28 June 2022 in Computers in Biology and Medicine
21 September 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Ultrasonic guided waves (UGW) propagating in long cortical bone can be measured via the axial transmission method. The characterization of long cortical bone using UGW is a multiparameter inverse problem. The optimal solution of the inverse problem often includes a complex solving process. Deep neural networks (DNNs) are essentially powerful multiparameter predictors based on universal approximation theorem, which are suitable for solving parameter predictions in the inverse problem by constructing the mapping relationship between UGW and cortical bone material parameters. In this study, we investigate the feasibility of applying the multichannel crossed convolutional neural network (MCC-CNN) to simultaneously estimate cortical thickness and bulk velocities (longitudinal and transverse). Unlike the multiparameter estimation in most previous studies, the technique mentioned in this work avoids solving a multiparameter optimization problem directly. The finite-difference time-domain method (FDTD) is performed to obtain the simulated UGW array signals for training the MCC-CNN. The network that is exclusively trained on simulated datasets can predict cortical parameters from the experimental UGW data. The proposed method is confirmed by using FDTD simulation signals and experimental data obtained from four bone-mimicking plates and from ten exvivo bovine cortical bones. The estimated root-mean-squared error (RMSE) in the simulated test data for the longitudinal bulk velocity (VL), transverse bulk velocity (VT), and cortical thickness (Th) is 97 m/s, 53 m/s and 0.089 mm, respectively. The predicted RMSE in the bone-mimicking phantom experiments for VL., VT., and Th is 120 m/s, 80 m/s, and 0.14 mm, respectively. The experimental dispersion trajectories are matched with the theoretical dispersion curves calculated by the predicted parameters in ex-vivo bovine cortical bone experiments. Our proposed method demonstrates a feasible approach for the accurate evaluation of long cortical bones based on UGW.
12 April 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
There is a significant acoustic impedance contrast between the cortical bone and the surrounding soft tissue, resulting in difficulty for ultrasound penetration into bone tissue with high frequency. It is challenging for the conventional pulse-echo modalities to give accurate cortical bone images using uniform sound velocity model. To overcome these limitations, an ultrasound imaging method called full-matrix Fourier-domain synthetic aperture based on velocity inversion (FM-FDSA-VI) was developed to provide accurate cortical bone images. The dual linear arrays were located on the upper and lower sides of the imaging region. After full-matrix acquisition with two identical linear array probes facing each other, travel-time inversion was used to estimate the velocity distribution in advance. Then, full-matrix Fourier-domain synthetic aperture (FM-FDSA) imaging based on the estimated velocity model was applied twice to image the cortical bone, utilizing the data acquired from top and bottom linear array, respectively. Finally, to further improve the image quality, the two images were merged to give the ultimate result. The performance of the method was verified by two simulated models and two bone phantoms (i.e., regular and irregular hollow bone phantom). The mean relative errors of estimated sound velocity in the region-of-interest (ROI) are all below 12%, and the mean errors of cortical section thickness are all less than 0.3 mm. Compared to the conventional synthetic aperture (SA) imaging, the FM-FDSA-VI method is able to accurately image cortical bone with respect to the structure. Moreover, the result of irregular bone phantom was close to the image scanned by microcomputed tomography ( μCT) in terms of macro geometry and thickness. It is demonstrated that the proposed FM-FDSA-VI method is an efficient way for cortical bone ultrasonic imaging.
27 August 2021 in IEEE Sensors Journal
This paper proposes an improved co-prime parallel array (CPPA) configuration for two-dimensional direction of arrival (2-D DOA) estimation. Specifically, the proposed array consists of a CPPA and two extra sensors along the vertical axis. The array aperture is extended through two steps. Firstly, a virtual parallel symmetric co-prime array (ViP-SCPA), consisting of two symmetric co-prime arrays(SCPAs), is constructed by using the conjugate augmented processing(CAP). Secondly, a one-dimensional (1-D) virtual co-array of ViP-SCPA is derived by exploiting the difference and sum co-array of the CPPA. Based on the obtained 1-D virtual co-array of ViP-SCPA, the 2-D DOA estimation is cast as a 1-D DOA estimation problem, for which both subspace-based methods and sparse representation algorithms can be adopted. To evaluate the array apertures of the proposed array, analytical expressions are derived to quantify the achievable number of unique lags, and the maximum number of consecutive lags of the resultant 1-D virtual co-array of ViP-SCPA. Simulation results verify the effectiveness of the proposed configuration by using the classical multiple signal classification (MUSIC) and sparse representation(SR) algorithm respectively.
13 February 2025 in Neurocomputing
28 December 2024 in Engineering Applications of Artificial Intelligence