Sazgar Burhan

Sazgar Burhan

Auto-generated profile, based on publicly available information

Sazgar Burhan

Universität zu Lübeck

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
SBSazgar Burhan
Sazgar Burhan
NDNicolas Detrez
Nicolas Detrez
KRKatharina Rewerts
Katharina Rewerts
PSPaul Strenge
Paul Strenge
SBSteffen Buschschlüter
Steffen Buschschlüter
RHRobert Huber
Robert Huber
During neuro-oncologic surgery, phase-sensitive optical coherence elastography (OCE) can be valuable for distinguishing between healthy and diseased tissue. However, the phase unwrapping process required to retrieve the original phase signal is a challenging and critical task. To address this issue, we demonstrate a one-dimensional unwrapping algorithm that recovers the phase signal from a 3.2 MHz OCE system. With a processing time of approximately 0.11 s per frame on the GPU, multiple 2π wraps are detected and corrected. By utilizing this approach, exact and reproducible information on tissue deformation can be obtained with pixel accuracy over the entire acquisition time. Measurements of brain tumor-mimicking phantoms and human ex vivo brain tumor samples verified the algorithm's reliability. The tissue samples were subjected to a 200 ms short air pulse. A correlation with histological findings confirmed the algorithm's dependability.

12 September 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SBSazgar Burhan
Sazgar Burhan
MGMadita Göb
Madita Göb
MPMario Pieper
Mario Pieper
TLTjalfe Laedtke
Tjalfe Laedtke
TGThorge Grahl
Thorge Grahl
RHRobert Huber
Robert Huber
Dynamic optical coherence tomography (dOCT) enables high-resolution, label-free 3D tissue imaging with functional contrast, offering a potential advancement in kidney transplant viability assessment. Currently, no widely accepted non-invasive method provides an objective evaluation of transplant viability, as conventional imaging lacks the resolution to assess microvascular integrity and cellular dynamics. However, the clinical use of available dOCT systems is limited by prolonged imaging times that hinder clear visualization of tissue dynamics. To address these challenges, this paper presents a swept-source 3.2 MHz-OCT system for dynamic, high-speed, extended-area imaging. The system integrates an optimized inter-volume scan protocol and a micrometer-precision linear robot, enabling extended‑scale tissue imaging over an area of about 2.6 × 2.6 mm2. Using freshly excised porcine kidney tissue, we demonstrate recent advancements and challenges in MHz-dOCT for kidney imaging. Identified anatomical features are thoroughly examined, compared across resolutions, and validated through histology to assess the system’s clinical potential.

22 October 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
NDNicolas Detrez
Nicolas Detrez
SBSazgar Burhan
Sazgar Burhan
KRKatarina Rewerts
Katarina Rewerts
JKJessica Kren
Jessica Kren
SBSteffen Buschschlüter
Steffen Buschschlüter
RBRalf Brinkmann
Ralf Brinkmann
Objective: Optical coherence elastography (OCE) has been introduced for several medical applications to determine tissue mechanical parameters. However, in order to measure sensitive healthy tissue like brain in vivo, the excitation force needs to be carefully controlled and as low as possible (under 100 µN). Preferably, the excitation should be applied in a non-contact manner. Methods: In this work, an air-jet excitation source for this specific purpose has been developed and characterized. The design focus was set on the exact measurement and control of the generated excitation force to better comply with in vivo medical safety requirements during surgery. Results: Therefore, an excitation force control and measurement system based on the applied gas flow was developed. Conclusion: This system can generate short, high dynamic air-puffs lasting fewer than 5 ms, as well as quasi-static excitation forces lasting 700 ms. The force range covers 1µN to 40 mN with a force error margin between 0.1% and 16% in the relevant range. The excitation source, in conjunction with a 3.2 MHz optical coherence system, enables phase-based, dynamic, and quasi steady-state elastography, as well as robust non-contact classical indentation measurements. Significance: The presented system is a preliminary prototype intended for further development into a clinical version to be used in situ during brain tumor surgery.

12 February 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
NDNicolas Detrez
Nicolas Detrez
SBSazgar Burhan
Sazgar Burhan
JKJessica Kren
Jessica Kren
JMJakob Matschke
Jakob Matschke
CHChristian Hagel
Christian Hagel
RBRalf Brinkmann
Ralf Brinkmann
Optical coherence elastography (OCE) is a powerful imaging modality for assessing the mechanical properties of biological tissues. We employed an OCE system based on an Optores OMES 3.2 MHz OCT platform combined with an in-house developed air-jet excitation source to characterize healthy and tumorous (meningioma) human brain tissue. This paper presents a comprehensive software framework for processing large OCE datasets, enabling robust extraction of characteristic features from phase-derived displacement data and calculation of mechanical proxy parameters for detailed tissue characterization. Feature detection is achieved using a modified triangle threshold algorithm applied to the displacement curves from the OCE phase data. Extensive pre- and post-processing steps, including percentile-based filtering and adaptive histogram equalization, are applied to mitigate phase unwrapping errors and enhance visualization of the high dynamic range of OCE data. Exemplary measurements on human brain tumor samples demonstrate the framework’s ability to differentiate between tissue types, highlighting its potential for future clinical and research applications.

27 March 2026 in Journal of Biomedical Optics
Verified
Journal Article
Open access
SBSazgar Burhan
Sazgar Burhan
BSBerenice Schulte
Berenice Schulte
MGMadita Göb
Madita Göb
ASAwanish Pratap Singh
Awanish Pratap Singh
BMBayan Mustafa
Bayan Mustafa
RHRobert Huber
Robert Huber
SignificanceEndoscopic optical coherence tomography (OCT) is a valuable tool for rectal imaging, enabling noninvasive visualization of transmural structures with near-histological resolution, critical for accurate tumor staging and diagnostic/therapeutic monitoring. However, anatomical variability of the rectum and the resulting changes in tissue-to-probe distance challenge optimal circumferential imaging.AimWe aim to develop a dual-mode endoscopic OCT system, enabling real-time switching between high-detail and extended-range imaging for improved assessment of rectal wall morphology under varying anatomical conditions.ApproachA single fiber-optic ferrule containing two fibers with differing mode fields was integrated into a MHz-OCT rectoscope, enabling an extended-range mode for full circumferential imaging and a high-detail mode for close examination of fine structures with seamless live switching mechanism. The system was tested in situ on a postmortem human rectum preserved with ethanol-glycerol-lysoformin fixation.ResultsPostmortem rectum imaging demonstrated the feasibility of real-time switching between the two modes. Extended-range imaging provided full circumferential coverage, whereas high-detail imaging revealed distinct rectal wall layers and fine transmural structures, validated by histological correlation.ConclusionsThe dual-mode MHz-OCT system offers a flexible and practical solution for adaptive rectal imaging, providing high-resolution detail and full circumferential coverage with the potential to enhance diagnostics and treatment monitoring.

1 January 2025
Verified
Conference Paper
Closed access
PDF file
SBSazgar Burhan
Sazgar Burhan
MGMadita Göb
Madita Göb
GHGereon Hüttmann
Gereon Hüttmann
RHRobert Huber
Robert Huber
We investigate advanced scanning strategies to improve speed in dynamic MHz-OCT, demonstrating that temporally non-uniform sampling outperforms uniform scanning by achieving faster imaging speeds while largely preserving image clarity.