1 April 2001 in Progress in Structural Engineering and Materials
1 February 2008 in Journal of Composites for Construction
This paper presents a novel anchoring technique for strengthening reinforced concrete beams with prestressed carbon fiber- reinforced polymer (CFRP) sheets. Permanent steel anchors are commonly used for the application of prestressed CFRP sheets. The steel anchors are, however, susceptible to corrosion and may not blend into the aesthetics of the original structure. As a result, it may be preferable to remove the steel anchors after transferring the required prestress to the structure with minimal losses of sustained prestress. A technique for replacing the steel anchors with nonmetallic anchors is investigated and reported herein. Nine doubly reinforced concrete beams are tested with various types of nonmetallic anchor systems such as nonanchored U-wraps, mechanically anchored U-wraps, and CFRP sheet-anchored U-wraps. The developed nonmetallic anchorages successfully transfer the sustained prestress in the CFRP sheets with insignificant prestress losses. A closed-form solution for the transfer of prestre...
1 February 2008 in Journal of Composites for Construction
This paper presents the flexural behavior of reinforced concrete beams strengthened with prestressed carbon fiber-reinforced polymer (CFRP) sheets using nonmetallic anchor systems. The developed nonmetallic anchor systems replace the permanent steel anchorage. Nine doubly reinforced concrete beams are tested with various types of nonmetallic anchor systems such as nonanchored U-wraps, mechanically anchored U-wraps, and CFRP sheet-anchored U-wraps. The flexural behavior of the tested beams, including detailed failure modes of each nonmetallic anchor system, is investigated. The study shows that the developed nonmetallic anchors are more effective in resisting peeling-off cracks compared to the permanent steel anchors and the beams strengthened with the nonmetallic anchors provide comparable load-carrying capacity with respect to the steel anchored control beam.
1 July 2006 in Journal of Bridge Engineering
For military and civilian applications, there exists a need for lightweight, inexpensive, short-span bridges that can be easily transported and erected with minimal equipment. Owing to its favorable properties, fiber-reinforced polymer (FRP) has been shown to be feasible for the construction of such bridges. Investigations into the behavior of a short-span bridge structural concept, adapted to the material properties of commercially available glass FRP (GFRP) pultruded products, are presented. A 4.8-m span prototype was built from GFRP sections, bonded throughout to form a tapered box beam, with a width of 1.2 m and a height at midspan of approximately 0.5 m . The box beam represents a single trackway of a double-trackway bridge, whose trackways could be connected by light structural elements. The quasi-static and dynamic behavior of the prototype box beam was investigated in ambient laboratory and field conditions to assess the design and construction techniques used, with a view to designing a full-scal...
1 August 2003 in Advances in Structural Engineering
Six one-way reinforced concrete slabs were constructed and tested to investigate the effectiveness of using prestressed carbon fibre reinforced polymer (CFRP) sheets to strengthen concrete slabs subjected to fatigue loading. The slabs were 90mm × 1000mm × 3000mm and reinforced with 11.3mm diameter steel reinforcing bars. The slabs were tested in two groups of three slabs. In each group, one slab was unstrengthened and used as a control, the second slab was strengthened with non-prestressed FRP sheets and the third slab was strengthened with prestressed sheets. For the first group, the loading range for the three slabs was based on the loads that induced in the reinforcing steel of the control slab stresses that ranged between 10 and 95 percent of the steel yield strength. For the second group, the loading range chosen for the three slabs induced steel stresses in its control slab that ranged between 30 and 95 percent of the steel yield strength. Therefore, the first group of slabs was subjected to a higher load amplitude but lower mean stress than the second group. The CFRP strengthened slabs of the second group were externally loaded while applying the CFRP sheets, to represent the sustained load that may be associated with field strengthening conditions. The test results confirmed that strengthening reinforced concrete slabs with bonded CFRP sheets, especially prestressed CFRP sheets, increases fatigue life. Common to strengthening with non-prestressed and prestressed CFRP sheets are that compared to the control slabs, strains in the steel reinforcement, plastic creep strains in the concrete, and deflections are all decreased, with greater decreases in all these observed with prestressed CFRP sheets. Crack widths are greatly reduced when the CFRP sheets are prestressed. Since fatigue failure of the internal steel occurred at the location of large cracks that were repetitively opened and closed, reducing the crack widths contributes to achieving longer fatigue life. Finally, the presence of anchors at the ends of the CFRP sheets can delay the ultimate fatigue failure of CFRP strengthened slabs by delaying sheet debonding failures.