Suzanne A. Maher

Suzanne A. Maher

Auto-generated profile, based on publicly available information

Suzanne A. Maher

Department of Biomechanics, Hospital for Special Surgery, New York, NY, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
ABAsheesh Bedi
Asheesh Bedi
NKNatalie Kelly
Natalie Kelly
MBMichael Baad
Michael Baad
AFAlice Js Fox
Alice Js Fox
RBRobert H Brophy
Robert H Brophy
SMSuzanne A Maher
Suzanne A Maher
Were that (1) there is a threshold size of radial tears above which contact mechanics are adversely affected, and (2) partial meniscectomy results in increased contact pressure compared with that found after meniscal repair. Methods: A knee simulator was used to apply physiological multidirectional dynamic gait loads across human cadaver knees. A sensor inserted below the medial meniscus recorded contact pressures in association with (1) an intact meniscus, (2) a radial tear involving 30% of the meniscal rim width, (3) a radial tear involving 60% of the width, (4) a radial tear involving 90% of the width, (5) an inside-out repair with horizontal mattress sutures, and (6) a partial meniscectomy. The effects of these different types of meniscal manipulation on the magnitude and location of the peak contact pressure were assessed at 14% and 45% of the gait cycle. Results: The peak tibial contact pressure in the intact knees was 6 ± 0.5 MPa and 7.4 ± 0.6 MPa at 14% and 45% of the gait cycle, respectively. The magnitude and location of the peak contact pressure were not affected by radial tears involving up to 60% of the meniscal rim width. Radial tears involving 90% resulted in a posterocentral shift in peak-pressure location manifested by an increase in pressure in that quadrant of 1.3 ± 0.5 MPa at 14% of the gait cycle relative to the intact condition. Inside-out mattress suture repair of a 90% tear did not restore the location of the pressure peak to that of the intact knee. Partial meniscectomy led to a further increase in contact pressure in the posterocentral quadrant of 1.4 ± 0.7 MPa at 14% of the gait cycle. Conclusions: Large radial tears of the medial meniscus are not functionally equivalent to meniscectomies; the residual meniscus continues to provide some load transmission and distribution functions across the joint. Clinical Relevance: The results of this study support meniscal preservation and repair of medial radial tears....

1 June 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
SGSusannah Gilbert
Susannah Gilbert
TCTony Chen
Tony Chen
IHIan D. Hutchinson
Ian D. Hutchinson
DCDan Choi
Dan Choi
CVClifford Voigt
Clifford Voigt
SMSuzanne A. Maher
Suzanne A. Maher

20 September 2010 in Arthroscopy
Verified
Journal Article
Closed access
SMSuzanne A. Maher
Suzanne A. Maher
SRScott A. Rodeo
Scott A. Rodeo
SDStephen B. Doty
Stephen B. Doty
RBRobert Brophy
Robert Brophy
HPHollis Potter
Hollis Potter
RWRussell F. Warren
Russell F. Warren

28 April 2014 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
HWHongsheng Wang
Hongsheng Wang
AGAlbert O. Gee
Albert O. Gee
IHIan D. Hutchinson
Ian D. Hutchinson
KSKirsten Stoner
Kirsten Stoner
RWRussell F. Warren
Russell F. Warren
SMSuzanne A. Maher
Suzanne A. Maher
Background: Meniscus allograft transplantation (MAT) is primarily undertaken to relieve the symptoms associated with meniscal deficiencies. However, its ability to restore normal knee joint contact mechanics under physiological loads is still unclear. Purpose: To quantify the dynamic contact mechanics associated with 2 commonly used fixation techniques in MAT of the medial compartment: transosseous suture fixation via bone plugs and suture-only fixation at the horns. Study Design: Controlled laboratory study. Methods: Physiological loads to mimic gait were applied across 7 human cadaveric knees on a simulator. A sensor placed on the medial tibial plateau recorded dynamic contact stresses under the following conditions: (1) intact meniscus, (2) MAT using transosseous suture fixation via bone plugs at the anterior and posterior horns, (3) MAT using suture-only fixation, and (4) total medial meniscectomy. A “remove-replace” procedure was performed to place the same autograft for both MAT conditions to minimize the variability in graft size, geometry, and material property and to isolate the effects of the fixation technique. Contact stress, contact area, and weighted center of contact stress (WCoCS) were quantified on the medial plateau throughout the stance phase. Results: Knee joint contact mechanics were sensitive to the meniscal condition primarily during the first half of the gait cycle. After meniscectomy, the mean peak contact stress increased from 4.2 ± 1.2 MPa to 6.2 ± 1.0 MPa ( P = .04), and the mean contact area decreased from 546 ± 132 mm 2 to 192 ± 122 mm 2 ( P = .01) compared with the intact meniscus during early stance (14% of the gait cycle). After MAT, the mean contact stress significantly decreased with bone plug fixation (5.0 ± 0.7 MPa) but not with suture-only fixation (5.9 ± 0.7 MPa). Both fixation techniques partially restored the contact area, but bone plug fixation restored it closer to the intact condition. The location of WCoCS in the central cartilage region (not covered by the meniscus) shifted peripherally throughout the stance phase. Bone plug fixation exhibited correction to this peripheral offset, but suture-only fixation did not. Conclusion: Under dynamic loading, transosseous fixation at the meniscal horns provides superior load distribution at the involved knee compartment after meniscal transplantation compared with suture-only fixation. Particular attention should be directed to the ability of medial MAT to function during the early stance phase. Clinical Relevance: Transosseous fixation via bone plugs provides superior load distribution of a transplanted meniscal allograft compared with suture fixation alone at time zero.

27 March 2007 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
SMS.A. Maher
S.A. Maher
SDS.B. Doty
S.B. Doty
PTP.A. Torzilli
P.A. Torzilli
STS. Thornton
S. Thornton
ALA.M. Lowman
A.M. Lowman
EME. Myers
E. Myers

1 January 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
HWHongsheng Wang
Hongsheng Wang
TCTony Chen
Tony Chen
PTPeter Torzilli
Peter Torzilli
RWRussell Warren
Russell Warren
SMSuzanne Maher
Suzanne Maher