Minsik Sung

Minsik Sung

Auto-generated profile, based on publicly available information

Minsik Sung

Departments of Mechanical Engineering, Electrical Engineering, Convergence IT Engineering, Medical Science and Engineering, Industrial and Management Engineering, and Medical Device and Innovation Center, Pohang University of Science and Technology, Pohang, Republic of Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2025 in Science Advances
Verified
Journal Article
Open access
SPSinyoung Park
Sinyoung Park
MSMinsik Sung
Minsik Sung
HKHyunhee Kim
Hyunhee Kim
KLKi Jong Lee
Ki Jong Lee
EPEun-Yeong Park
Eun-Yeong Park
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
Breast cancer screening with mammography is less effective in women with dense breast tissue, prompting the use of ultrasound (US) imaging. While two- (2D) and three-dimensional (3D) US improve cancer detection, their low specificity leads to frequent unnecessary biopsies. Operator dependence on 2D US has led to the development of 3D automated breast volume scanners (ABVS), but challenges remain in distinguishing benign from malignant lesions. We developed a 3D photoacoustic and ultrasound (PAUS)–ABVS system that integrates a large field-of-view, 768-element transducer to improve diagnostic accuracy. In a clinical study of 61 patients with 36 benign and 30 malignant lesions, multispectral photoacoustic imaging was used to measure blood volume and oxygen saturation within lesions. When combined with standard US BI-RADS (breast imaging reporting and data system) scores, the system achieved a sensitivity of 96.7% and specificity of 66.7%. This performance matched the best outcomes of 2D PAUS and outperformed conventional US. Our results suggest that the PAUS-ABVS can support more accurate breast cancer diagnosis while reducing unnecessary biopsies.

1 January 2024 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
DODonghyeon Oh
Donghyeon Oh
HKHyunhee Kim
Hyunhee Kim
MSMinsik Sung
Minsik Sung
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
SignificanceEndocavity ultrasound (US) imaging is a frequently employed diagnostic technique in gynecology and urology for the assessment of male and female genital diseases that present challenges for conventional transabdominal imaging. The integration of photoacoustic (PA) imaging with clinical US imaging has displayed promising outcomes in clinical research. Nonetheless, its application has been constrained due to size limitations, restricting it to spatially confined locations such as vaginal or rectal canals.AimThis study presents the development of a video-rate (20 Hz) endocavity PA/harmonic US imaging (EPAUSI) system.ApproachThe approach incorporates a commercially available endocavity US probe with a miniaturized laser delivery unit, comprised of a single large-core fiber and a line beamshaping engineered diffuser. The system facilitates real-time image display and subsequent processing, including angular energy density correction and spectral unmixing, in offline mode.ResultsThe spatial resolutions of the concurrently acquired PA and harmonic US images were measured at 318 μm and 291 μm in the radial direction, respectively, and 1.22 deg and 1.50 deg in the angular direction, respectively. Furthermore, the system demonstrated its capability in multispectral PA imaging by successfully distinguishing two clinical dyes in a tissue-mimicking phantom. Its rapid temporal resolution enabled the capture of kinetic dye perfusion into an ex vivo porcine ovary through the depth of porcine uterine tissue. EPAUSI proved its clinical viability by detecting pulsating hemodynamics in the male rat’s prostate in vivo and accurately classifying human blood vessels into arteries and veins based on sO2 measurements.ConclusionsOur proposed EPAUSI system holds the potential to unveil previously overlooked indicators of vascular alterations in genital cancers or endometriosis, addressing pressing requirements in the fields of gynecology and urology.

1 April 2026 in Stroke
Verified
Journal Article
Closed access
DJDongyoung Jeong
Dongyoung Jeong
JAJun Ho Ahn
Jun Ho Ahn
Wonseok ChoiWonseok Choi
Wonseok Choi
HLHan-Bin Lee
Han-Bin Lee
JKJoo Young Kweon
Joo Young Kweon
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
BACKGROUND: Despite antiplatelet therapy, plaque-induced strokes recur frequently. This recurrence may reflect thrombus heterogeneity driven by peri-stenotic stagnation and red blood cell (RBC) entrapment. The clinical implications of such variations for stroke outcomes remain unclear. We investigated whether plaque-derived RBC-rich thrombi, indicated by the clot sign, were associated with recurrence, lesion volume, and stenosis-related hemodynamics. METHODS: Because asymptomatic plaque rupture limits direct evaluation of hemodynamics and thrombus compositions, we performed a hybrid human-animal study. In humans, we conducted a retrospective case-control study across 2 tertiary stroke centers in the Republic of Korea between April 2017 and March 2024, evaluating stroke recurrence and lesion volume by clot sign, using inverse probability of treatment weighting. We included artery-to-artery embolization confirmed by diffusion weighted imaging, excluding other etiologies. In animals, thrombus compositions were histologically analyzed in an FeCl 3 -induced stenosis model across 3 segments (ascent, peak, and descent). Peri-stenotic hemodynamics, including wall shear stress and relative residence time, were assessed using ultrafast ultrasound imaging to evaluate whether RBC entrapment correlated with elevated relative residence time. RESULTS: In humans, clot sign-positive patients exhibited higher recurrence risk (hazard ratio, 2.76 [95% CI, 1.32–5.74]; P =0.007), and larger lesion (mean difference, 16.14 [95% CI, 5.03–27.25]; P =0.005). In animals, RBCs proportion was increased in the descent (ascent, 23.89±15.91%; peak, 12.33±11.19%; descent, 59.58±35.09%; P =0.019), correlating with a 3-fold higher relative residence time in the descent than the other regions (ascent, 1.25±0.75 au; peak, 1.55±0.55 au; descent, 4.50±2.74 au; P =0.001) CONCLUSIONS: Peri-stenotic stagnation was associated with RBC-rich thrombi formation under both clinical and experimental conditions, providing mechanistic insight into stroke recurrence and larger lesion volumes. Identifying peri-stenotic stagnation using ultrafast ultrasound imaging may help stratify high-risk patients; however, its therapeutic implications require validation in prospective randomized studies.


6 November 2026 in Science Advances
Verified
Journal Article
Open access
MSMinsik Sung
Minsik Sung
SNSunghun Nam
Sunghun Nam
SKSun Oh Kim
Sun Oh Kim
JPJong-Il Park
Jong-Il Park
DJDong Young Jeong
Dong Young Jeong
Chang-Seok KimChang-Seok Kim
Chang-Seok Kim
Assessing the risk of carotid plaque rupture remains limited because current imaging methods cannot provide both plaque composition and structural information in real time. Here, we present human carotid plaque risk imaging (hCAPRI), a multiparametric photoacoustic and ultrasound (PA/US) fusion method for real-time carotid plaque assessment. hCAPRI combines PA imaging for detecting intraplaque hemorrhage (IPH) with US imaging for evaluating the plaque structure. PA imaging measured IPH size and methemoglobin content, while US imaging assessed stenosis severity, calcification, and plaque thickness. Combining these PA/US parameters, we compute an hCAPRI score. In 171 carotid arteries (CAs) from 120 patients, hCAPRI revealed the relationships among the PA/US parameters. In 36 CAs validated with magnetic resonance imaging (MRI), hCAPRI showed high agreement with MRI. The hCAPRI score achieved 89% sensitivity and 84% specificity for high-risk plaque classification. hCAPRI offers a low-cost, real-time, and contrast-free approach for carotid plaque risk imaging.