21 January 2026 in IEEE Sensors Journal
The pendulous integrating gyroscopic accelerometer (PIGA) sensor has an eccentric pendulum and continuous precession characteristics. The motion of its float is more complex compared to that of a gyroscope. Now there is no method for calibrating magnetic suspension disturbance torque of gyroscopic accelerometer. To address this, the mechanism by which disturbance torque affects instrument output when magnetic suspension system overcomes transverse pendulum torque is analyzed. A novel method for calibrating magnetic suspension disturbance torque by injecting excitation into the magnetic suspension control loop is proposed. The calibration test is carried out on the PIGA to obtain the equivalent force arm of the electromagnetic force of the PIGA. The equivalent force arm is multiplied by the electromagnetic force at the actual working time to get the disturbance torque of magnetic suspension. Accordingly, the influence of the magnetic suspension disturbance torque on the magnitude of PIGA precision is analyzed, and then the concerned error of the PIGA can be obtained. The tests in six PIGA showed consistency in the order of magnitude of the equivalent force arm of the electromagnetic force calibrated by the disturbance torque under different overload conditions. Typically, the magnetic suspension disturbance torque ranges from 10−9 to 7 × 10−8 Nm. This result verifies the effectiveness of the calibration method proposed in this paper. The method provides a new idea for compensating for the output error of the PIGA sensor, which is of an important reference value to improve the accuracy of the sensor.