Airway driving pressure, easily measured as plateau pressure minus PEEP, is a surrogate for alveolar stress and strain. However, the effect of its targeted reduction remains unclear. In this multicentre trial, patients undergoing lung resection surgery were randomised to either a driving pressure group (n=650) receiving an alveolar recruitment/individualised PEEP to deliver the lowest driving pressure or to a conventional protective ventilation group (n=650) with fixed PEEP of 5 cm H2O. The primary outcome was a composite of pulmonary complications within 7 days postoperatively. The modified intention-to-treat analysis included 1170 patients (mean [standard deviation, sd]; age, 63 [10] yr; 47% female). The mean driving pressure was 7.1 cm H2O in the driving pressure group vs 9.2 cm H2O in the protective ventilation group (mean difference [95% confidence interval, CI]; -2.1 [-2.4 to -1.9] cm H2O; P<0.001). The incidence of pulmonary complications was not different between the two groups: driving pressure group (233/576, 40.5%) vs protective ventilation group (254/594, 42.8%) (risk difference -2.3%; 95% CI, -8.0% to 3.3%; P=0.42). Intraoperatively, lung compliance (mean [sd], 42.7 [12.4] vs 33.5 [11.1] ml cm H2O-1; P<0.001) and Pao2 (median [inter-quartile range], 21.5 [14.5 to 30.4] vs 19.5 [13.5 to 29.1] kPa; P=0.03) were higher and the need for rescue ventilation was less frequent (6.8% vs 10.8%; P=0.02) in the driving pressure group. In lung resection surgery, a driving pressure-guided ventilation improved pulmonary mechanics intraoperatively, but did not reduce the incidence of postoperative pulmonary complications compared with a conventional protective ventilation. NCT04260451.
(1) Background: Robot-assisted laparoscopic prostatectomy (RALP) is preferred over open prostatectomy because it offers superior surgical outcomes and better postoperative recovery. The steep Trendelenburg position and pneumoperitoneum required in Robot-assisted laparoscopic prostatectomy, however, increase intracranial pressure (ICP). The present study aimed to evaluate the effects of elevated ICP on the quality of emergence from anesthesia. (2) Methods: Sixty-seven patients undergoing RALP were enrolled. We measured optic nerve sheath diameter at four timepoints during surgery. Primary outcome was inadequate emergence in the operating room (OR). Secondary outcomes were postoperative neurologic deficits of dizziness, headache, delirium, cognitive dysfunction, and postoperative nausea and vomiting (PONV). (3) Results: A total of 69 patients were screened for eligibility and 67 patients completed the study and were included in the final analysis. After establishing pneumoperitoneum with the Trendelenburg position, ONSD increased compared to baseline by 11.4%. Of the 67 patients, 36 patients showed an increase of 10% or more in optic nerve sheath diameter (ONSD). Patients with ΔONSD ≥ 10% experienced more inadequate emergence in the OR than those with ΔONSD < 10% (47.2% vs. 12.9%, p = 0.003). However, other variables related to the quality of emergence from anesthesia did not different significantly between groups. Similarly, neurologic deficits, and PONV during postoperative day 3 showed no significant differences. (4) Conclusions: ICP elevation detected by ultrasonographic ONSD measurement was associated with a transient, inadequate emergence from anesthesia.
1 January 2014 in Korean Journal of Anesthesiology
A patient with pulmonary alveolar proteinosis underwent whole lung lavage of the right lung. Lavage of the left lung was not immediately possible because of severe hypoxemia. Three days later, after correction of hypoxemia, we re-attempted the left lung lavage. However, the patient had severe hypoxemia (SpO2 < 80%) within a few minutes of performing right one lung ventilation (OLV). On bronchoscopic examination, proper tube location was confirmed. Bronchodilator nebulization and steroid injection were attempted with no effect. While searching for the cause of the hypoxemia, we found that the breath sound from the right lung had become very weak and distant compared with that from initial auscultation. Right pneumothorax was diagnosed on chest X-ray and a chest tube was inserted. After confirming pneumothorax resolution, we re-tried right OLV and were able to proceed with the left lung lavage without signs of aggravating air leak, loss of tidal volume, or severe hypoxemia.