1 February 2024 in Review of Scientific Instruments
We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (⌀0.42 m) and large (⌀6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ∼50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad s. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.
8 April 2022 in Physical Review D
Recent measurements from the CMB and from high-redshift galaxy observations have placed rough constraints on the midpoint and duration of the epoch of reionization. Detailed measurements of the ionization history remain elusive, although two proposed probes show great promise for this purpose: the 21 cm global signal and the kinetic Sunyaev-Zel’dovich (kSZ) effect. We formally confirm the common assumption that these two probes are highly complementary, with the kSZ being more sensitive to extended ionization histories and the global signal to rapidly evolving ones. We do so by performing a Karhunen-Loève (KL) transformation, which casts the data in a basis designed to emphasize the information content of each probe. We find that reconstructing the ionization history using both probes gives significantly more precise results than individual constraints, although carefully chosen, physically motivated priors play a crucial part in obtaining a bias-free reconstruction. Additionally, in the KL basis, measurements from one probe can be used to detect the presence of residual systematics in the other, providing a safeguard against systematics that would go undetected when data from each probe is analyzed in isolation. Once detected, the modes contaminated by systematics can be discarded from the data analysis to avoid biases in reconstruction.
2 September 2025 in Physical Review D
DMRadio- m 3 is an experimental search for dark matter axions. It uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. DMRadio- m 3 is designed to be sensitive to Kim-Shifman-Vainshtein-Zakharov (KSVZ) and Dine-Fischler-Srednicki-Zhitnisky (DFSZ) QCD axion models in the 10–200 MHz ( 41 neV / c 2 – 0.83 μ eV / c 2 ) range, and to axions with g a γ γ = g a γ γ , DFSZ ( 30 MHz ) = 1.87 × 10 − 17 GeV − 1 over 5–30 MHz as an extended goal. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio- m 3 , which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of 2 larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a 3 σ live scan time of 2.9 years.
4 September 2025 in Journal of Applied Physics
We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m3 axion search, which uses dc SQUIDs in this frequency range.
16 April 2025 in Cryogenics
5 November 2026 in Physical Review D
Searches for QCD axions with masses in the n eV / c 2 mass range are strongly motivated by new physics at the grand unified theory (GUT) scale and by well-motivated preinflationary axion symmetry breaking scales. This parameter space is challenging to probe due to the small axion-photon couplings, which typically require large, high-field magnets with substantial stored energy. In this paper, we propose a new experimental geometry based on a narrow-bore, segmented solenoid that optimizes the collection of the axion-induced signal using LC resonators outside the high-field region of the magnet bore. This alternative optimization significantly reduces the required stored magnetic energy while preserving sensitivity, thus enabling a near-term experiment in the 30–200 MHz ( 120 − 830 n eV / c 2 ) range, with a cost-effective, staged scaling to a GUT-scale experiment in the 100 kHz–30 MHz ( 0.4 − 120 n eV / c 2 ) range.