Patricia V. Lawford

Patricia V. Lawford

Auto-generated profile, based on publicly available information

Patricia V. Lawford

Department of Infection, Immunity and Cardiovascular Disease, Medical School , Beech Hill Road, Sheffield, S102TN , UK

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2019 in Medical Engineering & Physics
Verified
Journal Article
Closed access
DHD. Rodney Hose
D. Rodney Hose
PLPatricia V. Lawford
Patricia V. Lawford
WHWouter Huberts
Wouter Huberts
LHLeif Rune Hellevik
Leif Rune Hellevik
SOStig W. Omholt
Stig W. Omholt
FVFrans N. van de Vosse
Frans N. van de Vosse
The aim of this position paper is to provide a brief overview of the current status of cardiovascular modelling and of the processes required and some of the challenges to be addressed to see wider exploitation in both personal health management and clinical practice. In most branches of engineering the concept of the digital twin, informed by extensive and continuous monitoring and coupled with robust data assimilation and simulation techniques, is gaining traction: the Gartner Group listed it as one of the top ten digital trends in 2018. The cardiovascular modelling community is starting to develop a much more systematic approach to the combination of physics, mathematics, control theory, artificial intelligence, machine learning, computer science and advanced engineering methodology, as well as working more closely with the clinical community to better understand and exploit physiological measurements, and indeed to develop jointly better measurement protocols informed by model-based understanding. Developments in physiological modelling, model personalisation, model outcome uncertainty, and the role of models in clinical decision support are addressed and 'where-next' steps and challenges discussed.

14 July 2020 in Cardiovascular Research
Verified
Journal Article
Open access
PDF file
PMPaul D Morris
Paul D Morris
RGRebecca Gosling
Rebecca Gosling
IZIwona Zwierzak
Iwona Zwierzak
HEHolli Evans
Holli Evans
LALouise Aubiniere-Robb
Louise Aubiniere-Robb
JGJulian Gunn
Julian Gunn
Ischaemic heart disease is the reduction of myocardial blood flow, caused by epicardial and/or microvascular disease. Both are common and prognostically important conditions, with distinct guideline-indicated management. Fractional flow reserve (FFR) is the current gold-standard assessment of epicardial coronary disease but is only a surrogate of flow and only predicts percentage flow changes. It cannot assess absolute (volumetric) flow or microvascular disease. The aim of this study was to develop and validate a novel method that predicts absolute coronary blood flow and microvascular resistance (MVR) in the catheter laboratory. A computational fluid dynamics (CFD) model was used to predict absolute coronary flow (QCFD) and coronary MVR using data from routine invasive angiography and pressure-wire assessment. QCFD was validated in an in vitro flow circuit which incorporated patient-specific, three-dimensional printed coronary arteries; and then in vivo, in patients with coronary disease. In vitro, QCFD agreed closely with the experimental flow over all flow rates [bias +2.08 mL/min; 95% confidence interval (error range) −4.7 to +8.8 mL/min; R2 = 0.999, P < 0.001; variability coefficient <1%]. In vivo, QCFD and MVR were successfully computed in all 40 patients under baseline and hyperaemic conditions, from which coronary flow reserve (CFR) was also calculated. QCFD-derived CFR correlated closely with pressure-derived CFR (R2 = 0.92, P < 0.001). This novel method was significantly more accurate than Doppler-wire-derived flow both in vitro (±6.7 vs. ±34 mL/min) and in vivo (±0.9 vs. ±24.4 mmHg). Absolute coronary flow and MVR can be determined alongside FFR, in absolute units, during routine catheter laboratory assessment, without the need for additional catheters, wires or drug infusions. Using this novel method, epicardial and microvascular disease can be discriminated and quantified. This comprehensive coronary physiological assessment may enable a new level of patient stratification and management.

5 February 2021 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
PDF file
KLKatherine Lal
Katherine Lal
RGRebecca Gosling
Rebecca Gosling
MGMina Ghobrial
Mina Ghobrial
GWGareth J Williams
Gareth J Williams
VRVignesh Rammohan
Vignesh Rammohan
PMPaul D Morris
Paul D Morris
To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or ‘virtual’ fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of operator experience with these methods upon vFFR accuracy remains unknown. We investigated variability in vFFR results based upon operator experience with image-based computational modelling techniques. Virtual fractional flow reserve was computed using a proprietary method (VIRTUheart) from the invasive angiograms of patients with coronary artery disease. Each case was processed by an expert (>100 vFFR cases) and a non-expert (<20 vFFR cases) operator and results were compared. The primary outcome was the variability in vFFR between experts and non-experts and the impact this had upon treatment strategy (PCI vs. conservative management). Two hundred and thirty-one vessels (199 patients) were processed. Mean non-expert and expert vFFRs were similar overall [0.76 (0.13) and 0.77 (0.16)] but there was significant variability between individual results (variability coefficient 12%, intraclass correlation coefficient 0.58), with only moderate agreement (κ = 0.46), and this led to a statistically significant change in management strategy in 27% of cases. Variability was significantly lower, and agreement higher, for expert operators; a change in their recommended management occurred in 10% of repeated expert measurements and 14% of inter-expert measurements. Virtual fractional flow reserve results are influenced by operator experience of vFFR processing. This had implications for treatment allocation. These results highlight the importance of training and quality assurance to ensure reliable, repeatable vFFR results.

5 September 2022 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
PDF file
RGRebecca C Gosling
Rebecca C Gosling
EGEleanor Gunn
Eleanor Gunn
HWHua Liang Wei
Hua Liang Wei
YGYuanlin Gu
Yuanlin Gu
VRVignesh Rammohan
Vignesh Rammohan
PMPaul D Morris
Paul D Morris
Angiography-derived fractional flow reserve (angio-FFR) permits physiological lesion assessment without the need for an invasive pressure wire or induction of hyperaemia. However, accuracy is limited by assumptions made when defining the distal boundary, namely coronary microvascular resistance (CMVR). We sought to determine whether machine learning (ML) techniques could provide a patient-specific estimate of CMVR and therefore improve the accuracy of angio-FFR. Patients with chronic coronary syndromes underwent coronary angiography with FFR assessment. Vessel-specific CMVR was computed using a three-dimensional computational fluid dynamics simulation with invasively measured proximal and distal pressures applied as boundary conditions. Predictive models were created using non-linear autoregressive moving average with exogenous input (NARMAX) modelling with computed CMVR as the dependent variable. Angio-FFR (VIRTUheart™) was computed using previously described methods. Three simulations were run: using a generic CMVR value (Model A); using ML-predicted CMVR based upon simple clinical data (Model B); and using ML-predicted CMVR also incorporating echocardiographic data (Model C). The diagnostic (FFR ≤ or >0.80) and absolute accuracies of these models were compared. Eighty-four patients underwent coronary angiography with FFR assessment in 157 vessels. The mean measured FFR was 0.79 (±0.15). The diagnostic and absolute accuracies of each personalized model were: (A) 73% and ±0.10; (B) 81% and ±0.07; and (C) 89% and ±0.05, P < 0.001. The accuracy of angio-FFR was dependent in part upon CMVR estimation. Personalization of CMVR from standard clinical data resulted in a significant reduction in angio-FFR error. Clinical data and machine learning were utilized to improve the accuracy of angio-FFR. Data were collected from patients with chronic coronary syndromes and undergoing coronary angiography. Fractional flow reserve assessment, combined with computational fluid dynamics modelling, was utilized to determine the vessel-specific coronary microvascular resistance (CMVR). Other clinical and transthoracic echocardiographic (TTE) data were entered into a machine learning model to identify predictors of CMVR. Two models were created, the first incorporating basic clinical data (Model B) and the second incorporating TTE data. Model-predicted CMVR was then incorporated in vFFR computation. Both personalized models were compared with the standard vFFR method (Model A). Diagnostic accuracy increased on account of model personalization (Model A = 73%, Model B = 81%, Model C = 89%). CFD, computational fluid dynamics; CMVR, coronary microvascular resistance; FFR, fractional flow reserve; vFFR, virtual (angio-)fractional flow reserve.

3 October 2018 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
YSYubing Shi
Yubing Shi
PLPatricia Lawford
Patricia Lawford
DHD. Rodney Hose
D. Rodney Hose
Lumped-parameter models are widely used by cardiovascular researchers in the analysis of the circulatory dynamics. However, portability and model exchange have always been a problem, with different researchers implement the model differently. To improve the situation, in this study, a group of lumped-parameter cardiovascular system models with different levels of complexity have been implemented using the CellML mark-up language. The models have been curated and made publicly available in the CellML model repository, and the purpose of this paper is to provide further technical details to support the usage of these models by the research community. The developed models are validated and tested under the OpenCell environment as part of the curation process. Simulation results agree well with typical published data on cardiovascular system response.

25 May 2021 in Journal of Biological Physics
Verified
Journal Article
Open access
PDF file
YSYubing Shi
Yubing Shi
IVIsrael Valverde
Israel Valverde
PLPatricia V. Lawford
Patricia V. Lawford
HGHeynric B. Grotenhuis
Heynric B. Grotenhuis
PBPhilipp Beerbaum
Philipp Beerbaum
DHD. Rodney Hose
D. Rodney Hose
Non-invasive estimation of the pressure gradient in cardiovascular stenosis has much clinical importance in assisting the diagnosis and treatment of stenotic diseases. In this research, a systematic comparison is conducted to investigate the accuracy of a group of stenosis models against the MRI- and catheter-measured patient data under the aortic coarctation condition. Eight analytical stenosis models, including six from the literature and two proposed in this study, are investigated to examine their prediction accuracy against the clinical data. The two improved models proposed in this study consider comprehensively the Poiseuille loss, the Bernoulli loss in its exact form, and the entrance effect, of the blood flow. Comparison of the results shows that one of the proposed models demonstrates a cycle-averaged mean prediction error of −0.15 ± 3.03 mmHg, a peak-to-peak prediction error of −1.8 ± 6.89 mmHg, which is the best among the models studied.