1 March 2019 in International Journal of Thermal Sciences
1 August 2010 in Computers & Fluids
The aim of this paper is to analyze the aeroelastic processes developed during the starting phase of a rocket engine via a coupling fluid/structure code. This analysis gives a better understanding of the behavior of the structure as the shock waves propagate inside the engine nozzle. The gasdynamics Euler equations are solved for the fluid and constitutive linear elastic solid assuming large displacements and rotations with no material damping is adopted for the structure. The coupling of each subproblem is carried out with a Gauß–Seidel algorithm over the fluid and structure states. For the fluid problem an ALE (Arbitrary Lagrangian–Eulerian) formulation is used. It allows us to define a reference system following the moving boundaries while the structure is deformed. The code is validated with a study of the flutter phenomena that may occur when a supersonic compressible fluid flows over a flat solid plate. Regarding the rocket engine ignition problem, a modal analysis of the structure is performed in order to analyze the eigenfrequency shifts when considering the coupling with the fluid flow.Fil: Garelli, Luciano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Santa Fe. Instituto de Desarrollo Tecnológico Para la Industria Química (i); ArgentinaFil: Paz, Rodrigo Rafael. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Santa Fe. Instituto de Desarrollo Tecnológico Para la Industria Química (i); ArgentinaFil: Storti, Mario Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Santa Fe. Instituto de Desarrollo Tecnológico Para la Industria Química (i); Argentin
1 March 2016 in Computer Methods in Applied Mechanics and Engineering
6 September 2011 in International Journal for Numerical Methods in Fluids
16 June 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Nowadays, as an alternative to conventional mineral oils used for cooling in distribution transformers, environment-friendly ester oils are getting more attention. For this reason, the main objective of this work was to compare the cooling efficiency of both types of coolants in the medium-power distribution transformer under different ambient conditions. It was conducted by the development of a validated coupled numerical model that included all thermal, flow and electromagnetic phenomena. Moreover, all the calculations were carried out for mineral, synthetic and natural ester oils. As a result, the coupled CFD model determined the hot-spot temperature within the transformer tank at three ambient temperatures on the basis of the local distribution of the power losses in windigns and core that were delivered from the electromagnetic submodel. The investigated ambient temperatures of -10, 20 and 30°C represented summertime and wintertime for two climate conditions. The numerical results also showed a satisfactory agreement with the measured temperature values recorded in the analysed distribution transformer with mineral oil. In addition, it was presented that the highest hot-spot temperature of 94.6°C was reached for the case of natural ester oil at 30°C of the ambient temperature representing maximum monthly averaged Argentinian climate conditions. In these conditions, the hot-spot temperature transformer with mineral oil was only 1.6 K lower. Furthermore, one of the investigated synthetic ester oil allowed to reach even better cooling effectiveness than in the case of mineral oil. Therefore, more effective cooling connected with environment-friendly characteristics encourages to use biodegradable oils for distribution transformers.
11 August 2010 in Computers & Fluids