series of pore sizes of stainless steel screens and glass fibre filters via suction filtration, allowing for the collection of microplastics of varying particle sizes for subsequent identification. Following a series of method trials, the optimal extraction conditions for this device were identified. The results demonstrated its excellent extraction effectiveness and high efficiency. To verify the feasibility of this device, it was used to investigate the microplastics in the sediments of Dongzhai Harbor, Hainan. The abundance, particle size distribution, shape, and composition of microplastics in the sediments of this area were obtained, which not only validated the practicality of this microplastic extraction device but also provided significant insights for ecological and environmental protection in the region.

10 October 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JWJiahan Wang
Jiahan Wang
JLJunqiao Long
Junqiao Long
FYFeng Yang
Feng Yang
XYXiujin Yang
Xiujin Yang
JWJinli Wang
Jinli Wang
Cheng HuangCheng Huang
Cheng Huang
To overcome the corrosion of hydrofluoric acid on the ICP OES injection system in the acid dissolution system, this paper makes some improvements based on the traditional open digestion. The improved method does not require the complete removal of hydrofluoric acid. After appropriate digestion of the sample with a mixed acid, the solution can be transferred to a colorimetric tube containing ammonium hydroxide solution to give the final volume for analysis. In this paper, two-point standard curves are plotted using soil standards and process blanks, which is not only convenient but also overcomes the interference of the matrix effect. Through continuous experiments, the preferred ratio of mixed acid is 3 mL nitric acid + 5 mL hydrofluoric acid, and the concentration of ammonia solution is 0.5%. The spectral lines of the measured elements V (292.4), Cr (283.5), Co (228.6), Ni (231.6), Cu (324.7), Zn (213.8) and Pb (220.3) were determined. The method quantification limits of the seven measured elements V, Cr, Co, Ni, Cu, Zn and Pb were 0.909, 4.32, 0.269, 0.261, 0.968, 3.69 and 2.64 μg g-1, respectively, and the precision was 3.5%, 5.2%, 4.8%, 2.4%, 6.1% and 4.5%, respectively. After processing six national standard materials according to the experimental method, the measured values of each measured element were basically in agreement with the certified values, indicating that this method is fully feasible for the measurement of V, Cr, Co, Ni, Cu, Zn and Pb in soil. This method greatly improves the efficiency of pretreatment and is particularly suitable for analysing large batches of samples.