13 January 2023 in IEEE Access
In current days, sensor nodes are deployed in hostile environments for various military and commercial applications. Sensor nodes are becoming faulty and having adverse effects on the network if they are not diagnosed and informed of the fault status to other nodes. Fault diagnosis is difficult when the nodes behave at fault sometimes and provide good data at other times. The intermittent disturbances may be random or kind of spikes either in regular or irregular intervals. In literature, the fault diagnosis algorithms are based on statistical methods using repeated testing or machine learning. To avoid more complex and time consuming repeated test processes and computationally complex machine learning methods, we proposed a one shot likelihood ratio test (LRT) here to determine the fault status of the sensor node. The proposed method measures the statistics of the received data over a certain period of time and then compares the likelihood ratio with the threshold value associated with a certain tolerance limit. The simulation results using a real time data set show that the new method provides better detection accuracy (DA) with the minimum false positive rate (FPR) and false alarm rate (FAR) over the modified three sigma test. LRT based hybrid fault diagnosis method detecting the fault status of a sensor node in a wireless sensor network (WSN) for real time measured data with 100% DA, 0% FAR, and 0% FPR if the probability of the data from faulty node exceeds 25%.