Benoit Genestie

Benoit Genestie

Auto-generated profile, based on publicly available information

Benoit Genestie

Univ. Artois, LGCgE, EA 4515, IUT Béthune, Béthune, France

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
TCT. Chartier
T. Chartier
OColivier carpentier
olivier carpentier
BGB. Genestie
B. Genestie
JHjean christophe Hornez
jean christophe Hornez
FMF. Monchau
F. Monchau
This work is based on the production of a bioprobe that is compatible with magnetic resonance imaging (MRI) for laser-induced thermotherapy (LITT) in liver cancer laser therapy. This probe is made of an alumina tube (3-mm diameter) in which an optical fibre is centred and fixed. A shooting window (20mm) is created using a mechanical rectifier. The device is then consolidated by the injection of a transparent and heat-resistant resin. Through numerical modelling, the thermal power damping of the laser source is evaluated as well as the propagation of the heat in the ex vivo liver tissue according to different heating scenarios. These analyses allow for an estimation of the irradiated volume. Ex vivo tests were performed on bovine liver to confirm the adequacy of the bioprobe for LITT and of the irradiated volumes predicted by the numerical model. There was a difference of 8% between the simulations and ex vivo experiments. The pulsed mode heating scenario was the most effective under the experimental conditions.

22 April 2020 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
PCPierre-Yves Cresson
Pierre-Yves Cresson
GBGhizlane Boussatour
Ghizlane Boussatour
SLShuo Li
Shuo Li
BGBenoit Genestie
Benoit Genestie
Nicolas JolyNicolas Joly
Nicolas Joly
TLTuami Lasri
Tuami Lasri
In this article, the dielectric properties of a biosourced polymer are investigated. To that end, coplanar transmission lines were fabricated on a 600-μm thick cellulose palmitate substrate by using a photolithographic process and a transfer technique. The S-parameters of the transmission lines were measured in a broad microwave frequency band spanning from 10 to 67 GHz in order to determine the propagation constant. From these data, the complex dielectric permittivity was extracted by using two analytical methods (RLCG method, based on resistance, inductance, capacitance and conductance of transmission lines and conformal mapping method) and a numerical one [finite element method (FEM)]. The three methods allow distinguishing the dielectric losses from the total measured losses of the transmission lines. Finally, the dielectric constant and the loss tangent of this biopolymer were compared to the data of common and commercially available substrates: polyimide and polyethylene naphthalate.