30 July 2022 in Radiation Detection Technology and Methods
1 August 2023 in Journal of Instrumentation
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
1 August 2023 in Journal of Instrumentation
As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures. The results on the electrical properties of the irradiated CE silicon sensors are presented.
10 March 2020 in Radiation Detection Technology and Methods
Background: The Cylindrical Gas Electron Multiplier Inner Tracker (CGEM-IT) is one of the candidates for the replacement of the current BESIII inner drift chamber, which has developed serious aging effects due to beam-related backgrounds. Purpose: To build a full digitization model, it is necessary to understand the electron drift behavior and signal induction. Methods: A simulation study based on Garfield++ and ANSYS software has been performed. Results: Parameters describing the Lorentz angle, diffusion effect, drift time, multiplication, and induction are obtained from the Garfield++ simulation. Based on these results, a preliminary digitization model is implemented in the BESIII offline software system.
18 May 2026 in Physical Review Letters
A search for C P violation with an entangled system of Ξ − Ξ ¯ + pairs is performed, using ( 10 , 087 ± 44 ) × 10 6 J / ψ events collected with the BESIII experiment. A nine-dimensional helicity amplitude is used to fit e + e − → J / ψ → Ξ − Ξ ¯ + and its subsequent decays. The Ξ − and Ξ ¯ + decay parameters are determined with higher precision compared to the best results reported so far. Furthermore, the strong phase difference, ( δ P − δ S ) = ( 0.3 ± 1.2 ± 0.2 ) × 10 − 2 rad , and the weak phase difference, ( ξ P − ξ S ) = ( − 0.2 ± 1.2 ± 0.1 ) × 10 − 2 rad , are directly determined. These are the most precise measurements to date. The C P asymmetry observables A C P Ξ = ( − 7.8 ± 4.8 ± 0.8 ) × 10 − 3 and Δ ϕ C P Ξ = ( 0.6 ± 5.1 ± 0.2 ) × 10 − 3 rad are determined, which are consistent with C P conservation. In addition, independent measurements of the Λ decay parameter and C P asymmetry A C P Λ = ( − 2.9 ± 4.3 ± 0.7 ) × 10 − 3 are also obtained, which are in agreement with the previous measurements, but with much improved precision.
17 February 2026 in Physical Review D
We report a direct search for a new gauge boson, X , with a mass of 17 MeV / c 2 , which could explain the anomalous excess of e + e − pairs observed in the Be 8 nuclear transitions. The search is conducted in the charmonium decays χ c J → X J / ψ ( J = 0 , 1 , 2 ) via the radiative transition ψ ( 3686 ) → γ χ c J using ( 2712.4 ± 14.3 ) × 10 6 ψ ( 3686 ) events collected with the BESIII detector at the BEPCII collider. No significant signal is observed, and the updated upper limit on the coupling strength of charm quark and the new gauge boson, ε c , is set to be | ε c | < 1.2 × 10 − 2 at 90% confidence level. We also report new constraints on the mixing strength ε between the Standard Model photon and dark photon γ ′ in the mass range from 5 to 300 MeV / c 2 . The upper limits at 90% confidence level vary within ( 2.5 – 17.5 ) × 10 − 3 depending on the γ ′ mass.