Alexander C. Ziedas

Alexander C. Ziedas

Auto-generated profile, based on publicly available information

Alexander C. Ziedas

Henry Ford Providence Orthopaedic Surgery Residency Program Southfield Michigan U.S.A.

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in JBJS Open Access
Verified
Journal Article
Open access
CGCaleb M. Gulledge
Caleb M. Gulledge
DSD. Grace Smith
D. Grace Smith
AZAlexander Ziedas
Alexander Ziedas
SMStephanie J. Muh
Stephanie J. Muh
VMVasilios Moutzouros
Vasilios Moutzouros
EMEric C. Makhni
Eric C. Makhni
Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) computer adaptive tests (CATs) have emerged as an efficient technique for measuring patient-reported outcomes among orthopaedic patients. The purpose of this study was to investigate the floor and ceiling (F/C) effects, time to completion (TTC), and question burden of PROMIS CATs administered to patients presenting to a shoulder and sports medicine orthopaedic clinic. Methods: Patients prospectively completed PROMIS CATs including the physical function (PROMIS-PF) or upper-extremity function (PROMIS-UE), pain interference (PROMIS-PI), and depression (PROMIS-D) domains at their initial encounter and were retrospectively included in this study. Adult patients indicating a single problem involving either the shoulder or knee were included. Patients were also grouped as either preoperative or nonoperative. F/C effects were defined as the proportion of respondents scoring the highest (ceiling) or lowest (floor) possible score across a given domain. Results: Included were 2,952 patients (average age, 51.0 ± 16.9 years). The PROMIS-UE, PROMIS-PF, and PROMIS-PI demonstrated negligible F/C effects across all shoulder and knee patients (<2%). The PROMIS-D displayed moderate to significant floor effects (13.9% to 18.9%) and a 0% ceiling effect in all main patient groups. The mean TTC and mean question burden of the PROMIS-UE, PROMIS-PF, and PROMIS-PI ranged from 45.3 to 54.4 seconds and 4.1 to 4.9 questions for all patient groups, while the PROMIS-D exhibited a TTC ranging from 20.9 to 38.6 seconds for all groups and a question burden that ranged from 6.2 to 6.7 questions. Conclusions: The PROMIS-PF, PROMIS-UE, and PROMIS-PI demonstrated favorable F/C effects, TTC, and question burden among both nonoperative and preoperative patients. These findings justify consideration of the PROMIS-PF, PROMIS-UE, and PROMIS-PI for clinical and research applications involving shoulder and knee sports medicine patients. Additionally, we found moderate to significant floor effects for the PROMIS-D in all patient groups, which may be multifactorial in nature and may not be unexpected in patients with an isolated joint concern. Clinical Relevance: This study highlights the psychometric properties of PROMIS CAT forms for knee and shoulder patients. Understanding these basic properties is important in considering the adoption of PROMIS CAT forms for patients with musculoskeletal conditions.

13 February 2022 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
JTJoseph S. Tramer
Joseph S. Tramer
NYNikhil R. Yedulla
Nikhil R. Yedulla
AZAlexander C. Ziedas
Alexander C. Ziedas
MPMit Patel
Mit Patel
SFSreten Franovic
Sreten Franovic
EMEric C. Makhni
Eric C. Makhni

23 April 2025 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
AZAlexander C. Ziedas
Alexander C. Ziedas
JMJefferey Michaelson
Jefferey Michaelson
DKDavid Knesek
David Knesek
MLMichael Laker
Michael Laker
TFTodd Frush
Todd Frush
DMDavid C. Markel
David C. Markel

1 March 2022 in Seminars in Arthroplasty: JSES
Verified
Journal Article
Closed access
JWJonathan Warren
Jonathan Warren
APAlexander D. Pietroski
Alexander D. Pietroski
SFSreten Franovic
Sreten Franovic
AZAlexander Ziedas
Alexander Ziedas
NYNikhil Yedulla
Nikhil Yedulla
SMStephanie J. Muh
Stephanie J. Muh


21 September 2021 in Arthroscopy Techniques
Verified
Journal Article
Open access
JTJoseph S. Tramer
Joseph S. Tramer
HEHardy Evans
Hardy Evans
AZAlexander C. Ziedas
Alexander C. Ziedas
ASAlexander J. Swantek
Alexander J. Swantek
SJSteven E. Jordan
Steven E. Jordan
EMEric C. Makhni
Eric C. Makhni
Quadriceps tendon ruptures compromise the knee extensor mechanism and cause an inability to ambulate and significant functional limitations. Therefore, the vast majority of quadriceps tendon ruptures are indicated for operative intervention to restore patient mobility and function. Although these injuries were traditionally repaired using a transosseous repair technique, recent literature has shown that suture anchor repair may offer biomechanical advantages. Additionally, research in other areas of orthopaedics has found that a double‐row suture anchor construct can offer additional biomechanical strength to tendinous repair. This technical note describes a safe and effective quadriceps tendon repair using a double‐row suture anchor construct. Technique Video: video See video under supplementary data.