The failure of the New Orleans regional flood protection systems, and the resultant catastrophic flooding of much of New Orleans during Hurricane Katrina, represents the most costly failure of an engineered system in U.S. history. This paper presents an overview of the principal events that unfolded during this catastrophic hurricane, and then a more detailed look at the early stages of the event as the storm first drove onshore and then began to pass to the east of the main populated areas. The emphasis in this paper is on geotechnical lessons and it also includes broader lessons with regard to the design, implementation, operation, and maintenance of major flood protection systems. This paper focuses principally on the early stages of this disaster, including the initial inundation of Plaquemines Parish along the lower reaches of the Mississippi River as Katrina made landfall, and the subsequent additional early levee breaches and erosion along the eastern flanks of the regional flood protection systems fronting Lake Borgne that resulted in the flooding of the two large protected basins of New Orleans East and St. Bernard Parish. Significant lessons learned include (1) the need for realistic assessment of risk exposure as an element of flood protection policy; (2) the importance of considering erodibility of embankment and foundation soils in levee design and construction; (3) the importance of considering all potential failure modes; and (4) the problems inherent in the construction of major regional systems over extended periods of multiple decades. These are important lessons, as they are applicable to other regional flood protection systems in other areas of the United States, and throughout much of the world.
1 July 2016 in Journal of Geotechnical and Geoenvironmental Engineering
Stiffened slabs-on-grade are one of the most economical solutions for 1- to 3-story buildings on shrink-swell soils. They consist, for example, of 1-m-deep, 0.3-m-wide beams resting on the soil, spaced 4 m apart in both directions covered by a 0.1-m-thick slab-on-grade. The challenge is to optimize the beam depth, width, and spacing for the slab to be stiff enough that the movement of the soil at the edges of the slab will not cause undue bending of the foundation and the structure above it. Indeed, shrink-swell soils are affected by the weather and/or by the irrigation at the edges of the foundation and will swell and shrink as a result. This article presents a new method to design stiffened slabs on grade such that the differential movement divided by the length over which this movement takes place is within tolerable limits. The method gives the beam depth necessary to achieve such stiffness as well as the bending moment and shear force to be resisted. The method is automated in a spreadsheet c...
Stiffened slabs-on-grade are one of the most efficient and inexpensive foundation solutions for lightweight structures on shrink-swell soils. The Ellison Office Building (EOB) is a 1-story steel-framed building founded on a clay formation of high shrink-swell potential. The foundation system of the EOB is composed of a rectangular stiffened slab-on-grade with approximate dimensions of 18.3 by 38.1 m. The slab thickness is 0.1 m, and the depth of all stiffening beams is 1.05 m. Beam spacing distances, center to center, are 3.05 and 3.81 m in the short and long directions, respectively. Exploration of subsurface soil conditions at the EOB site took place to determine soil index properties as well as unsaturated moisture diffusion and volume change characteristics for unsaturated soils. Monitoring the movements of both the slab-on-grade and the 4.5 m soil underneath continued for 2 years after foundation construction, since September 2004. Investigating the EOB foundation performance in light of the ...
The recent flooding and devastation of the greater New Orleans region during hurricane Katrina represented the most costly peace-time failure of an engineered system in North American history. Extensive investigations and analyses have been performed by several major teams in the wake of this disaster, and some very important lessons have been learned. Many of these have very direct and urgent applications to levee systems in other regions throughout the U.S., and the world. Lessons include the importance of proper evaluation of risk and hazard; so that appropriate decisions can be made regarding the levels of expense and effort that should be directed towards prevention of catastrophe, and the levels of post-disaster response capability that should be maintained as well. The making of appropriate decisions, given this information regarding risk levels, is then also important. Also of vital importance are numerous "engineering" lessons regarding analysis, design, construction and maintenance; hard-won lessons with applications to flood protection systems everywhere. We must now do everything possible to capitalize upon these; and to prevent a recurrence of this type of catastrophe in the future.
Post-tensioned foundation slabs is considered as a functional and cost effective solution for playing surfaces on shrink-swell soils such as tennis courts. The post tensioning increases the yield bending moment of the slab and to a lesser extent its stiffness hence, cracking during bending is minimized. Compared with conventional reinforced concrete foundation slabs, cost benefits of the post-tensioned slabs are achieved by reductions in quantities of concrete, steel, and excavation, which in turn reduce labor costs. A tennis court, located in the backyard of Prof. Briaud’s residence in College Station, TX, was founded on a clay formation of high shrink-swell potential. The Briaud’s tennis court (BTC) is a nearly rectangular post-tensioned slab-on-grade with approximate dimensions of 18.3 by 36.6 m and a slab thickness of about 0.1 m. The BTC was constructed in 1990 and has exhibited good foundation slab performance, so far. Subsurface soil conditions at the site were explored, soil index properties were determined and unsaturated soil moisture diffusion and volume change characteristics were assessed. Movements of the post-tensioned court slab were monitored every month for 2 years using 194 surveying points. The period covered was March 2005 to February 2007. The tennis court slab movements are analyzed and discussed in light of subsurface soil moisture diffusion and volume change characteristics. The BTC slab performance showed fluctuations in slab edge movements both heave and drop influenced by seasonal weather variations. Moreover, an adjacent tree significantly affected the BTC slab edge movements’ patterns within its root zone.