Bohumír Zaťko

Bohumír Zaťko

Auto-generated profile, based on publicly available information

Bohumír Zaťko

Institute of Electrical Engineering, Slovak Academy of Sciences, Dúbravská cesta 9, SK-841 04 Bratislava, Slovak Republic

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
BZB. Zaťko
B. Zaťko
AŠA. Šagátová
A. Šagátová
KSK. Sedlačková
K. Sedlačková
PBP. Boháček
P. Boháček
MSM. Sekáčová
M. Sekáčová
VNV. Nečas
V. Nečas

1 March 2022 in Materials Science in Semiconductor Processing
Verified
Journal Article
Closed access
JOJ. Osvald
J. Osvald
LHL. Hrubčín
L. Hrubčín
BZB. Zaťko
B. Zaťko

5 January 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
KSKatarína Sedlačková
Katarína Sedlačková
BZBohumír Zaťko
Bohumír Zaťko
AŠAndrea Šagátová
Andrea Šagátová
VNVladimír Nečas
Vladimír Nečas

1 January 2024 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
BZBohumír Zaťko
Bohumír Zaťko
MVMarián Varga
Marián Varga
GVGabriel Vanko
Gabriel Vanko
TITibor Izsák
Tibor Izsák
AŠAndrea Šagátová
Andrea Šagátová
AKAlexander Kromka
Alexander Kromka
In this work, the radiation detector structures based on polycrystalline diamond film have been studied. Polycrystalline chemical vapor deposited diamond film on silicon substrate has a thickness of about 3 µm. The Ti/Au double layer was used to prepare the circular electrical contacts of 1 mm in diameter on the top of diamond layer. The back side was covered by the full area contact. The current-voltage characteristics of the prepared samples in both directions were measured at room temperature up to 50 V with the flowing current below 0.1 nA. The samples were then connected to the spectrometric chain and used for α-particle detection generated from 241Am. The range of α-particles in detector structure is 27 µm. The detectors were operated at zero bias and show a relative energy resolution of 12% for α-particles with energy of 5.5 MeV.

1 November 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
BZBohumír Zaťko
Bohumír Zaťko
MVMarián Varga
Marián Varga
EKEva Kováčová
Eva Kováčová
AŠAndrea Šagátová
Andrea Šagátová
The diamond radiation detector was prepared using a high-quality monocrystalline substrate. A square contact of 3.6 × 3.6 mm2 was fabricated on one side of the substrate, while the other side has a full area metallized contact. The current-voltage characteristics were measured up to 1 kV in both directions. The fabricated diamond detector shows very low current below 2 pA in whole voltage ranges. The detector was then used for alpha particle detection. The triple radiation source was used with different monoenergetic particles with energies varying from 5.1 MeV to 5.8 MeV. The range of alpha particles used was no more than 15 μm according to SRIM simulations. The diamond detector shows a high resolution for alpha particle spectroscopy below 0.43% at 5.5 MeV energy.

1 October 2005 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
BZB. Zaťko
B. Zaťko
FDF. Dubecký
F. Dubecký
PŠP. Ščepko
P. Ščepko
VMV. Melov
V. Melov
MHM. Herms
M. Herms
LHL. Haupt
L. Haupt