Alternate access solutions are needed in patients where standard transfemoral delivery of transcatheter aortic valve replacement (TAVR) devices is deemed prohibitive. We present a case of a 78-year-old male patient with a past medical history significant for severe aortic arch disease, peripheral artery disease, and symptomatic aortic stenosis requiring an alternative access solution for TAVR. The combination of an axillary conduit with a transcarotid arterial revascularization arterial and venous sheath was utilized to create an access point for the TAVR device and an avenue for cerebral embolic protection with passive cerebral perfusion.
13 October 2026 in European Journal of Vascular and Endovascular Surgery
This study reports midterm outcomes for the GORE® EXCLUDER® Iliac Branch Endoprosthesis (IBE) for patients enrolled in the Global Registry for Endovascular Aortic Treatment (GREAT). Retrospective analysis of the prospective, multicenter GREAT registry (NCT01658787) evaluated a total of 94 patients who received the IBE as part of routine clinical practice. The all-cause mortality rate among patients treated with IBE in the GREAT registry at five-years was 14.3%, the cumulative mortality rate was 23.4%, and aortic-related mortality was 1.1%. The cumulative reintervention rate was 16.0% through five-years including a device-related reintervention rate of 15.0%. Freedom from all-cause mortality and aortic-related mortality at five-years was 68.7% (57.4-77.6%) and 98.8% (91.8-99.8%), respectively. Freedom from any reintervention and from device- or procedure-related reintervention through five-years was 80.6% (69.7-88.0%) and 82.2% (71.5-89.1%), respectively. The cumulative rate of an endoleak through five-years was 12.8%. Most endoleaks were Type II (7.4%) and Type IB (6.4%). Type III endoleaks were uncommon (2.1%), and no Type IV endoleaks were reported. With regards to device integrity events, there was only a single instance of migration reported in five-years. Aortic rupture was rare with a rate of 1.1%. Patency-related adverse events were uncommon, with a cumulative incidence of 3.2% through five-years with most events occurring during the first two years of follow up. Our findings indicate that the GORE® EXCLUDER® Iliac Branch Endoprosthesis was associated with low rates of aortic-related mortality, aortic rupture, reintervention, endograft migration or fracture, aneurysm growth, and endoleak in a real-world setting. Midterm outcomes observed in this real-world registry were comparable to those reported in a more restrictive investigational device exemption trial.